}

Tender For Addition/Alteration To Bldg. No P-337 At Afs Yelahanka, yelahanka-Karnataka

Military Engineer Services has published Tender For Addition/Alteration To Bldg. No P-337 At Afs Yelahanka. Submission Date for this Tender is 09-12-2023. Road Work Tenders in yelahanka Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40629097
Corrigendum : Tender For Addition/Alteration To Bldg. No P-337 At Afs Yelahanka
Open Tender
Indian
Karnataka
Yelahanka
09-12-2023

Tender Details

Tender For Addition / Alteration To Bldg. No P-337 At Afs Yelahanka; 1 Surface Dressing N.Exc 15 Cm Deep Andgetting Out In Soft / Loose Soilall As Directed. 2 Excavationin Trenchs Not Exceding1.5 M Wide & Depth For Foundation Etc Or For Shaft, Wells, Etc And N. Exc 10 Sqm On Plan And N.Exc 1.5M In Depth & Getting Out In Soft / Loose Soil Complete All As Directed. 3 All As Per Item No 2 Above Butdepth Exc 1.5Mtr And N Exc 3M And Getteing Outin Soft / Loose Soil Complete All As Specified And Directed. 4 Returning Filling In , Including Spreading , Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Complete All As Directed 5 Removing Of Excavated Surplus Soil Not Exceeding 50M Lead And Depositing Where As Directed At A Level Not Exceeding 1.5M Above The Staring Point Complete All As Directed. 6 M & L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidationcomplete All As Specified And Directed. 7 M&L For Plain Cement Concrete Type D-2, 1:4:8 ( Using 40Mm Graded Stone Aggregate ) In Foundation, Filling & Mass Concrete Complete All As Specified And Directed. 8 M / L For Precast Cement Concretetype B1 1:2:4 ( Using 20 Mm Graded Aggregate ) Blockmasonary With Solid Blocks Exc 10Cm In Width And Setting In Cm 1:6 Complete All As Specified And Directed. 9 M&L For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With The Including Mild Steel Wire ( Annealed ) Not Less Than 0.90 Mm Dia Or Securing Complete All As Specified And Directed. 10 All As Per Item Ser No 9 As Above But 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders Complete All As Specified And Directed. 11 M&L For Use And Waste Of Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter And Finished Concrete Flat Complete All As Specified And Directed. 12 M&L For Use And Waste Of Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns, And Stanchions And Finishedrough Surfaces Of Concrete Flat Complete All As Specified And Directed. 13 M&L For Use And Waste Of Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc And Finishedrough Surfaces Of Concrete Flat Complete All Specified And Directed. 14 M&L For Use And Waste Offormwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) Complete All As Specified And Directed. 15 M&L For Reinforced Cement Concrete M-25 Grade ( Design Mix ) , ( Using 20Mm Graded Stone Aggregate ) In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under Reamed Piles And Mass Concrete Complete All As Specified And Directed. 16 M&L For Reinforced Cement Concrete M-25 ( Design Mix ) With Using 20Mm Graded Stone Aggincolumns, Pillars, Piers, Posts And Struts Complete All As Specified And Directed. 17 M&L For Reinforced Cement Concrete M-25 ( Design Mix ) , ( Using 20Mm Graded Stone Aggregate ) Inbeams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And Directed.. 18 M&L Reinforced Cement Concrete Slabs Supported On Walls In M-25 ( Design Mix ) , ( Using 20 Mm Graded Stone Agregate ) , Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And Directed. 19 M&L 15Mm Thick Cement Plaster In Cm 1:4 On Brick Work Or Concrete Surfaces Renderingis To Be Even & Smooth Without Using Extra Cement On External Wall Complete All As Specified And Directed. 20 M&L For Preparation Of The New Surfaces Of Walls Plastered , And Applyingtwo Cots Of Weather Proof Paint ( Apex ) Over A Coat Of Primer , Complete All As Specified And As Directed. 21 M & L For Rendering 15Mm Thick In Cm 1:6 Onbrick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 22 M&L For Preparation Of New Wall Surface And Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerSspecification. Two Or More Coats On New Work Complete All As Specified And Directed. 