Tender For Lighting Arrangement For Main Building Campus Bhopal- 1 Providing And Erection Of Hot Dipped Galvanized Octagonal Poles In Single Section Made From 3Mm Thick Sheet Having Lockable Weather Proof Flush Door Junction Box, Suitable Size & Type Of Foundation Bolts 4 Nos. J Type ( En8 Grade ) Complete, Erected In An Approved Manner On Provided Foundation. 2 3 Meter Height 130 X 70Mm A / F, 200X200x12mm Base Plate, 4 Nos X 16 X 450Mm Bolt 3 Providing And Fixing Of Bakelite Sheet 10Mm Thick, One Mcb 6Amp-32Amp Sp & 16Sq.Mm Stud Type 4 Way Epoxy Connector For Decorative Designer Poles / Octagonal Pole Box. 4 Providing And Fixing Of Sword Canopy Type Single Arm Gi Bracket Upto 2 Meter Long For 70Mm A / F Top Octagonal Pole 5 Providing And Fixing Of Sword Canopy Type Double Arm Gi Bracket Upto 2 Meter Long For 70Mm A / F Top Octagonal Pole 6 Designing And Construction Of Footing Foundation For Octagonal Pole Of Desired Size Including Excavation In Soil / Soft Rock, Base Concrete M-7.5 ( 1:4:8 ) , 15Mm Thick And Pedestal Of Rcc M-20 ( 1:1.5:3 ) , Required Tar Steel Reinforcement For Required Size From Base Concrete, Shuttering, Curing Etc. With Existing Foundation Bolts Complete As Per Specifications In An Approved Manner As Per Manufacturer Drawing Or Engineer-In-Charge 7 Supply And Fixing Integral Post Top Lantern Led Fitting Comprises Of Copper Dust Finish Cast Aluminium Spigot And Spun Aluminium Canopy Fixed With Opal Polycarbonate, Pipe Arrangement For Vertical Mounting, Open Construction Driver And Accessories Are Wired Upto Terminal Block. Led Of 1 To 3 Watt Each Assembled On Single Mcpcb, Having Color Temp Upto 6500K & Having 50000 Burning Hrs. Life With Minimum @ L 70, System Lumen Output Should Be Minimum With Efficacy>100Lm / Watt. Led Driver Pf > 0.95 & Surge Protection 10Kv. The Colour Rendering Index Of Led Light Should Be More Than 70. Submission Lm 79-08 / Is16106 ( 2012 ) , Iec60598, Iec61347i / C Connection Wire, Testing Etc. To Complete The Job. 8 40 Watt Led, Color Temp 3000-6500K As Required. 9 Supply And Fixing Street Light With High Power Led Of 3 To 6 Watt Each On Existing Bracket Assembled On Single Mcpcb And Additional Unique Peanut Lens On Each Led, System Lumens Output With Efficacy>120 Lm / Watt. Luminiare Having Color Temp Upto 6500K & 50000 Hrs. Burning Life With Minimum @ L 70, The Colour Rendering Index Of Led Light Should Be More Than 70. Luminiare Comprises Of Driver, Pf> 0.95 & Surge Protection 10Kv. Housing Made Of Pressure Die Cast Aluminium With Heat Resistant Flat Glass, Ip65 Protection. Submission Lm 79-08 / Is16106 ( 2012 ) , Iec60598, Iec61347 I / C Connection Wire, Testing Etc. To Complete The Job. 10 60Watt, Color Temp 3000-6500K As Required. 11 Supplying And Fixing Flood Light With High Power Led Of 3 To 6 Watt Each Assembled On Single Mcpcb And Additional Unique Peanut Lens On Each Led, System Lumens Output With Efficacy>120 Lm / Watt. Luminiare Having Color Temp Upto 6500K & 50000 Hrs. Burning Life With Minimum @ L 70, The Colour Rendering Index Of Led Light Should Be More Than 70. Luminiare Comprises Of Driver, Pf > 0.95 & Surge Protection 10Kv. Housing Made Of Pressure Die Cast Aluminium With Heat Resistant Flat Glass, Ip65 Protection. Submission Lm 79-08 / Is16106 ( 2012 ) , Iec60598, Iec61347i / C Connection Wire, Testing Etc. To Complete The Job. 12 120Watt, Color Temp 3000-6500K As Required 13 Supply Of Xlpe Insulated Power Cable ( Conforming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor 14 25 Sq. Mm, 3½ Core Armoured 15 10 Sq. Mm, 4 Core Armoured 16 Laying Of One Number Armoured / Unarmoured Power Cable 1:1 Kv Grade Of Size Not Exceeding 25 Sq. Mm In The Existing Rcc Hume / Stone Ware / G.I. Pipe / Surface In Existing Trench As Required. 17 Laying Of One Number Armoured / Unarmoured Power Cable 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm Direct In Ground Including Excavation In All Soil / Murrum / Soft Rock, Sand Cushioning, Protective Covering And Refilling The Pit Etc. As Required. 18 Laying Of One Number Armoured / Unarmoured Cable 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm On Wall / Truss With Approved Type Of Iron Clamp Etc. As Required. 19 Supplying & Installing G.I. Pipe For Protection Of Underground Cable Fixed On Wall / Support / In Trench / Fixed Between Two Rigid Existing Support Of Wall / Beam For Erection Of Ceiling Fan / Down Rod For Stiff Pendent For Light Luminaries / Fan / Protective For Earthing, Lightening Conductor Down Strip / Overhead Service Line / For Submersible Cable Or Centrifugal Pump For Water Supply With Necessary Iron Clamp Coupler, Bend, Tee, Elbow, Nuts And Bolts Etc. Complete In An Approved Manner As Required To Complete Excluding Cost Of Excavation / Dismantling & Other Finished Masonry Item Complete. 20 50.00Mm, For B Class Pipe Isi Marked ( Is-1161- 68 ) 21 Supplying And Drawing Single Core Pvc Insulated Cable Frls With Copper Multi Strand Conductor Isi Marked In Existing Rigid Pvc Casing And Capping / Conduit In Surface Or Concealed As Per Specification. 22 3 X 2.5 Sq. Mm. 23 Supply Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker ( Mcb ) Of C Series With Short Circuit Indication, Suitable For 240 / 415 Volts, 50 Cycle, 10 Ka / 15 Ka Value Ac Supply Conforming To Is : 8828 : 1996, Iec : 60898 :2002 & 60947-2 But Without Enclosures :- 24 Mcb Sp 6Amp To 32Amp 10Ka Rating 25 Mcb Tp 50Amp To 63Amp 10Ka Rating 26 Mcb Fp 50Amp To 63 Amp 10Ka Rating 27 Supplying Of Isi Marked And Approved Make Of Moulded Case Circuit Breaker ( Mccb ) Suitable For 3 Phase, 3 Pole, 50 Hz, 415 Volts, ( Ics=100%Icu ) Ac Supply With Thermal - Magnetic Release Having Respective Breaking Capacity ( Ka ) At 415 Volts Cited Against Their Range Standard Conforming To Is / Iec 60947-2 28 Mccb 25Ka Current Rating - 125Amp & Adjustable Overload Setting 80% -100% Of In, Adjustable Short Circuit Setting 6-10 In 3 Pole 29 Fixing Of Mcb / Mccb / Isolator In Sheet Steel Enclosure As Required As Per Accepted Practice, Including Mounting On Busbar And Cable Connection Etc. Complete ( Labour Only ) 30 Mcb / Isolator Sp / Dp 31 Mcb / Mccb Isolator Tp / Tpn / Fp 32 Supply, Fixing, Testing & Commissioning Wall / Floor Mounted Lt Panel Primer Coated With Powder Coated Paint & Provided With Required Gasket For Dust / Vermin Proof With Degree Of Protection Ip42 Suitable For 415Volt 3 Phase, 50 Hz, 4 Wire System Fabricated Out Of Crca Sheet Upto 2 Mm Thick ( 1.6 Mm For Doors ) Duly Compartmentalized For Incomer, Bus Section, Outgoings, Cable Alleys & Ct, Pt Ampere Metre, Volt Metre, Selector Switches, Frequency Metre, Phase Indicating Lamp, Energy Metre Complete Including Cost Of Busbar Supports, Detachable Cable Gland Plates, 2 Earthing Terminals, Internal Wiring & Fixing Of Separately Supplied Mcbs, Mccbs, Acb, Panel Mounted Changeover Switch / Sfus, Etc. As Required But Excluding Cost Of Busbar Strips, Ampere Metre, Volt Metre, Selector Switch As Per Approved Design & Specification 33 Supply And Fixing Of Lt Panel Accessories Of Approved Make In Existing Lt Panel Including Connections Etc. As Required As Per Specification 34 Digital Ampere Metre With Cts With Selector Switch 35 Digital Volt Metre With Selector Switch & Hrc Fuse 36 Aluminium Bus Bar Strips With Pvc Sleeves 37 Led Lamp Indicator 38 Supplying And Fixing Of Cooler / A.C. M.S. Angle Iron Stand Including Flat Iron Supports, Grouting In Wall If Required, Welding, Painting With Primer And Two Coat Of Superior Quality Paint Complete. 39 Supply And Erection Of Approved Make Safe Earthing Electrode Consisting Pipe-In-Pipe Technology As Per Is 3043-1987 Made Of Corrosion Free G.I. Pipes With Constant Ohmic Value Surrounded By Highly Conductive Compound With High Charge Dissipation Suitable For Effective And Maintenance Free Earthing In Earth Pit Of Minimum Bore Dia. 150Mm Size, As Mentioned Below : 40 With 3 Metre G.I. Pipes Having Outer Pipe Dia Of 50Mm Having 80-200 Micron Galvanizing, Inner Pipe Dia. Of 25Mm Having 200-250 Micron Galvanizing, Connection Terminal Dia. Of 12Mm In Nominal Soil With 50 Kg ( Two Bag ) Back Filling Bentonite Compound Ul Listed And Confirm To Relevant International / Indian Standards Around Electrode Upto Ground Level. 41 Supply And Installation Of Polycarbonate Heavy Duty Pit Cover Tested For 5000Kg Swl For Earth Electrode At Ground Level Size 300X300x155 Mm With Lockable Lid. 42 Providing And Fixing 25Mm X 5Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode As Required