Annual Plan- [ Pro:No:287 / 22-23 ] Maintenance Of Valupacha Sisumandiram - Ward No:7 Of Kadakkal Grama Panchayath Of Chadayamangalam Block-Maintenance Of Sisumandiram -General Civil Work.; 1 Maintenance Of Sisumandiram 2 15.17.1:Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metes Lead In:R.S. Joists 3 50.12.4.1:Providing And Fixing False Ceiling With 7.5 Mm Thick Pvc Plain Panel Board Ceiling Of Approved Quality In Aluminium Frame Work With Necessary Screws Etc Complete ( Aluminium Frame Work Shall Be Paid Separately ) 4 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 5 10.29.1:Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete.Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1.4 Mm Aperture On Both Sides 6 13.62.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Givean Even Shade:Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture . 7 14.66.1:Finish Walls With Acryllic Smooth Exterior Paint Of Required Shade:Old Work ( Two Or More Coats Applied @ 1.67 Ltr / 10 Sqm ) On Existing Cement Paint Surface 8 21.5:Providing And Fixing Powder Coated Aluminium Work ( Minimum Thickness Of Powder Coating 50 Micron ) Consisting Of Tee / Angle Sections, Of Approved Make Conforming To Is : 733 In Frames Of False Ceiling Including Aluminium Angle Cleats With Necessary C.P Brass / Stainless Steel Sunk Screws, Aluminium Perimeter Angles Fixed To Wall With Stainless Steel Rawl Plugs @ 450 Mm Centre To Centre And Fixing The Frame Work To G.I Level Adjusting Hangers 6 Mm Dia. With Necessary Cadmium Plated Machine Screws All Complete As Per Approved Architectural Drawings And Direction Of The Engineer-In-Charge ( Level Adjusting Hangers, Ceiling Cleats And Expansion Hold Fasteners To Be Paid For Separately ) . 9 50.9.1.1:Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood 10 50.9.3.1:Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili / Jack Wood 11 50.9.6.1:Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 12 11.39:Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is: 15622, Of Approved Make In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 13 16.91.1:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocksin Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid Inrequired Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting Andproper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layerthrough Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand Andcutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweepingextra Sand. Complete All As Per Direction Of Engineer-In-Charge.60Mm Thick Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern. 14 14.6.1:Renewing Glass Panes, With Wooden Fillets Wherever Necessary: Float Glass Panes Of Nominal Thickness 4 Mm ( Weight Not Less Than 10Kg / Sqm ) 15 14.85:Taking Out Existing Wooden Door Shutter, Repair By Cutting, Painting Etc. And Refixing Of Repaired Door Shutters To Existing Door Frames, Including Replacement Of Hinges With Screws, Etc. As Required, All Complete As Per The Direction Of The Engineer-In-Charge. 16 50.14.1.1:Removing And Refixing Door Shutters After Necessary Repairs For Easy Opening And Closing Etc Complete As Per The Direction Of Site Engineer-In-Charge. 17 50.14.1.2:Removing And Refixing Window Shutters After Necessary Repairs For Easy Opening And Closing Etc Complete As Per The Direction Of Site Engineer-In-Charge 18 9.58.2:Providing And Fixing Isi Marked M.S. Pressed Parliamentary Hinges With Necessary Screws Etc. Complete125x125x27x2.80 Mm 19 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand ) 20 4.1.3:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 ( Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 20 Mm Nominal Size )