23 M&L For Rendering 5 Mm Thick Onconcrete Surfaces As In Ceiling In Cement Mortar ( 1:3 ) All As Specified And Directed. 24 M&L For Preparation Of New Ceiling Surface And Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerSspecification. Two Or More Coats On New Work Complete All As Specified And Directed. 25 M&L For Hardcore ( Broken Stone Or Boulders ) Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed. 26 M&L For 75Mm Thick, Plain Cement Concrete, Type D-21:4:8, ( Using 40 Mm Graded Stone Aggregate ) As In Sub Base Of Floor Complete All As Specified And Directed. 27 M&Lfor 75 Mm Thick Plain Cement Concretetype B-2, 1:2:4 ( 40 Mm Graded Stone Aggregate ) For Plinth Protection Including Necessary Formwork Complete All As Specified And Directed. 28 S&F Powder Coated Anodised Aluminium Frame And Shutters With All Fixing Arrangementsfor Doors, Windows Andventilators With One Or More Rebates Including Joing Cleat For Fixing Etc Aluminium Section Of Powder Coating Not Less Than 50 Micron All As Specified And Directed. 29 S&F Powder Coated Aluminium Door / Windows / Ventiliator Shutters Aluminium Section Weighing 0.55Kg / M Including Necessary Joining, Fixed Type, Cleats, Glazing Clips, Rubber Neoprene Packing, Roller In Each Window, Anodised Alumnium Snap Beading, Screw Etc, Complete All As Specified And Directed.Note : Powder Coating Shall Not Less Than 50 Micron 30 M&L Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Single Side Prelam Pvc Sheetused Instead Of Plain Colour Pvc Sheet & Edges Will Be Painted To Match With Prelam Sheet All As Specified And Directed. 31 M&L Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core 28 To 30 Mm Thick ( Stiles ) , With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Prelam Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face Including Neccessary Fitiings Etc Complete As Specified And Directed. 32 S&F Butt Hinges Of Size 100Mm Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised And Fixed, Type C-21 All As Specified And Directed. 33 S&F Mild Steel Mortice Lock 4 Levers , Vertical Type, Size 100 Mm Complete All As Specified And Directed. 34 S&F Of Aluminium Anodised, Barrel Tower Bolt 150Mm Long Of Extruded Section Complete All As Specified And Directed. 35 S&Faluminium Handle Of Size Of 150Mm Cast Type Anodised Complete All As Specified And Directed. 36 S&F Sheet Glass Ordinary Quality 4.80 Mm Thick As In Doors, Window, Showcase Alum Frame Work & Similar Work With Or Without Glass Roller In Square N Exc 0.5 Sqm Each Including Neoprime Gasketall As Directed By Engineer-In-Charge 37 All As Per Item 36 Above But 4 Mm Thick Figured Glass Pin Head Type Complete All As Specified And Directed. 38 S&F 9 Mm Thick Prelaminated Particle Board, Exterior Grade, Prelaminated One Side With Decorative Choice Lamination & Other Side Balancing White Lamination, Fixed With Screws To Timber Frame / Aluminium Work All As Specified And Directed. 39 M & L 18 / 19 Mm Thick Block Boards, Grade 2 Quality, Interior Grade, Decorative Type With Decorative Face Veneer On Both Face Fixed All As Specified And Directed. 40 S&F Continuous ( Piano ) Hinges, Brass , Bright Finish Of Electrogalvanised 40 Mm Width Of Flap Complete All As Specified And Dircted. 41 M&L For Cover Fillets Of Standard 6 Mm Thickness Hard Board, 40Mm Wide, And Fixing With Screws Complete All As Specified And Directed. 42 S & F Mild Steel Framed Work As Ingrills Conforming To Fe 290 Gde E-165 Complete All As Specified And Directed. 43 M&Lfor Double Action Floor Spring Hydraulically Regulated Made Up Of Minimum 1.25 Mm Thick Aluminium Alloy Sheet Foundation Box, Main Body With Stainless Steel Cover, Governing Pivot Made Of Brass, Other Parts Made Of Mild Steel Heavy Duty Complete All As Specified And Directed. 44 M& L For Preparation Of New Steel Surfaces Of Any Description Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Emanelpaint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed. 45 M&Lfor Glazed Coloured Ceramictiles Of Size 450X350x7mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Matchas In Vertical Surface Including 10 Mm Thick Back Coat. In Cm 1:4 Finished All As Specified And Directed. 46 M&L For Non Skid Coloured Ceramic Tiles 7 To 8 Mm Thickmatt Finish ( Square / Rectangular ) Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm, In Floors Etc, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With Tile Incl Screedd Bed 15 Mm Thick In Cm ( 1:6 ) Complete All As Directedand Specified. 47 M&L For Vitrified Ceramic Light Shade Tiles Double Chargedof 10Mm Thick And Area Of Each Tiles Exceeding 0.42 Sqm But N Exc 1.00 Sqm For Flooring Including 15 Mm Thick Screed Bed In Cm 1:6All As Specified And Directed. 48 M&L Vitrified Ceramic Light Shade Tiles Double Chargedof 10Mm Thick And Area Of Each Tiles Exceeding 0.42 Sqm But N Exe 1 Sqmm As In Skirting / Dado Including 10 Mm Thick Backing Coatin Cm 1:4 All As Specified And Directed. 49 S&Fvitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) , White Premium Quality ( Excluding Fixing Bolts, Flushing Cistern And Flush Pipe ) All As Specified And Directed. 50 S&F Plastic Pedestal Pattern Seat Cover With Flat Bottom And Cover And Ms Chormium Plated Hanging Type Device All As Specified And Directed. 51 S&F 10 Litre Capacity Pvc Syphonic Action Type For Low Level Flushing Cistern Including All Fittings And Including Flushing Pipe Fixed All As Specified And As Directed. 52 S&F Vitreous China Urinal , Half Stall Type, With All Necessary Fitting Complete All As Specified & Directed. 53 S&Fvitreous China Wash Basin, White Or Coloured Of Size 550 X 400 Mmwith Padestal Including Brackets And Fixing Of Pillar Tap All As Specified And As Directed . 54 S & F Pillar Tap 15Mm Bore Fancy Type Chromium Plated, With Capstan Head Screwed Down High Pressure With Or Without Lettered “Hot Or Cold” With Long Screwed Shanks Fly Nuts , Screwed For Iron Pipeand Fixed Completed All As Specified. 55 S&F 600X450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. 56 S&F Chromium Plated Towel Rail 600 Mm Long Fixed With Chromium Plated Brass Screws And Wooden / Plastic Cleats Complete All As Specified And Directed. 57 S&Fchromium Plated Health Fauccet Of Including Neccessary Holding Arrangements With Screws Etc All As Specified And Directed By The Engineer -In -Charge. 58 S&F In Repair Bib Taps Chromium Plated 15 Mm With Fancy Type With Capstan Head Handle Screwed Both Ends For Iron Pipe Or For Union Complete All As Specified. 59 S&F 15Mm Dia Angle Valves, Cast Copper Alloy, Cp, Screwed Down, High Pre-Ssure, With Crutch, Screwed Both Ends For Iron Pipe Or For Unionscomplete All As Specified And Directed. 60 S & F In Repairs Pvc Connection 15Mm Size With Ptmt Nut Of Length 600Mm Etc Complete All As Specified And As Directed . 61 S & F Of 32Mm Waste Pipe For Wash Hand Basin And Sink All As Specified And As Directed 62 S&F Cp Grating Size 100Mm Fixed With White Cement All As Specified And Directed 63 S&F Stainless Steel Soap Dish Fix To Wall All As Specified And Directed. 64 S&F Paper Holder With Flap Recessed Type ( Stainless Steel ) All As Specified And Directed By Engr-In-Charge. 65 S&F Cpvc Pipes20 Mm Sdr 11 & Plain Cpvc Sdr 11 On Walls, Ceiling Including Fitting Complete All As Specified And As Directed By Engr In Charge. 66 S&F Cpvc Pipes25 Mm Sdr 11 & Plain Cpvc Sdr 11 On Walls, Ceiling Including Fitting Complete All As Specified And As Directed By Engr In Charge. 67 S&Fspvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall ( 110 Mm Bore ) Including Flat Iron Claim For Proper Fixing Complete All As Specified & Directed By Engr-In-Charge. 68 S&F Pvc ( Swr ) Bends 110Mm Dia Complete All As Specified & Directed By Engr-In-Charge. 69 S&Fpvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall ( 75 Mm Bore ) Including Flat Iron Claim For Proper Fixing Complete All As Specified & Directed By Engr-In-Charge. 70 S&Fpvc ( Swr ) Bends 75Mm Dia Complete All As Specified & Directed By Engr-In-Charge. 71 S&F Pvc Floor Trap 75Mm Dia, Including Jointing To Waste Pipe Fixed In Cement Concrete Type B1 ( 1:2:4 ) Complete All As Specified And Directed. 72 Material And Labour For Rendering 15Mm Thick ( Average ) Incement Mortar 1:4 On Roof Surfaces Mixed With Water Proofing Compound As Per ManufacturerS Instructions, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed.Note:- Supply Only Of Water Proofing Compound Will Be Measured And Paid Seperately Under Relevant Item 73 Supply Only Approved Liquid Water Proofing Compound Complete All As Specified And Directed. 74 M&L Applying Oil Bounded Bitumen Primer @ 0.20 Kg / Sqm, And Providing 4Mm Thick App Modified Water Proofing Membrane Weighing Not Less Then 4.0 Kg / Sqm, Reinforced With Non Woven Polyester Matt Weighing Not Less Then 160 Gm / Sqm Having Softening Point Not Less Then 150 Degree Centigrade, Having Tensile Strength Of 650 N / 5 Cm And 350 N / 5Cm In Longitudinal And Transverse Directions Respectively Of The Reinforcement, Trearing Strength Of 180 N By Torch- On Application Including Min 10Cm Side Over Lap & 15 Cm End Laps.Applying A Coat Of Blown Grade Hot Bitumen 90 / 15 Over The Membrane @ 1.2 Kg / Sqm As Per The Detailed Specifications.Note:The Laying / Applying Of App Membrane And Other Connected Work Shall Be Carried Out By The Approved Applicator Of The Manufacturing Company Of App Membrane. 75 S&F Rotational Moulded Polyethylene Water Storage Tank 1000 Ltr Capacity Incl Threaded Type Cover Hoisted And Fixed In Position Complete All As Specified And Directed. 76 S&F 25 Mm Boreball Valves High Pressure Of Ptmt Withepoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Complete All As Specified And Directed. 77 S&F Ptmt Nipple 20 Mm Suitable For Hdpe Water Tank. ( Minimum Weight 20Mm- 45Gms ) Complete All As Specified And Directed. 78 S&F 20Mm Bore Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixedcomplete All As Specified And Directed. 79 All As Per Item No 78 Above But 25Mm Borecomplete All As Specified And Directed. 80 S& F For Aluminium Powder Coated Drapery Rod 32Mm Dia Fixed With Suitable Bracket Complete All As Specified And Directed. ( Note: Bracket Will Be Measured And Paid Separately ) . 81 S& F Aluminium Powder Coatedfancy Type Suitabe Brackets Fixed Atboth Endsof Openings Fixed Over 1St Class Hard Wood Rounded Wooden Blocks 0F 65Mm Dia And 20Mm Thick Fixed To Stone Wall / Brick Wall Using Screws Inclnecesary Drilling & Finished With Polishingeach Opening Shall Have Two Fillets At Both Ends Complete All As Specified And Directed. 82 M & L For Providing And Injecting Chemical Emultion For Post Construction Antitermite Along The Externalof Wall Below Concrete Or Masonary Apron Using Chemical Emultion At The Rate Of2.25 Litre Per Linear Meter Including Drilling And Pluging Holes Etc Complete All As Specified And Directed. 83 M&L For 20Mm Thickgranite ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs Pillar Window Cill, Coocking Plot Forms And Including 20Mm Thick Cement Mortar ( 1:4 ) Incl Pointing In White Cement ( Tiles 20Mm Thick Machine Cut, Bedded And ;Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone ( I ) Using Morble Dust With Admiture Of Pigment To Match Incl Rounding To Edges Of Granite Slab Such As Cooking Platform All As Specified And Directed. 84 Excavating In Post Holes ( Or Similar Holes ) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface Complete All As Specified And Directed. 85 S&F Mild Steel Tubular Trusses Including Special Shaped Washer Framed Work Such As In Doors Or Gate Of Angle Or Other Section With Gusset Plates, Braces Etc. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes, Framed Guard Bars , Barred Iron Dooetc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To Is 1161-1979 Grade St-240 Complete All As Specified And Directed. 86 S&F 0.50 Mm Thick Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated / Plain Steel Sheet Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screwscomplete All As Specified And Directed. 87 M&Lfor Concrete Bed To Drain Pipes In Pcc 1:4:8 Type C2 Using 40Mm Graded Stone Aggregate Including Packing Under And Haunching Against Sides Of Pipes After They Are Laid And Tested For 150Mm Dia Pipe Complete All As Specified And Directed. 88 M&L For Reinforced Concrete Pipes, Class Np2, 150Mm Dia Laid And Jointed Complete With Collars All As Specified And Directed. 89 M&L Plain Cement Concrete 1:2:4 Type B1 Using 20Mm Graded Stone Aggregate As Incoping / Benching Of Manholesincluding Eatherlng, Rounded / Chemfered Angles And Throating As Directed Including Necessary Form Work And Finishing All Exposed Surfaces Of Concrete Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 90 M&L For Precast Rcc Cover Slabs For Manholes 1:2:4, Type B1, Using 20Mm Gradedstone Aggregates, Set In Cm 1:4 Including Necessary Form Work And Finishing The Exposed Surfaces Of Concrete Even And Smooth Without Using Extra Cement Complete All As Specified. 91 S&F Mild Steel Tmt Bars 6 To 8Mm Dia, Cut To Length Bent To Shape Requried Including Cracking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steelwire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips All As Specified And As Directed. 92 M & L For Cutting Into Existing Manholes 150Mm Dia For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel ( 1 / 2 Round Or 3 / 4 Section ) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required Complete All As Specified And Directed. 93 Surface Excavation N.Exc ( Not Exceeding ) 30 Cm Deep And Averaging 15 Cm Deep And Getting Out Soft And Loose Soil Complete All As Specified And Directed. 94 Dismantling Floor, Hearth Or Wall Tiling Including Paver Block, Cement Mortar Bedding ( But Not Backing ) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 95 S & F Machine Pressed Rubber Moulded Coloured Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness , M 35 Grade With Grey Cement And Pigment Bedded And Laid Over And Including50 Mm Thick Sand Cushion Compacted And Joint Filled As Specified And Directed 96 Laying Only Machine Pressed Rubber Moulded Coloured Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness , M 35 Grade With Grey Cement And Pigment Bedded And Laid Over And Including50 Mm Thick Sand Cushion Compacted And Joint Filled As Specified And Directed Note :Servicable Dismantled Paver Block Obtained From Item No 94 Shall Be Used. 97 Point Wiring Completed With 1.5 Sqmm Single Core Pvcinsulated Heavy Duty Isi Marked Unsheathed Frlscopper Conductor Cable 1100 Volts Grade With Multistranded Copper Conductor Drawn Through Concealed Pvc Conduit And Including Provision Of Pvc Insulated Heavy Duty Isi Marked Unsheathed Copper Conductor, 1.5 Sqmm For Earth Continuity Conductor And Connected To Common Earth Dolly, Including Suitable Size Of Sheet Metal Box 1.6Mm Thickfixedand Flushed Inside Thewalls, With 3Mm Thick Laminated Sheet Top Cover For Housing The Switches, Socket Outlets, Fan Regulators Etc., Complete All As Specified And Directed For The Following : - 98 One Light / Ceiling Fan / Exhaust Fan / Ventilation Fan Point Controlled By One 5 Amps Switch 99 One Switch Socket Outlet Point 3 Pin 5 Amps On Same Board With Other Switches 100 One Three Pin Socket Outlet 5 Amp Controlled By One, One Way Switch On Independent Board Complete All As Specified And Directed By Engr-In-Charge. 101 All As Per Item No 97 Above Butwiring With 2.5 Sq Mm Frls Copper Cable Including Earth Continutyconductor With 2.5 Sq Mm Frls Copper Cable For One6 Pin 15 Amps Socket Outlet On Independent Board Controlled By 15 Amps Switch 102 Supply And Fix Switch Piano 5 Amps Flush Type One Way 103 Supply And Fix Socket Outlet 3 Pin 5 Amps Flush Type 104 Supply And Fix Switch Socket Combination 2 In 1, 3 Pin 5 Amps Flush Type 105 S&F Ceiling Rose, Three Terminal, Pvc / Polycarbonate, Isolated Body, Isi Marked 106 Supply And Fix Switch Socket Combination 3 Pin 16 Amps Multipin Flush Type Complete All As Specified And Directed By Engr-In-Charge. 107 Supply And Fixled Lights Fitting 20 Watt, 220V, 4 Feet Long, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed By Engr-In-Charge. 108 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current Motor ( Bldc ) Complete All As Specified And Directed By Engr-In-Charge. 109 Supply And Fix Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc For Ceiling Fan 1200 / 1400 Mm Sweep Complete All As Specified And Directed By Engr-In-Charge. 110 Supply And Fix Exhaust Fan 250Mm Sweep, Made Of Sturdy Engineering Plastic Complete With Louvers Shutter, Voltage 230V, 50 Hz, Rpm 1200, Copper Winding Complete All As Specified And Directed By Engr-In-Charge. 111 Supply And Fix Sheet Metal Enclosures Formcb Distribution Board 230 Voltssinglepole And Neutral 4 Way Double Door With 200 Amps Rated Bus Bar Complete Including Flushing The Dbs Inside The Wall And Making Good To The Disturbed Surfaces And Also Matching With The Existing Surface Complete All As Specified And Directed Byengr In Charge. 112 Supply Andfix Mcb Spn 32 Amps, 240 Volts, C Curve, 10 Ka Rupturing Capacity Complete All As Specified And Directed By Engr-In-Charge. 113 Supply Andfix Mcb Sp 6 To 32 Amps, 240 Volts, C Curve, 10 Ka Rupturing Capacity Complete All As Specified And Directed By Engr-In-Charge. 114 M & L For Earthing Complete With Galvanised Earth Plate Electrode Of Size 600X600x6 Mm Thick Burried Directly In Ground Earth Pit Not Less Than 2.25 M Below Ground Level With Top Edge Of Earth Plate Not Less Than 1.5 Mtrs Below Ground Level Connected To4 Mm Dia Gi Earth Wire As Earth Lead Upto A Length Of 7.5 Metre Long By Means Of Bolts, Nuts, Washers Etc. And Protected By Gi Pipe Light Grade 15Mm Dia And 20Mm Dia Gi Tubing Light Grade With Funnel For Watering, All As Shown In Electrical Plate No 3 Of Ssr Part-I, Back-Fill With Salt And Charcoal, Provision Of Test Point Including Connected To Earth Test Point And Necessary Earth Work Excavation In Any Type Of Soil Pcc ( 1:3:6 ) Type C1 Bed And Chamber Rcc ( 1:2:4 ) Type B1, Iron Grill Including Gi Cover With Hinge And Funnel Watering Pipe Etc Complete All As Specified And Directed By Engr-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Deep For Laying Of Cables, Pipes, Foundation For Poles Etc., And Getting Out In Hard / Dense Soil Complete All As Specified And Directed By Engr-In-Charge. 116 Supplying And Laying Brick Protection Cover On Cable With Sub Class B Brick, Laid Dry And Flat Adjacent To Each Other Complete All As Specified And Directed By Engr-In-Charge. 117 Returning Filling In Excavated Soil Upto A Depth Of 30 Cm After Riddling Of Excavated Soil ( In Lieu Of Sand ) For Cushioning Of Cable And Refilling Of Trenches With Left Over Normal Excavated Soil Including Spreading, Leveling, Watering And Well Ramming In Layers Complete All As Specified And As Directed By Engr-In-Charge. 118 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size Complete All As Specified And As Directed By Engr-In-Charge. 119 Supply, Fix & Testing Of Mccb In Existing Lt Panel Of Capacity 4 Pole Mccb 100 Amp, 50 Hz, 415 Vadjustable Type With Rupturing Capacity 16 Ka.Including Necessary Aluminium Lugs And Nut&Bolts Etc. For Connecting Up Of Ug Cable Size 35Sq Mm 3.5 Core And Complete All As Specified And As Directe By Engr-In-Charge. 120 Boring Of Holes Under Roof, Pavement, Hardstanding By Trenchless Technology Using Ultrasound Technique And Necessary Machine Including Hdpe Pipe Of 75Mm Dia Suitable For 0.4 Mpa Working Pressure Complete All As Specified And Directed By Engr-In-Charge. 121 Supply And Lay Gi Tubing Light Grade, 50Mm Dia In Trenches For Road Crossing / Laid In Floors Etc Complete All As Specified And Directed By Engr-In-Charge. 122 Cutting Existing 40Mm Borewater Mains And Inserting Tee 40 Mm X 25Mmfor Taking Branch Connection Including Fittings And Joints Complete All As Specifiedand Directed By Engineer-In-Charge. 123 Supply And Lay Pipe Galvanized, “Medium Class”, Including Fittings 25 Mm Dia Complete All As Specifiedand Directed By Engineer-In-Charge. 124 Supply And Fix Ppr Ball Valves ( Brass Insert ) Of 25 Mm Bore , High Pressure Of Ptmp With Epoxy Quoted Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixedcomplete All As Specifiedand Directed By Engineer-In-Charge. 125 Supply And Fix Valve, Stop, Screwed , 25 Mm ( 1” ) Dia And Fixing Up In Galvanized Iron Water Supply Mainscomplete All As Specifiedand Directed By Engineer-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-12-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-12-2023
2 18-11-2023 BOQ Corrigendum BOQ 02-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88360.0 /-
Tender Value
INR 44.18 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail