Supply, Installation, Testing, And Commissioning Of Fire Safety Measures And Equipments Along With Construction Of Under Ground Water Storage Tank 16Kl And Sitc Of 15Kva Dg Set At Chc Dharhal Rajouri.- 1 Providing, Laying, Testing & Commissioning Of B Class Heavy Duty Ms Pipe 100Mm Conforming To Is 3589 / Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete . 2 Providing, Laying, Testing & Commissioning Of B Class Heavy Duty Ms Pipe 80Mm Conforming To Is 3589 / Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges , Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required 3 Supplying And Fixing Single Headedhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 ( Type -A ) With Blank Gunmetal / Stainless Steel Cap And Chain As Required : Single Headed Gunmetal 4 Supplying, Fixing, Testing And Commissioning Of 80Mm Dia Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095. 5 Providing & Fitting 30Mtr. First Aid Hose Reel ( 1 No. On Each Block / Floor ) Conforming To Is 884 Along With Thermoplastic Hose As Per Is: 12585 And Gun Metal Globe Valve & Nozzle, Drum And Brackets For Fixing The Equipment On Wall, Connections From M.S Pipe With Stop Gun Metal Valve & M.S Pipe And Socket. 6 Providing & Fixing Controlled Percolation Fire Hose Pipe ( As Per Is:8423 ) Of 63Mm Dia And 15 Metre Length Rated For Brust Pressure Of 35.7Kg / Sqcm. The Hose Shall Be Tested For Flame Resistance Test In Accordance To Is:8423. Hose Shall Be Complete With Isi Marked Brass Male And Female Coupling ( Is:903 ) Bound & Riveted To Hose Pipe With Copper Rivets & 1.5Mm Copper Wire. 7 Supplying & Fixing 63Mm Dia Ss Branch Pipe With 20 Mm Dia Ss Nozzle Conforming To Is 903, Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required. 8 Providing & Fixing Weather Proof Hose Cabinets For Yard Hydrant, Fabricated From 16 G Ms Sheet With Full Glass Door And Locking Arrangement, Suitable To Accommodate One Hydrant Valve, 2 Nos. 15M Long Hose, 1 No. Branch Pipe And One Fireman’S Axe. The Cabinet Shall Be Painted With One Coat Of Primer And Finished Stove Enamelled “Fire Red”, “Fire Hose” Written On Front Including Suitably Mounted On A Raised Masonry Platform As Required. ( Approx 0.75Mx0.6Mx0.25M ) 9 Providing And Fitting Of 450 Ipm 7.5Hp Terrace Pressure Pump With Automatic Panel And Cable 4X10mm Ai Armored Cable 30Mtrs Along With Required Foundation ( The Pump Should Meet The Condition And Shall Be Gotten Approved By The Local Fire Authority ) . Cost Shall Be Inclusive For Approval Of System From Local Fire Authority And Any Other Relevant Statutory Authority At Initial And Various Other Stages Of Work, Including Preparation Of Report / Drawings As Per Fire Authority. 10 Providing And Fitting Of Poly-Ethylene Terrace Water Storage Tank Of Capacity2ki Is:12701 Marked With Cover And Locking Arrangement With Hole For Inlet, Outlet And Overflow Pipes With Base Support For Tank. 11 P / F Of Floor Indication Signage ( 25Cm X 30Cm ) Facing Flight And Landing Of Stairs, Exit Signage And Telephone No. Signage. 12 Fire Detection & Alarm Systemsupplying, Installation, Testing And Commissioning Of Microprocessor Based Intelligent Addressable Main Fire Alarm Two Loop Panel, Central Processing Unit With The Following Loopmodules And Capable Of Supporting Not Less Than 240 Devices ( Including Detectors ) And Minimum 120 Detectors Per Loop, Network Communication Card, Minimum 320 Character Graphics / Lcd Display With Touchscreen Or Other Keypad And Minimum 4000 Events History Login The Non Volatile Memory ( Eprom ) , Power Supply Unit ( 230± 5% V, 50 Hz ) , 48 Hrs Back-Up With 24 Volt Sealedmaintenance Free Batteries With Automatic Charger. Thepanel Shall Have Facility To Connect Printer To Printout Log Andfacility To Have Seamless Integration With Analog / Digital Voiceevacuation System ( Which Is Part Of The Schedule Of Workunder Sh: Pa System ) And Shall Be Complete With Allaccessories . The Panel Shall Be Compatible For Ibms Systemwith Open Protocol Bacnet / Modbus Over Ip Complete. 13 Supplying, Installation, Testing & Commissioning Of Intelligent Addressable Photo Thermal Detector Complete Withmounting Base Complete As Required. 14 Supplying, Installation, Testing & Commissioning Ofintelligent Addressable Programmable Sounder Complete Asrequired. 15 Supplying, Installation, Testing & Commissioning Ofaddressable Manual Call Point Complete As Required. 16 Supplying & Laying Of 2X1.5 Sq.Mm Copper Fire Alarm Armoured Cable, 600 / 1000V Rated With Annealed Copper Conductor Having Insulation, Steel Wire Armouring & Frls Outer Sheathcomplete As Required. 17 Providing & Fitting Of 9 Ltr. Capacity ( Is:940 ) Foam Fire Extinguisher ( Mechanical Type ) With Gun Metal Cap And Nozzle Complete For Wall Suspension Brackets. 18 Providing & Fitting Of 4.5 Kgcapacity Isi Mark ( Is:15683 ) Co2 Fire Extinguisher Suitable For “B” And “C” Class Fire. 19 Supplying, Installation, Testing And Commissioningof Ceiling Mountedautomated Modular Fire Suppression System ( Abc Map90 Powder Based ) - 10Kg Suitable For Class A, B, C And Electrically Started Fires. 20 Earth Work In Bulk Excavation By Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan ) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. ( Sch – 2.6 ) All Kinds Of Soil 21 Providing And Laying In Position Cement Concrete Of Specified Gate Excluding The Cost Of Centering Shuttering All Works Upto Plinth Level 1:3:6 ( One Cement: Three Coarse Sand: Six Nalla Stone Aggregate Of 40Mm Nominal Size ) . ( Sch – 4.4.5 ) 22 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts. ( Sch – 5.9.6 ) 23 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. Sch 5.2.2 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 24 Reinforcement Of Rcc Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Mild Steel And Medium Tensile Steel Bars Of Size 12Mm, 10Mm, 8Mm ( Including All Leads, Lifts And Carriages Etc ) . 25 15Mm Cement Plaster On The Rough Sides Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Fine Sand ) ( ( Sch – 13.2.1 ) 26 Providing, Installation, Testing And Commissioning Of B Class Ms Pipe 80Mm For Connecting To Water Tank And Fire Brigade Connection 27 Providing, Installation, Testing And Commissioning Of Nvr Valve 80Mm At Base Of Pipe Complete Set . 28 Sitcoffire Brigade Connection , 29 Sitc Of Flat Man Hole Cover 2Ftx2ft Heavy Duty. 30 Sitc Of Heavy Duty Single Phase Motor 3Hp Along Withrequired Cable , Starter For Power Connection And 60 Mtrs , 25Mmgi Pipe For Connection Up To Fire Tank At Roof Top . 31 Sitc Of 15 Kva Silent Dg Set Along With Amf Panel:Phase : 3, Power Factor :0.8 Laggingcooling Type: Liquid Cooled, Fuel: Diesel, No Of Cylinders : 2 In Linestarting System : 12 V Dc Electrical, Class Of Insulation: Hclassmax Unbalanced Load Across Phases: Less Than Or Equal To 25%Stator Winding: Double Layer Lapperformance Class: Up To Iso 8528-5 G2.Job Includes Providing And Fitting Of :1 ) 3.5 Core 25Mm Lt Cable 50 Mtrs And4cx2.5 Sqmm Cooper Cable For Amf Control Cable 50 Mtrs.2 ) Pcc Foundationfor Housing Of Dg Set In Ration 1:2:4 ( M20 Grade ) , Foundation To Be Additional 1 Ft Of The Dg Set Dimension On Each Side, Height Of Foundation 30 Cms Above Ground Level.3 ) 4 Nos Chemicalearthing.4 ) Electrical Connection To Existing System As Per Site Requirement.