}

Tender For Purchase Of Physiotherapy Equipments For Rajiv Gandhi Sports Medicine Center, Thiruvananthapuram, thiruvananthapuram-Kerala

Government Departments has published Tender For Purchase Of Physiotherapy Equipments For Rajiv Gandhi Sports Medicine Center, Thiruvananthapuram. Submission Date for this Tender is 25-11-2023. Physiotherapy Equipment Tenders in thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40554200
Tender For Purchase Of Physiotherapy Equipments For Rajiv Gandhi Sports Medicine Center, Thiruvananthapuram
Open Tender
Indian
Kerala
Thiruvananthapuram
25-11-2023

Tender Details

Purchase Of Physiotherapy Equipments For Rajiv Gandhi Sports Medicine Center, Thiruvananthapuram , Physiotheraphy Equipments , Od189943 / 2023_2024 : Super Inductive System Therapy Device;Intensity Of Electro Magnetic Field - Up To 2.5 Tesla ;Frequency - 1 To 150Hz;Highly-Effective, Non-Invasive Treatment For Pain, Joint Mobilization, Spasticity Reduction, Fracture Healing.;The Systems Should Have Multi-Language User Interface. The Unit Must Have Built-In Therapeutic Encyclopedia - Description And Images Explaining Application Of All Pre-Programmed Treatment Programs. Should Have Pre-Programmed Protocols. The Device Must Have Large Touch Color Screen Display - 8.4 Inches. The Device Must Do Self-Identifications Of Accessories And Accessories Maintenance Check. The Device Must Have Only One Single Universal Applicator. The Focused Field Applicator Must Have Intensity In Range Of 0.7 To 2.5 Tesla. Frequency Range Must Be From 1-150 Hz ( Not Less Than 150 Hz ) . Screen Pen Pointer Should Be Available Touch. The Device Must Have Single Applicator Arm With Cable Holder. For Holding The Applicator, It Should Have 6 Joint Arm Installation Set. The Device Must Provide Hands Free, Therapist Independent Application Though The Holder. Mains Supply Voltage 100-230V / Frequency 50-60Hz. Class According To Mdd 93 / 42 / Eec - Ii A. The Device Must Be Us Fda Approved &European Ce Approved. , Od189944 / 2023_2024 : Combination Therapy Unit- Electrotherapy And Ultrasound With Hands Free Ultrasound Applicator Combination Therapy Unit Having Facility Of Electrotherapy And Ultrasound. Should Have Medical Encyclopedia Into The System With Anatomical Library, And Informative Screens. Should Have Facility For Pre- Programmed Protocol Selection Through List Navigation / Quick Protocols / Body Part Navigation. Should Have Large Colour Touch Screen Display Should Have Large Number Of Pre-Programmed Indications For Electrotherapy ( More Than 70 ) , Ultrasound ( More Than 50 ) - Total More Than 100 Pre-Set Programs. Should Have The Facility Of Up-Grading The Firmware In Future. Should Be Able To Treat 2 Patients At The Same Time With Independent Therapies Therapies Or Same Patient With 2 Different Indications. Should Have Possibility To Operate Ultrasound Simultaneously / Independently While Giving 4 Pole Electrotherapy Treatment Or Two 2- Pole Treatments And 1 Ultrasound Therapy Simultaneously. Should Have Ce / Iso Certification. Should Have Fda Certification. Should Have Option For Operation Through Battery. Electrotherapy Unit Should Have 2 Channel Electrotherapy With Both Independent Channels. Should Have The Following Currents: Galvanic, Faradic, Neofaradic, Diadynamic Currents, Tens Currents ( Sym, Asym, Alt ) , Interferential Currents ( 2 Pole, 4-Pole, Iso-Planar And Dipole Vector Field ) , Micro Currents, High Voltage Therapy, H-Wave, Leduc Current, Medium Frequency Surges, Exponential Pulses, Exponential Pulses With Rise, Combined Pulses, Interrupted Pulses, Rectangular Pulses, Traebert Pulses, Russian Stimulation, Stimulation Pulses, Rectangular Pulses, Triangular Pulses, Interrupted Pulses And Medium Frequency Surges, Spastic Stimulation - Hufschmidt, Spastic Stimulation -Jantsch, Hvt, Ig Pulses, Modulatedpulsed Current, Vms Current, Kotz Current, Epir. Should Have Electro-Diagnostics ( Measuring Of I / T Curves In User Defined Number Of Points, Free Programme Position For I / T Curve Storing, Determination Of Motor Point, Calculation Of Rheobasis And Chronaxie, Measuring Of The Accommodation Coefficient ) . Should Have Facility For Constant Voltage / Constant Currents Modes Should Have Facility Of Plotting And Storing Sd Curves For Comparison And Future Reference. Should Have: Mains Supply: 230V / 50-60Hz, 115V / 50-60Hz ;Class According To Mdd 93 / 42 / Eec : Iib. Ultrasound Therapy With Hands Free Ultrasound Applicator Should Have Ergonomic Heads With Facility For Visual Accessory Identification / Visual Patient Contact Indicator On Screen As Well As On Treatment Head. Should Have Head Warming Facility For Treatment Head. ;Should Have Facility To Connect 2 Us Heads At The Same Time And Same Should Be Available For Selection While Setting Up Parameters For Treatment Through Software Saving Operator&Rsquo;S Time And Effort. Should Have Large Hands Free Ultrasound Applicator-4 Crysta ( 12 Cm2 ) With Rotary Field Technology And Simultaneous Treatment With 1&3Mhz For Future Upgrade. Should Have Ergonomic Multi Frequency Treatment Head For 1& 3 Mhz Treatment ( Standard-Era 5Cm2 And Optional- 1 Cm2 ) ;Should Have Alternating Frequencies 1 And 3 Mhz Allowing Simultaneous Treatment With 1 And 3 Mhz. ;Should Have Duty Factor Of 5-95%, In Steps Of 1%. Should Have Modular Frequency: 10-150Hz. Should Have Peak Intensity Of 0-2 W / Cm&Sup2; - Duty Cycle 100% In Continuous Mode And 0-3 W / Cm&Sup2; - Duty Cycle &Lt; 100% In Pulsed Mode. Should Have Beam Non-Uniformity Ratio<5. Should Have Head Warming Facility. Should Have Treatment Time Of 0-30 Minutes. , Od189945 / 2023_2024 : Combination Therapy Unit - Electrotherapy And Ultrasound Combination Therapy Unit Having Facility Of Electrotherapy And Ultrasound Should Have Medical Encyclopedia Into The System With Anatomical Library, And Informative Screens. Should Have Facility For Pre- Programmed Protocol Selection Through List Navigation / Quick Protocols / Body Part Navigation. Should Have Large Colour Touch Screen Display. Should Have Large Number Of Pre-Programmed Indications For Electrotherapy ( More Than 70 ) , Ultrasound ( More Than 50 ) - Total More Than 100 Pre-Set Programs. Should Have The Facility Of Up-Grading The Firmware In Future. Should Be Able To Treat 2 Patients At The Same Time With Independent Therapies Therapies Or Same Patient With 2 Different Indications. Should Have Possibility To Operate Ultrasound Simultaneously / Independently While Giving 4 Pole Electrotherapy Treatment Or Two 2- Pole Treatments And 1 Ultrasound Therapy Simultaneously. Should Have Ce / Iso Certification. Should Have Fda Certification. Should Have Option For Operation Through Battery. Electrotherapy Unit Should Have 2 Channel Electrotherapy With Both Independent Channels Should Have The Following Currents: Galvanic, Faradic, Neofaradic, Diadynamic Currents, Tens Currents ( Sym, Asym, Alt ) , Interferential Currents ( 2 Pole, 4-Pole, Iso-Planar And Dipole Vector Field ) , Micro Currents, High Voltage Therapy, H-Wave, Leduc Current, Medium Frequency Surges, Exponential Pulses, Exponential Pulses With Rise, Combined Pulses, Interrupted Pulses, Rectangular Pulses, Traebert Pulses, Russian Stimulation, Stimulation Pulses, Rectangular Pulses, Triangular Pulses, Interrupted Pulses And Medium Frequency Surges, Spastic Stimulation - Hufschmidt, Spastic Stimulation &Ndash; Jantsch, Hvt, Ig Pulses, Modulated Pulsed Current, Vms Current, Kotz Current, Epir. Should Have Electro-Diagnostics ( Measuring Of I / T Curves In User Defined Number Of Points, Free Programme Position For I / T Curve Storing, Determination Of Motor Point, Calculation Of Rheobasis And Chronaxie, Measuring Of The Accommodation Coefficient ) . Should Have Facility For Constant Voltage / Constant Currents Modes. Should Have Facility Of Plotting And Storing Sd Curves For Comparison And Future Reference. Should Have Mains Supply :230V / 50-60Hz, 115V / 50-60Hz ; Class According To Mdd 93 / 42 / Eec : Iib. Ultrasound Therapy Should Have Ergonomic Heads With Facility For Visual Accessory Identification / Visual Patient Contact Indicator On Screen As Well As On Treatment Head. Should Have Head Warming Facility For Treatment Head. Should Have Facility To Connect 2 Us Heads At The Same Time And Same Should Be Available For Selection While Setting Up Parameters For Treatment Through Software Saving Operator&Rsquo;S Time And Effort. Should Have Large Ultrasound Applicator And Simultaneous Treatment With 1&3Mhz For Future Upgrade. ;Should Have Ergonomic Multi Frequency Treatment Head For 1& 3 Mhz Treatment ( Standard-Era 5Cm2 And Optional- 1 Cm2 ) . Should Have Alternating Frequencies 1 And 3 Mhz Allowing Simultaneous Treatment With 1 And 3 Mhz. Should Have Duty Factor Of 5-95%, In Steps Of 1%. Should Have Modular Frequency: 10-150Hz. Should Have Peak Intensity Of 0-2 W / Cm&Sup2; - Duty Cycle 100% In Continuous Mode And 0-3 W / Cm&Sup2; - Duty Cycle &Lt; 100% In Pulsed Mode. Should Have Beam Non-Uniformity Ratio&Lt;5 Should Havehead Warming Facility. Should Have Treatment Time Of 0-30 Minutes. , Od192189 / 2023_2024 : Trolley For Combination Therapy Unit With At Least 5 Drawers For Storage Of Accessories .

Key Value

Document Fees
INR 2950 /-
EMD
INR 50000.0 /-
Tender Value
INR 43.76 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail