Tender For Electrical Wiring For Blacksmith Workshop, Aus; 1 Supply And Laying Of Following Size Pvc / Xlpe Insulated And Pvc Sheathed 1.1 Kv Gsolid Aluminium Conductor Up To 10 Sq Mm Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Tape Inner Sheathed, Armour ( Extruded Pvc Type St2 Sheathed, 650 / 1100V Grade As Per Is 7908 ( Part 1 ) 1988 Armoured U.G. Cableu.G. Cable Laid In Ground / Partially In Air ( As Required For Termination Over Groundincluding Excavation Of Cable Trenchcushioning Etc Complete Handling Of Surplus Spoil, Debris Etto Proper Place As Specified And Directed By The Deptt. ( Nicco / Havells / Rpg / Cci / Polycab / Gloster / Finolex Make ) 3 & 1 / 2 Core A2xfy 2 25.00 Sq.Mm.3 & 1 / 2 Core Armoured U.G. Cable 3 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm. Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( Approved Make : Wires / Cables Rr Kable / Havells And Switch / Socket / Modularboards Havells / Legrand / L&T Or As Approved By Department ) 4 Group C 5 Wiring For Light / Power Plug With 2X4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Along With 1 Nos 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 6 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required ( Approved Make : Wires / Cables Rr Kable / Havells Or As Approved By Department ) 2X4 Sq. Mm + 4 Sq. Mm Earth Wire 7 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( Approved Make : Switch / Socket / Modularboards Havells / Legrand / L&T Or As Approved By Department ) 8 5 / 6 Amps Switch 9 15 / 16 Amp Switch 10 6 Pin 15 / 16 Amp Socket Outlet 11 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 12 8 Module ( 200Mmx150mm ) 13 4 Module ( 125Mmx75mm ) 14 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. ( Approved Make : Havells / Legrand / L&T Or As Approved By Department ) 15 8 Module 16 4 Module 17 Sitc 32 A 3 Pin, 4 Module Plug And Socket -Plastic Complete With Plastic Plug And 3 Pin Socket Outlet Ip 54, 32 A Mcb ( C Curve ) , Metal Mounting Box Complete As Directed By Department. ( Approved Make Havells / Legrand / L&T Or As Approved By Department ) 18 Sitc Of 70 W, 1400 Rpm, 300 Mm Exhaust Fanwith Metal Frame With Air Delivery Output >1700 Cfh ( Make: Havells / Bajaj / Crompton ) 19 Sitc Of 100 W, 450 Mm Wall Fan With Metal Frame And Button Control. ( Make: Havells / Bajaj / Crompton ) 20 Earthing With G.I.Earthpipe4.5Metrelong, 40Mmdia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 21 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 22 Sitc Dol Contact Starter For Operation Of Ac Units Complete With Required ( L&T / Havells / Legrand ) 2M Pvc Box, 2M Face And Base Plate Complete As Directed. ( Havells / Legrand / L&T ) 23 Sitc Of Led 18W Batten Lights Complete ( Make Havells / Bajaj / Crompton ) 24 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( Havells / Legrand / L&T ) 4 Way ( 4 + 12 ) , Double Door 25 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, CCurve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Havells / Legrand / L&T ) 26 Single Pole And Neutral 27 Single Pole 28 Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( Havells / Legrand / L&T ) 63 A Tp&N 29 Dismantling Of Existing Gi Street Light Pole And Reinstallation Of The Gi Pole On Cc Base With Required Cable Jointing And Reconnection Of Proper Operation Of The Gi Street Light Pole Complete As Directed