}

Tender For Fixing Of Rate Contract For Repairs To Electrical Equipment Installed At Different Wsss Of Jal Shakti (Phe) Mechanical Division (North) Sopore For A Period Of One Year., sopore-Jammu And Kashmir

Government Departments has published Tender For Fixing Of Rate Contract For Repairs To Electrical Equipment Installed At Different Wsss Of Jal Shakti (Phe) Mechanical Division (North) Sopore For A Period Of One Year.. Submission Date for this Tender is 28-10-2023. Electrical Maintenance Tenders in sopore Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40338206
Corrigendum : Tender For Fixing Of Rate Contract For Repairs To Electrical Equipment Installed At Different Wsss Of Jal Shakti (Phe) Mechanical Division (North) Sopore For A Period Of One Year.
Open Tender
Indian
Jammu And Kashmir
Sopore
28-10-2023

Tender Details

Fixing Of Rate Contract For Repairs To Electrical Equipment Installed At Different Wsss Of Jal Shakti ( Phe ) Mechanical Division ( North ) Sopore For A Period Of One Year.- Providing, fitting and testing of Copper thimbles at site 2 10 Sq. mm 3 16 Sq. mm 4 25 Sq. mm 5 50 Sq. mm 6 90 Sq. mm 7 120 Sq. mm 8 150 Sq. mm 9 185Sq. mm 10 240Sq. mm 11 300Sq. mm 12 Providing, fitting and testing of Aluminum thimbles at site 13 10 Sq. mm 14 16 Sq. mm 15 25 Sq. mm 16 50 Sq. mm 17 90 Sq. mm 18 120 Sq. mm 19 150 Sq. mm 20 185Sq. mm 21 240Sq. mm 22 300Sq. mm 23 Providing, fitting of below mentioned item for repairs to 25KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 24 Copper wire of specific gauge for fabrication of primary / secondary coil 25 Bush rod with porcelain insulator and packing 26 Re-taping /re-insulation of coils 27 T-Oil 28 Copper strip 29 Filtration / dehydration of T-oil 30 Cost of damaged lamination 31 Providing, fitting of below mentioned item for repairs to 30KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 32 Copper wire of specific gauge for fabrication of primary / secondary coil 33 Bush rod with porcelain insulator and packing 34 Re-taping /re-insulation of coils 35 T-Oil 36 Copper strip 37 Filtration / dehydration of T-oil 38 Cost of damaged lamination 39 Providing, fitting of below mentioned item for repairs to 35KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 40 Copper wire of specific gauge for fabrication of primary / secondary coil 41 Bush rod with porcelain insulator and packing 42 Re-taping /re-insulation of coils 43 T-Oil 44 Copper strip 45 Filtration / dehydration of T-oil 46 Cost of damaged lamination 47 Providing, fitting of below mentioned item for repairs to 40KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 48 Copper wire of specific gauge for fabrication of primary / secondary coil 49 Bush rod with porcelain insulator and packing 50 Re-taping /re-insulation of coils 51 T-Oil 52 Copper strip 53 Filtration / dehydration of T-oil 54 Cost of damaged lamination 55 Providing, fitting of below mentioned item for repairs to 50KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 56 Copper wire of specific gauge for fabrication of primary / secondary coil 57 Bush rod with porcelain insulator and packing 58 Re-taping /re-insulation of coils 59 T-Oil 60 Copper strip 61 Filtration / dehydration of T-oil 62 Cost of damaged lamination 63 Providing, fitting of below mentioned item for repairs to 75KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 64 Copper wire of specific gauge for fabrication of primary / secondary coil 65 Bush rod with porcelain insulator and packing 66 Re-taping /re-insulation of coils 67 T-Oil 68 Copper strip 69 Filtration / dehydration of T-oil 70 Cost of damaged lamination 71 Providing, fitting of below mentioned item for repairs to 100KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 72 Copper wire of specific gauge for fabrication of primary / secondary coil 73 Bush rod with porcelain insulator and packing 74 Re-taping /re-insulation of coils 75 T-Oil 76 Copper strip 77 Filtration / dehydration of T-oil 78 Cost of damaged lamination 79 Providing, fitting of below mentioned item for repairs to 150KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 80 Copper wire of specific gauge for fabrication of primary / secondary coil 81 Bush rod with porcelain insulator and packing 82 Re-taping /re-insulation of coils 83 T-Oil 84 Copper strip 85 Filtration / dehydration of T-oil 86 Cost of damaged lamination 87 Providing, fitting of below mentioned item for repairs to 250KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 88 Copper wire of specific gauge for fabrication of primary / secondary coil 89 Bush rod with porcelain insulator and packing 90 Re-taping /re-insulation of coils 91 T-Oil 92 Copper strip 93 Filtration / dehydration of T-oil 94 Cost of damaged lamination 95 Providing, fitting of below mentioned item for repairs to 400KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 96 Copper wire of specific gauge for fabrication of primary / secondary coil 97 Bush rod with porcelain insulator and packing 98 Re-taping /re-insulation of coils 99 T-Oil 100 Copper strip 101 Filtration / dehydration of T-oil 102 Cost of damaged lamination 103 Providing, fitting of below mentioned item for repairs to 450KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 104 Copper wire of specific gauge for fabrication of primary / secondary coil 105 Bush rod with porcelain insulator and packing 106 Re-taping /re-insulation of coils 107 T-Oil 108 Copper strip 109 Filtration / dehydration of T-oil 110 Cost of damaged lamination 111 Providing, fitting of below mentioned item for repairs to 600KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 112 Copper wire of specific gauge for fabrication of primary / secondary coil 113 Bush rod with porcelain insulator and packing 114 Re-taping /re-insulation of coils 115 T-Oil 116 Copper strip 117 Filtration / dehydration of T-oil 118 Cost of damaged lamination 119 Providing and fitting of single plate type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 120 150mmx150mm 121 225mm x 225mm 122 200mm x 200mm 123 250mm x 250mm 124 450 mm x 450 mm 125 300x300 MM 126 375mmx 375mm 127 600 mm x 600 mm 128 Providing and fitting of double plate type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 129 450 mm x 450 mm 130 600 mm x 600 mm 131 Providing and fitting of drum type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 132 32A 133 63A 134 100A 135 200A 136 Providing, fitting and testing of Voltmeters at site 137 0-200V 138 0-500V 139 Providing, fitting and testing of Ammeters at site 140 0-50A with CT ratio of 5/50 141 0-100A with CT ratio of 5/100 142 0-150A with CT ratio of 5/150 143 0-200A with CT ratio of 5/200 144 0-300A with CT ratio of 5/300 145 0-400A with CT ratio of 5/400 146 Providing, fitting and testing of post type drop out set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 147 Suitable for 25KVA Sub-station 148 Suitable for 63KVA Sub-station 149 Suitable for 100KVA Sub-station 150 Suitable for 250KVA Sub-station 151 Suitable for 630KVA Sub-station 152 Suitable for 33KV, 630KVA Sub-station (Heavy duty) 153 Providing, fitting and testing of link set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 154 Suitable for 25KVA Sub-station 155 Suitable for 63KVA Sub-station 156 Suitable for 100KVA Sub-station 157 Suitable for 250KVA Sub-station 158 Suitable for 630KVA Sub-station 159 Suitable for 33KV, 630KVA Sub-station (Heavy duty) 160 Providing, fitting and testing of polymer type pin insulator including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 161 Suitable for 11 KV HT line 162 Suitable for 33 KV HT line 163 Providing, fitting and testing of heavy duty 33 KV isolator (complete assembly) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 164 Replacement of damaged knives of isolator including greasing and alignment. The job includes extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 165 Replacement of damaged grip assembly of isolator including greasing and alignment. The job includes extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 166 Providing, fitting and testing of submersible copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 167 10 Sq mm 168 16 sq mm 169 25 sq mm 170 35 sq mm 171 Providing, fitting and testing of copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 172 19/0.0064 173 37/0.083 174 61/0.093 175 19/0.044 176 Providing, fitting and testing of 3.5 core XLPE aluminum conductor of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 177 35 Sq. mm 178 50 Sq. mm 179 70 sq.mm 180 95 Sq. mm 181 120 Sq. mm 182 150 Sq. mm 183 185 Sq. mm 184 240 sq.mm 185 300 sq.mm 186 Providing, fitting and testing of 11KV post type lightening arrestor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 187 Providing, fitting and testing of 33KV post type lightening arrestor (heavy duty) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 188 Providing, fitting and testing of G.O.D set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 189 Providing, fitting and testing of Cross arms including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 190 Channels 75x40 191 Angle iron support 192 F-top 193 U Clamps 194 Guy-wire with turn buckle 195 Guy-Insulator 196 Providing, fitting and testing of ACSR Conductor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 197 0.03 198 0.05 199 0.10 200 Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 201 63 Amps 202 100 Amps 203 125 Amps 204 160 Amps 205 200 Amps 206 250 Amps 207 320 Amps 208 400 Amps 209 630 Amps 210 Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 211 63 Amps 212 100 Amps 213 125 Amps 214 160 Amps 215 200 Amps 216 250 Amps 217 320 Amps 218 400 Amps 219 630 Amps 220 800 Amps 221 Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 222 63 Amps 223 100 Amps 224 125 Amps 225 160 Amps 226 200 Amps 227 250 Amps 228 320 Amps 229 400 Amps 230 630 Amps 231 Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 232 63 Amps 233 100 Amps 234 125 Amps 235 160 Amps 236 200 Amps 237 250 Amps 238 320 Amps 239 400 Amps 240 630 Amps 241 800 Amps 242 Providing, fitting and testing of on load 04 pole Change over switch of approved make as per damaged change over switch at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. 243 63 A 244 100 A 245 200 A 246 300 A 247 400 A 248 630 A 249 800 A 250 1000 A 251 Providing, fitting and testing of Combined volt-ammeter for MU-G starters 252 0-30A/0-500V 253 0-60A/0-500V 254 0-75A/0-500V 255 0-100A/0-500V 256 0-125A/0-500V 257 Providing, fitting and testing of 415V Indicating lamps 258 Red 259 Yellow 260 Green 261 Providing, fitting and testing of 415V Single phase preventor 262 Providing, fitting and testing of ML contactors for starters 263 ML 1.5 264 ML 2 265 ML 3 266 ML 4 267 ML 6 268 ML 10 269 ML 12 270 Providing, fitting and testing of Power contactors for FASD starters 271 LCIF 630 272 LCIF 400 273 LCIF 350 274 CK 95 BE-300 275 MNX 185 276 MNX 325 277 AC3-25A 278 AC3-32A 279 AC3-40A 280 AC3-50A 281 MC X 70 282 AC3- 60A 283 AC3- 63A 284 AC3- 80A 285 AC3- 100A 286 AC3- 115A 287 AC3- 125A 288 AC3- 150A 289 AC3- 185A 290 AC3- 200A 291 AC3- 250A 292 AC3- 265A 293 AC3- 330A 294 AC3- 350A 295 AC3- 400A 296 Providing, fitting and testing of ML relays 297 ML1 range 4-6.5 298 ML1 range 6-10 299 ML1 range 10-16 300 ML2/ML3 9-14 301 ML2/ML3 13-21 302 ML2/ML3 20-32 303 ML2/ML3 28-42 304 Providing, fitting and testing of FASD Panel accessories 305 Electronic timer 0- 30Sec 306 Electronic timer 0- 60Sec 307 Single Phase Preventer(Three phase type ) 308 Overload relay 4A-6A 309 Overload relay 5A-8A 310 Overload relay 6A-9A 311 Overload relay 7A-10A 312 Overload relay 9A-13A 313 Overload relay 12A-16A 314 Overload relay 14A-22A 315 Overload relay 17A-25A 316 Overload relay 23A-32A 317 Overload relay 30A-40A 318 Overload relay 37A-50A 319 Overload relay 48A-65A 320 Overload relay 55A-70A 321 Overload relay 63A-80A 322 Overload relay 80A-93A 323 Overload relay 85A- 105A 324 Overload relay 80A- 115A 325 Overload relay 125A- 200A 326 Overload relay 160A- 250A 327 Overload relay 200A- 315A 328 Overload relay 250A- 400A 329 Overload relay 315A- 500A 330 Overload relay 400A- 630A 331 Overload relay 500A- 800A 332 Overload relay 630A- 1000A 333 Replacement of damaged 1 Sq mm copper power wiring 334 Providing, fitting and testing of ATS star Delta starter 335 Pneumatic timer (on delay/off delay) 336 Electromagnetic power contactor assembly (10A-250A) 337 Providing, fitting and testing of Contact points of contactors for star/delta starters 338 20HP 339 30HP 340 40HP 341 50HP 342 Providing, fitting and testing of Terminal block 343 30A-5 way 344 60A-3 way 345 60A-6 way 346 100A-3 way 347 120A-3 way 348 Providing, fitting and testing of Power contactor for MU-G starters 349 MU-G10 350 MU-G15 351 MU-G20 352 MU-G30 353 MU-G40 354 MU-G50 355 MU-G75 356 Providing, fitting and testing of controller for MU-G starters 357 Providing, fitting and testing of Overload relay/under voltage relay for MU-G starters 358 MU-G10 359 MU-G15 360 MU-G20 361 MU-G30 362 MU-G40 363 MU-G50 364 MU-G75 365 Providing and fitting of Air Circuit breaker 630 amp Manual Draw out type 366 Providing and fitting of Air Circuit breaker 800 amp Manual Draw out type 367 Providing and fitting of GSM based remote access motor control module complete replacement. Model MPU-LCD 368 Providing and fitting of Multi-Function Meter Square Dial type. Model 383, Select Make. 369 Providing, fitting and testing of Motor protection circuit breakers with thermal adjustable ranges from 0-100 amp 370 0-32 Amp (16 steps) 371 28-63 Amp (03 steps) 372 55-100 Amp (03 steps) 373 Providing and fitting of Water level control relay with capsule modules and wiring 1 Sq mm copper minimum 90 Meters 374 Nuts and bolts of different size 375 Selector Switch 376 Providing, fitting of below mentioned item for repairs to 10KVA to 50KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 377 Replacement of digital micro controlled processor based control card 378 Replacement of AC syncronous servo motor 379 Replacement of copper wound motorized auto transformer 380 Replacement of buck and boost series transformer 381 Providing, fitting of below mentioned item for repairs to 50KVA to 100KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. 382 Replacement of digital micro controlled processor based control card 383 Replacement of AC syncronous servo motor 384 Replacement of copper wound motorized auto transformer 385 Replacement of buck and boost series transformer 386 Providing and fitting of LED Lamps with angle/straight holders with backlite plate at site 387 09 Watt 388 15 Watt 389 Erection of MS tubular 9m/11m tilted pole by way of excavation of new trench and concrete bottoming including fitting/fixing of Departmental ACSR conductor on the insulators 390 Repairs to VT Motor with rating from 10HP to 50HPDismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 391 Copper wire used in rewinding the motor. 392 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 393 Repairs to VT Motor with rating above 50HP to 150HP)Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 394 Copper wire used in rewinding the motor. 395 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 396 Repairs to VT Motor with rating above 150HP to 270HP)Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 397 Copper wire used in rewinding the motor. 398 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 399 Repairs to horizontal Motor with rating from 5HP to 50HPDismantling of the horizontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 400 Copper wire used in rewinding the motor. 401 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 402 Repairs to horizontal Motor with rating above 50HP to 100HPDismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 403 Copper wire used in rewinding the motor. 404 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 405 Repairs to horizontal Motor with rating above 100HP to 200HPDismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 406 Copper wire used in rewinding the motor. 407 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 408 Repairs to submersible Motor with rating from 2HP to 50HPDismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 409 Copper wire used in rewinding the motor. 410 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 411 Repairs to submersible Motor with rating from and above 50HP to 75HPDismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 412 Copper wire used in rewinding the motor. 413 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 414 Repairs to submersible Motor with rating from and above 75HP to 100HPDismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 415 Copper wire used in rewinding the motor. 416 Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc. 417 Replacing of damages illumination single core multistranded copper wiring 418 1 Sq mm 419 1.5 Sq mm 420 2 Sq mm 421 2.5 Sq mm 422 4 Sq mm 423 6 Sq mm 424 Providing and fitting of bimetallic tube terminals Al-Cu for cable thicknesses 425 10 Sqmm 426 16 Sqmm 427 18 Sqmm 428 25 Sqmm 429 35 Sqmm 430 50 Sqmm 431 90 Sqmm 432 120 Sqmm 433 150 Sqmm 434 Providing, fitting and testing of AC power monitor Proton make after extraction of damaged one 435 Providing, fitting and testing of VAF Meter, Model 39A, after extraction of damaged one 436 Providing, fitting and testing of motor protection unit MPU-12, Proton make, after extraction of damaged one 437 Fabrication, providing, fitting and testing of GM bushes to the submersible motors (finished) 438 Providing and fitting of aluminium bus bar of various sizes 439 Providing and fitting of copper bus bar of various sizes 440 Providing and fiting of PVC fans for horizontal motors 441 7.50HP to 10HP 442 12.50HP to 25HP 443 30HP to 60HP 444 60HP onwards 445 Providing, fitting and testing of contactor coils after dismantling of old damamged one 446 25A 447 32A 448 40A 449 50A 450 60A 451 63A 452 70A 453 80A 454 90A 455 100A 456 110A 457 115A 458 125A 459 150A 460 160A 461 185A 462 200A 463 250A 464 265A 465 315A 466 330A 467 350A 468 LC1F 350A 469 400A 470 LC1F 400A 471 500A 472 LC1F 500A 473 630A 474 LC1F 630A 475 Providing, fitting and testing of tripping coil to handle type starter 476 Upto 30HP 477 From 40HP to 150HP 478 150HP onwards 479 Providing, fitting and testing of Controller for MU-G starters(single phase preventer/Timer with manual, automatic, byepass function) 480 MU-G10 481 MU-G15 482 MU-G20 483 MU-G30 484 MU-G40 485 MU-G50 486 MU-G75 487 Repairs to ATS Starter CoilDismantling of the ATS Starter at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. 488 Copper wire used in rewinding 489 Associated/consumable items like crimpled paper, sleeves, PVC paper, thread, varnish etc. 490 Providing, fitting and testing of 6A Switch with box

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-10-2023 Corrigendum Financial Bid 28-10-2023

Key Value

Document Fees
INR 2000 /-
EMD
INR 80000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail