}

Tender For Provision Of Ei, Fans And Compound Lights In Newly Constructed Je Office In Ward No. 113 Mohan Garden Under West Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Provision Of Ei, Fans And Compound Lights In Newly Constructed Je Office In Ward No. 113 Mohan Garden Under West Zone.. Submission Date for this Tender is 21-11-2023. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40650910
Tender For Provision Of Ei, Fans And Compound Lights In Newly Constructed Je Office In Ward No. 113 Mohan Garden Under West Zone.
Open Tender
NCB
Delhi
Delhi
21-11-2023

Tender Details

Tender For Provision Of Ei, Fans And Compound Lights In Newly Constructed Je Office In Ward No. 113 Mohan Garden Under West Zone.; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C 2 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x2.5 Sq.Mm+1X2.5 Sq.Mm Earth Wire 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X4sq.Mm+1X4 Sq.Mm Earth Wire 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required4x4 Sq.Mm+ 2X4 Sq.Mm Earth Wire 5 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 6 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch 7 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Out Let 8 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way Double Door 9 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 10 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps 11 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep 12 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm 13 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 14 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. Without Charcoal / Coke And Salt As Required. 15 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 16 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 17 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 18 Providing And Fixing Circular / Hexagonal Cast Iron Of Ms Sheet Box For Ceiling Fan Clamp Of Internal Dia 140Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick Ms Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron / Ms Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners, Clamp Shall Be Mad Eof 12 Mm Dia Md Bar Bent To Shape As Per Standard Drawing. 19 Supply Of 12 ( 300M ) Sweep 1400 Rpm Exhaust Fan Heavy Duty Complete With Shutter, Blade Etc As Required 20 Supply, Installation, Testing And Commissioning Ofsingle / Threephase Mono Block P / Set Complete With All Accessories Workable On 240 / 415 Volt. 50 Hz Ac Supply . ( A ) 1Hp ( 0.75 Kw ) Single Phase Pump Set Head Frame 12.5 Mt Upto 25 Mt Suction And Delivery 25X25 21 Supply Ofxlpe Insulated, Pvc Sheathed Al.Conductor Armoured Cable 1.1 Kvgrade Conforming To Is 7098Of Following Sizes 2 X 6 Sq Mm 22 S / I / T / Cof Led Tubetype Luminaire20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt+ / -5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 23 Sitc Of 60W Led Flood Light Luminiare Fitted With , Lens, Made Of Pressure Die Cast Aluminium Housing & Halonix Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =60 Watt+ / -5% ( B ) Luminaire Efficacy>=Lo0 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 24 P / F Of Hot Press Sheed Moulded Compound ( Smc ) Fireretardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Pole Box Of Inner Dimension 200Xl60x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nos Of 6 To 32 Amp Single Pole Mcb & 63 Amp. Double Pole Isolator ( Mcb / Lsolator Excluded ) With Neutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With 55 Back Plate Of Suitable Size With Danger Monogram Property Printed On The Cover Etc As Reqd. As Reqd.

Key Value

Document Fees
INR 590 /-
EMD
INR 1950.0 /-
Tender Value
INR 90925.0 /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail