Repairs To Cooling Appliances Refrigerator And Other Associated Items And Other Connected Works At Saa Under Ge ( S ) Tezpur- 1 Air Conditioner :- M&L For Taking Out U / S Air Conditioner Window / Split Type In Cappacity 1.5 And 2 Tonfor Replacing To U / S Spares / Re-Painting / Servicing / Carrying Out Neccessary Repairing Works / Shifting Location / Gas Re-Filling Etcin Any Type / Cap / Make / Modelall As Site With Connecting Accessories From Existed Location After Removing All Connections Safely And Transportation From Site To Work Shop And Back ( If Required ) At Same After Repairing Work Complete All As Directed.Note :- Connecting Accessories Will Be Taken In Safy Custody By Contractor For Re-Using At Same. ( Ii ) All Spaires Shall Be Measured And Paid Against Respective Items . 2 M&Lfor Dusting, Cleaning By Compressed Air, Washing Using Casting Soda Mixed Waterafter Scraping To Old Paint Coatto Bepreparing The Surface For Re-Painting To Air Condioner In Any Type / Make / Model / Cap / Etc All As Site Using Heat Resistive / Synthetic Enamel Paintby Paint Spray Gunin Two Coats Over One Coat Of Red Oxide Primer And Indication Markingby Diffirent Colour In Standard Size Of Letter Complete All As Directed .Note :- ( I ) Paint Colourshall Be Approved By Engr-In-Charge. ( Ii ) All Spares Required To Servicing Shall Be Measured And Paid Sepretly. 3 Supply And Re- Filling / Charging Of Refrigerant Gas Of R-134A, R-32, R-410A, R-22In Origional Towindow Or Split Type Air Conditioner Upto 2 Ton Capacity, Water Cooler / Refiregator And De- Freezerupto Speicific Pressure / Grade Complete All As Directed. Note : Grade Of Refrigerant Shall Be Supplied As Permodel / Make Requirement In Origional. 4 Labourfor Re- Fixing / Installation / Connecting / Testing And Commissioning Of Repairedair Conditioner Under Above Itemin Origional Postion All As Same As Per Exsited Incl Making Electric / Air Connections Withother Site Requiredwork For Serviceablitycomplete All As Directed . 5 M&L For Making Hole For Fixing Of Window Air Condioner For Any Type / Make / Model / Capacity Etc. After CuttingwindowS Net Made Out By Ms Bar Or Strip / Brick Wall Etcincl All Type All Required Insulating / Fixing Materials Such As Thermocoal / Peice Of Plywood Etc Complete All As Siteand Directed. Note :- Quoted Rate Shall Be Included Making Good To Disturbed Surface As Exisiting. 6 Supply And Fixing In Replacement Ofrotary Dc Compressorunit For Invertor Window Type Cap 1.5 Tr.230 V, Single Phase.As Required In Origional Manufactures Complete All As Directed.Note :- ( I ) All Spares Shall Be Hold Original Manufacture Tag With Cat No. ( Ii ) Spare Will Be Supplied In OriginalmakeAs Given Sample 7 All As Above Item No 6 Butrotary Dccompressor Unit For Invertorsplit Type Cap2 Tr.230 V, Single Phase Complete. 8 All As Above Item No 6 But Reciprocating / Rotaryac Compressor Unit For Window Type Cap Upto 1.5Tr.230 V, Single Phase Complete. 9 All As Above Item No 6 But Reciprocating / Rotary Accompressor Unit For Split Type Cap Upto 2 Ton.230 V, Single Phase Complete. 10 All As Above Item No 6 But Starting / Running Capatior For Existing Model Of Split / Window Ac. 11 All As Above Item No 6But Condenser Unit For Window Type 12 All As Above Item No 6 Butindoor Unit Blowerfan Motor For Split Type Cap 1.5 Tr. 13 All As Above Item No 6 Butout Door Unit Fan Motor For Split Type Cap 1.5 Tr. 14 All As Above Item No 6 Butindoor Unit Fan Blowermotor For Split Type Cap 2 Tr. 15 All As Above Item No 6 Butout Door Unit Fan Motor For Split Type Cap 2 Tr 16 All As Above Item No 6 But Blowerfan Motor For Window Ac Cap 1.5 / 2 Tr 17 All As Above Item No 6But Pcb Outdoorfor Split Type Ac Cap 1.5 / 2 Ton. As Per Site Requirement. 18 All As Above Item No 6But Pcb Indoorfor Split Type Ac Cap 1.5 / 2 Tonwith Remote Control. 19 All As Above Item No 6But Pcbfor Windowtype Ac Cap 1.5 / 2 Ton. 20 All As Above Item No.6 But Dcstapping Motor. 21 All As Above Item No.6 But Thermostate Assembly. 22 All As Above Item No.6 But Indoor Condensestion Unit For Split Type 1.5 Trac . 23 All As Above Item No.6 But Outdoor Condensestion Unit For Split Type 1.5 Tr Ac. 24 All As Above Item No.6 But Indoor Condensestion Unit For Split Type 2 Tr Ac. 25 All As Above Item No.6 But Outdoor Condensestion Unit For Split Type 2 Tr Ac. 26 All As Above Item No.6 But Relay For Ac For Window / Split Type Cap 1.5 / 2 Tr. 27 All As Above Item No.6But Front Panel Grill. 28 All As Above Item No.6But Remot Control Suitable For As Site Unit. 29 All As Above Item No. 6But Automatic Sensor Card. 30 All As Above Item No. 6Capacitor For Fan Motor. 31 All As Above Item No. 6Air Filter For Split / Window Type Ac. 32 All As Above Item No. 6Swing Motor For Indoor Unit Of Split / Window Ac. 33 Flyshing And Leak Testing Of Complete System With Nitrogen Gas And Topping Up Compressor Oil. 34 S&F In Replacement For Blades Ofmodel Of Existing / Suitable Model Of Window / Splite Type ( Outdoor Unit ) Of Capacity Up To 2 Tr 35 M&L For Servicing, Oiling, Greasing, Cleaning, Dusting , Overhauling Etc All As Site Requirement Works For Air Conditioner In All Make / Type / Model / Cap Upto 2 Ton Etcfor Making Serviceable With Satisfactions Including Disconneting, Removing, Re-Fixing , And Re-Connecting All As Siteand Directed. 36 M&L For Replacing To Rusted Body Portion / Partof Air Conditioner In All Make / Model / Capacity Etc As Siteusing Ms Sheets Minium 18 Gauge For Body And Angle For Frame Work Including Jointing Welding Cutting Etc All Works Finishing / Painting To Matching With Existing Surface Complete All As Directed. 37 Water Cooler / Refiregator And De- Freezer :- Labourfor Taking Out U / S Water Cooler / Refrigerator And Deep- Freezerof Any Make / Model / Capacity Etc For Replacing To U / S Spares / Re-Painting / Servicing / Carrying Out Neccessary Repairing Works / Shifting Location / Gas Re-Filling Etcin Any Type / Cap / Make / Modelall As Site With Connecting Accessories From Existed Location After Removing All Connections Safely And Transportation From Site To Work Shop And Back ( If Required ) At Same After Repairing Work Complete All As Directed. Note :- ( I ) Connecting Accessories Will Be Taken In Safy Custody By Contractor For Re-Using At Same. ( Ii ) All Spaires Shall Be Measured And Paid Against Respective Items . 38 M&L For Servicing, Oiling, Greasing, Cleaning, Dusting Overhauling To Water Cooler / Refrigerator And Deep- Freezerin Any Make / Model / Capacity Etc All As Site Requirement Works Forin All Make / Type / Model / Cap Etcfor Making Serviceable With Satisfactions Including Disconneting, Removing, Re-Fixing , And Re-Connecting All As Same At Siteand Directed. 39 M&L For Replacing To Rusted Body Portion / Partof Refrigerator / Water Cooler / Deep- Freezeretcin All Make / Model / Capacity Etc As Siteusing Ms Sheets Minium 18 Gauge For Body And Angle For Frame Work And Base Unit Including Jointing Welding Cutting Etc All Works Finishing / Painting To Matching With Existing Surface Complete All As Directed. 40 Supply And Fixing In Replacement Ofcompressore Unit For 40 To 80 Ltr Storage Capacity Suitablefor Refrigerator / Water Cooler / Deep- Freezer In Any Capacity / Make / Model / Type Etcas Site In Origional Manufactures Complete All As Directed. Note :- ( I ) All Spares Shall Be Hold Original Manufacture Tag With Cat No. ( Ii ) Spare Will Be Suitable For All Capacity And Makelg / Voltas / Blue Star / Usha / Vidiocon / Usha / Sumsang / Annapurna / Whirlpool / Gojrej / Danfoss / Tecumseh Etc As Site. 41 All As Above Item No 40 But Compressor Unit For 150Ltr Storage Capacity. Make - Kirloskar / Tecumseh / Godrej 42 All As Above Item No 40 But Compressor Unit For 165 / 205 Ltrs Capacity Make - As Per Sample With Origional Tag 43 All As Above Item No 40 But Compressor Unit For 286 / 300Ltr Capacity. Make - As Per Sample With Origional Tag 44 All As Above Item No 40 But Evaporator Assembly Single / Double Door Refrigerator Capacity Upto 205 Ltr. Make - As Per Sample With Origional Tag 45 All As Above Item No 40 But Evaporator Assembly Single / Double Door Refrigerator Capacity 280 To 300 Ltr .Make - As Per Sample With Origional Tag 46 All As Above Item No 40But Evaporator Assembly Water Cooler / Deep- Freezer Capacity Upto 205 Ltrs 47 All As Above Item No 40 But Evaporator Assembly Water Cooler / Deep- Freezer Capacity280 To 300 Ltrs 48 All As Above Item No 40But Duct Assembly Double Door. 49 All As Above Item No 40 But Driyer For Refrigerator. 50 All As Above Item No 40But Motor Dc Single / Double Door 51 All As Above Item No 40But Power Cord Single / Double Door 52 All As Above Item No 40But Controller Assembly Single / Double Door 53 All As Above Item No 40But Over Load Unit. 54 All As Above Item No 40Butmain Pcb Forsingle / Double Doorrefrigerator Of Any Capacity. 55 All As Above Item No 40Butthermostate Big / Small 56 All As Above Item No 40But Condensation Unit 57 All As Above Item No 40 Butbulb & Holder But Make And Model Etc 58 All As Above Item No 40 But Door Lock And Key In Origional But Make And Model Etc 59 All As Above Item No 40 But Gasket Or Door Bedding Rubber For Complete Inner / Outer Unit. 60 All As Above Item No 40 But Relay 61 All As Above Item No 40 Butcapacitor / Condensor 62 All As Above Item No 40 But Blower Motor 63 All As Above Item No 40 But Chiller / Ice Tray 64 All As Above Item No 40 Butvegitable Tray 65 All As Above Item No 40 But Copper Capillary Cooling Coil Tubeassembly 66 All As Above Item No 40 Butreplacing To Door Hinges As Origional 67 All As Above Item No 40 Butdoor / Stand Rubber Cushion Pad Set 68 All As Above Item No 40 But Temprature Controll Panel 69 All As Above Item No 40 But Pvc Mounting Stand For Refiregetor 70 All As Above Item No 40 But Timer Assembly 71 M&L For Servicing / Cleaning, Dusting, Overhauling , Oiling Etc All To Make In Serviceable Torefrigerator / Water Cooler Or Deep- Freezer In Any Make / Model / Capacity / Rating Etc All As Site Completeas Directed. 72 Water Heater Or Geyser :- M&L For Taking Down Water Heater / Geyser In Any Make / Model / Type / Size Etc As Site And Open To Body / Connecting Partsfor Repair / Replaing To U / S Spares , Servicing , Cleaing, Overhauling, Paintingetc All As Site After Removing Connections Complete All As Specified. Note : ( I ) Spares Shall Be Measured And Paid Seprately. ( Ii ) Quoted Rate Shall Be Included Transpotion Charge In Required ( If Required ) 73 M&L For Painting Towater Heater / Geyser In Any Make / Model / Size / Capacity Using Two Coats Over One Coat Of Red Oxide Primer Usingsyenthetic Enamel / Heat Resitance Paint After Washing With Casting Soda Water , Scarping To Old Paint, Cleaning Etc And Identy Marking By Different Colour As Per Exisiting Completeall As Specified And Directed. Note :- Colour Of Paint Shall Be Approved By Engr-In- Charge. 74 Supply Only Base Assmebly For 25 Ltrs Capacityinlet And Outlet Of Geysermadeout Of Copper Base Plate With Gasket, Nuts, Boltsand Washer Etc Suitablefor Water Heater / Geyser In Any Type / Capacity / Model / Make / Size Etcas Required In Origional Manufactures Complete All As Directed. Note :- ( I ) All Spares Shall Be Hold Original Manufacture Tag With Cat No. ( Ii ) Spare Will Be Suitable For Makevoltas / Blue Star / Havells / Bajaj / Usha Etc Allas Site. 75 All As Above Item No 74 But Base Assmebly For 50 Ltrs Capacityinlet And Outlet Of Geysermadeout Of Copper Base Plate With Gasket, Nuts, Boltsand Washer Etc.Make - As Per Sample With Origional Tag 76 All As Above Item No 74 But Water Heating Element For 1.5 / 2Kw Cap Trinangular And Round Type .As Per Sample And Make. 77 All As Above Item No 74 Butthermostate Asssembly Manually Adjustment Type Setting Range With 35 To 65 Cc. Adjustable. 78 All As Above Item No.74Butauto Temperature Cut Out Unit 79 All As Above Item No 74 Butindicator Lamp 220 Volts Ac 80 All As Above Item No 74 Butsafety Pressure Release Valve. 81 All As Above Item No.74 But Pvc Float Valve With Epoxy Coated Aluminium Arm , With Pvc Polythene Ball Suitable For Water Coolers. 82 All As Above Item No.74 Butinter Connection Pipe With Metal Sockets At Both End Inand For 90 Cc Hot Water Isi Mark. 83 All As Above Item No. 74 Butpvcinter Connection Pipe With Metal Sockets At Both End In 600 Mm Length. 84 Supply Onlyfan Hook / Clamps Made Out By Gi Strip 20 Mm Width 4 Mm Thick Incl Cutting, Bending, Fitting, Painting , Nut Bolts Washers Etc All As Site Suitable For Fitting To Ceiling Fan Complete All As Directed. 85 Supply Onlypvc Insulated Sheathed Multistandred Copper Conductorcable 3 Core 4 Sqmm 1100 Volts Grade. 86 Supply Only Pvc Insulated Sheathed Multistandred Copper Conductorcable 3 Core 2.5 Sqmm 1100 Volts Grade. 87 Supply Onlypvc Insulated Sheathed Multistandred Copper Conductorcable Single Core 4 Sqmm 1100 Volts Grade. 88 Supply And Fixing / Laid / Clamping Of Wall Etc As Site Galvasined Steel Tubing With All Fittings In Medium Grade Bore Of Dai 15 Mm All As Specified And Directed. 89 Supply And Fixing / Laid / Clamping Of Wall Etc As Site Galvasined Steel Tubing With All Fittings In Medium Grade Bore Of Dai 20 Mm All As Specified And Directed. 90 Supply And Fixing In Repair Of New Water Heater ( Gyser ) Storage Type, Single Phase, Energy Saving 5 Star Rated 230 Volts Grade 5 Star Rated25 Ltrs Storage Capacity Complete With Chomium Inter Connecting Pipe , Nutt, Bolts , Washers And Other Site Required Accessories. Note : Quoted Rate Shall Be Included Nutt Bolt And Washer, Inter Connection Pipe Set With All Other Required Accessories. Make :-Havells, Bajaj, Cg, Usha 91 All As Above Item No 90 But Here-In-Before But Capacity 10 Ltrs. Make - Havells, Bajaj, Cg, Usha 92 Shifting And Installation Of Split / Window Type Ac Any Make / Capacity At One Place To Another All As Spacified And Directed 93 Supply And Fixing / Laid / Concealed Clamping Of Wall Etc As Site Copper Pipe For Suction / Discharge Linewith All Fittings Inbore Of 1 / 2, 1 / 4, 5 / 8, 3 / 4All As Specified And Directed. 94 Supply And Fixing In Repair Ofout Door Unit Of Air Cooled Split Unit Air Conditioners Electric Driven Single Phase Of Capacity Of 1.5Tr With Minimum 5 Star Ratingeer 3.2 , Including Iron Clamp For Mounting Of Outdoor Unit Complete All As Specified And Directed. 95 Supply And Fixing In Repair Ofindoor Wall Mounting Unit Of Air Cooled Split Unit Air Conditioners Electric Driven Single Phase Of Capacity Of 1.5Tr With Minimum 5 Star Ratingeer 3.2 Complete All As Specified And Directed. 96 Supply And Fixing And Connecting Inreplacement Of Fully Automatic Single Phase Naturally Air Cooled Indoor Type Wall Mounting Type Digital Voltage Stabilizervoltage Variation Between 130 To300 Voltswith Output Voltage Stabilizer At 230 V With Accuracyof + / - 2.5% Of Capacity 5 Kva ( Suitable Up To 2 Ton Or 24000 Btu / Hr ) W Tdr All As Specified And Directed Make : V-Guard Model Vd 500 In Equivelent Microtek / Ae / Volina 97 All As Above Item No 96But Of Capacity 4 Kva ( Suitable Up To 1.5 Ton Or 24000 Btu / Hr ) W Tdr All As Specified And Directed Make : V-Guard Model Vd 500 In Equivelent Microtek / Ae / Volina Note 1:-The Contract Sum Shall Be Arrived At After Deducting Amount Of Schedule Of Credit From The Total Quoted Amount. Note 2-ContractorS Supervisor And Main Worker Would Wear Shirt / T-Shirt Of Colour Sky Blue / Brown / Yellow Preferable Embossed With ContractorS Firm Name While Carrying Out Any Activities In Defence Area For Better Check Of Security Purpose.Note 3:-The Tenderer ( All Eligible Contractors ) Shall Ascertain The Taxes & Levies As On Date. The Subject Tender Caters All The Taxes & Levies As On Date Including The Latest Notification Of Gst Issued As On Date ( Issued By Central Board Of Indirect Taxes And Customs )