Tender For Round The Clock Operation And Maintenance Of E&M Services In Nit Delhi ; 1 Sh: 1 Operation & Maintenance Manpower 2 Round The Clock O&M Of Electrical And Mechnaical Services Of Main Campus Of Nit Delhi 3 Hvac 4 Operation &Maintenance [ Routine & Preventive ] And Break Down Maintenance Of Complete Air-Conditioning System Of The Building Having Window / Slip / Vrv System Comprising Of All The Machinery Like Ahus And Fcus / Outdoor Units Installed In Building, Vfds, Control Panel, Etc. For Their Proper Operation. 5 Fire Detection And Fire Fighting System 6 Maintenance Including Routine, Preventive And Break Down Maintenance And Daily Checking Of Fire Detection And Fire Fighting Systems Installed In Buildings Including Automatic Fire Alarm Panels, Detectors, Fire Pumps ( Main, Dg, Jockey ) , Entire Wet Riser And Sprinkler System Including All Hydrants, Hoses, Proper Operation Of Valves, And Other Portable Extinguishing System Periodical Testing And Checking And Mock Fire Drilling Etc. As Required. The Whole System Should Be Ready At All Times For Detecting Fire Incidence And Combating Fire By Use Of Pressurised Wet Riser System. 7 Maintenance Including Routine, Preventive And Break Down Maintenance And Daily Checking Of All Pressurisation & Mechanical Ventillation Fans Installed In Basement Or Elsewhere In The Building For Their Proper Operation At All Times, Vfds, Control Panel, Etc. As Required. 8 Electrical Substation & Power Distribution 9 Routine, Preventive And Break Down Maintenance Of Ht Sub Station Ensuring Proper Operation Of Transformers, Ht Switchgears, Lt Switchgears, All Distribution Panels, Monitoring Of Load. 10 Dg Set 11 Operation & Maintenance Of Dg Setsfor Proper Opeation Under Mains Power Failure To Provide Uninterrupted Power Supply In The Campus Including Cleaning Of Dg Set Periodically, Maintaing Log Book And Running Data Etc Complete As Required. 12 Day To Day Complaint And Fault & Manning / Operations Of Services 13 Attending Day To Day Complaints And Rectifications Faults Relating To All Sphere Of Electrical & Mechanical Activities Pertaining To The Entire Building And Periphery ( Compond Lights ) , Maintaing Of Record In Complaint Register, Repairing Register, Etc. Withnecessary Instruments / Tools For Measuring Voltage And Currents, Continuity, Megger, Etc. Shall Be Provided By The Contractor As And When Required. Tools, Plant, Machinery, Statationary, Uniform, & Other Miscllenous Item For Day To Day Maintenance, Etc Will Be In The Scope Of Contractor. 14 Deputation & Modality Of At-The-Site Worker 15 Providing Following Reserve Manpower For Manning, Operation, Attending Day To Day Complaints / Faults, Testing, Managing All E & M Activities Who Shall Be On Duty In The Building During The Whole Contract Period.1. Electrician / Wiremen - 5 No.2 Hvac Operator / Technician - 02 No. 3. Firemen- 01 Nos.4. Helper - 5 Nos.Total 13 Nos. 16 [ 1 Job Means -- Carrying Out The Scheduled Work By Providing The Above-Mentioned On-The-Spot Manpower And Fulfilling Terms & Conditions As Stipulated For A Period Of One Month 17 Total Sh: 1 Operation & Maintenance Manpower 18 Sh: 2 Annual Repair And Maintenance Work In Nit Delhi 19 The Items Taken From Chapter 1 ( Wiring ) 2 ( Mccb, Mcb & DbS ) , 5 ( Earthing ) , 7 ( Mv Cable Laying ) & 9 ( Mv Cable Jointing & End Termination ) In The Delhi Schedule Of Rates ( E&M ) 2022 20 Supplying And Fixing Of 15W Recess Mounting White / Yellowled Light Including Connection, Testing, Etc Complete As Required 21 Supplying And Fixing Of 150Mm Sweep, 25W Exhaust Fan Having Speed Of 1300Rpm &Air Delivery Of 275Cmm, Including Connection, Testing, Etc Complete As Required 22 Supplying And Fixing Of 400Mmwall Fan Having 1300Rpm Speed & Air Delivery Of 60Cmm, Including Connection, Testing, Etc Complete As Required 23 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 24 Supplying And Fixing Of 50 W, Ip Led Flood Light Including Connection, Testing, Etc Complete As Required 25 Supplying And Fixing Of 100W Ip Led Flood Light Including Connection, Testing, Etc Complete As Required 26 Supplying And Fixing Of 20 W Led Batten Light 4Ft Including Connection, Testing, Etc Complete As Required 27 Supplying And Fixing Of 20 W Led Bathroom Lightincluding Connection, Testing, Etc Complete As Required 28 Supplying And Fixing Of 36 W 6500K Led 2X2 Panel Including Connection, Testing, Etc Complete As Required 29 Supplying And Laying Of One Number 4X35 Sqmmpvc Insulated Xlpe Sheatheredaluminium Conductor, Armouned Cable Of 1.1Kv Grade On Surface / Cable Trayetc Complete As Required 30 Repairing And Rewinding Of Ceiling Fans With Super Enabled Copper Wire Of Assorted Makesincluding Varnishing , Overhauling, Replacement Of Ball Bearing Etc As Required 31 Supply And Fixing Of 36W Flourescent Tube Light On The Existing Batten Including Connection, Testing, Etc Complete As Required. 32 Supply And Fixing Of Ballast / Choke 36W Suitable For 36W Flourscent Tube Light Including Connection, Testing, Etc Complete As Required. 33 Supply And Fixing Of Starter Suitable For 36W Fluorescent Tube Light Including Connection, Testing, Etc Complete As Required.