}

Tender For Supply Of Machineries And Equipments Required To Cancer Care Unit, Igh,Kvt Under Mplad Scheme, Kavaratti-Lakshadweep

Government Departments has published Tender For Supply Of Machineries And Equipments Required To Cancer Care Unit, Igh,Kvt Under Mplad Scheme. Submission Date for this Tender is 06-11-2023. Rechargeable Batteries Tenders in Kavaratti Lakshadweep. Bidders can get complete Tender details and download the document.




Tender Notice

40250434
Tender For Supply Of Machineries And Equipments Required To Cancer Care Unit, Igh,Kvt Under Mplad Scheme
Open Tender
Indian
Lakshadweep
Kavaratti
06-11-2023

Tender Details

Tender For Supply Of Machineries And Equipments Required To Cancer Care Unit, Igh,Kvt Under Mplad Scheme iBreast Exam Specification Type - Non invasive & Radiation free Model Type Handheld Technology used-Tactile sensors Storage Facility available - Device storage, Cloud Storage Device Storage capacity In Built for number of breast scans (minimum)- 50000 Device Cloud Storage capacity for number of breast scans (minimum) - 75000 Facility to print the final report - Yes Internet connection required to perform scanning - No Internet connection required to perform report generation-No Single sign-on facility to integrate the patient info into 3rd party healthcare applications - Yes Facility to integrate breast images into existing PACS systems of hospitals for follow-up-No Ability to integrate screening data into Government Dashboard Yes Application/Software availability-Android Application/Software runs on- Smartphone Functions available in the application/software-Perform breast Health examination, Review of Examination data Automated Screening Output Device type -Wireless Ext] Connectivity Bluetooth Sensitivity-80% Specificity - 90% Weight (approx)- s1kg Additional requirement- NA ELECTRICAL REQUIREMENTS Power source of the device Rechargeable battery Battery Chemistry-Li-polymer Battery Charging port type - USB 3.0 Battery capacity (mAH)-1000 to 2000 mAh HD Laryngoscope with Video Unit Specification Angle 70° enlarged view, diameter 3 mm, length 14 cm, autoclavable, fiber optic light transmission incorporated LCD SCREEN SIZE 3.5 Full View, Resolution Ration 640x480 RGB, Aspect Ratio 4:3 Video Refresh Rate 30FPS Illumination LED Screen is reinforced with antishatter protection Laryngoscope blade Camera- Included Resolution ratio 2.0 M Pixels, Field Angle 66, Illuminance 2800LUX Data Output image-Output Easy to Establish and store files Connect to External Moniter and convenient for training and presentation Chemotherapy Volumetric Infuser Pump Specification Flow rate programmable range at least from 0.1 to 200 ml/hr, in steps of 0.1 ml/hr, and at least from 100 to 1200 ml/hr in steps of 1 ml/hr. Saves last infusion rate even when the AC power is switched off Bolus rate should be programmable to approx. 500 ml, with infused volume display. Selectable occlusion pressure trigger levels selectable from 300, 500 and 900 mmHg Accuracy of 12% or better for set parameters. t] Maximum pressure generated 20 psi. Pause infusion facility required Self-check carried out on powering on. Comprehensive alarm package required including: occlusion alarm, near end of infusion pre-alarm and alarm, volume limit pre-alarm and alarm, low battery pre-alarm and alarm, AC power failure, drive disengaged It should be open system Flow rate programmable range at least from 0.1 to 200 ml/hr, in steps of 0.1 ml/hr, and at least from 100 to 1200 ml/hr in steps of 1 ml/hr. Saves last infusion rate even when the AC power is switched off Bolus rate should be programmable to approx. 500 ml, with infused volume display Selectable occlusion pressure trigger levels selectable from 300, 500 and 900 mmHg Accuracy of ±2% or better for set parameters. Maximum pressure generated 20 psl. Pause infusion facility required Self-check carried out on powering on Comprehensive alarm package required Including: occlusion alarm, near end of infusion pre-alarm and alarm, volun limit pre-alarm and alarm, low battery pre-alarm and alarm, AC powe failure, drive disengaged It should be open system. Pharmacy Refrigerator 120L Class-il biological safety cabinet Specification New and improved controller interface Easy to use switches and displays filter loading status Manually adjustable UV timer Optimum work zone brightness Ideal light intensity of 1200 lux Saves energy and optimizes work comfort Available in 8, 10, and 12 sash openings Frameless, shatterproof and UV-absorbing tempered glass Stainless steel side walls with side capture zones and negative pressure to optimize containment easy to clean Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor Extremely low energy consumption Standby mode allows reduced power consumption by 80% 10x filtration efficiency compared to the HEPA filter Creates ISO Class 3 work zone instead of industry-standard, ISO Class 5 Same 10 years filter life and replacement cost as HEPA filters Antimicrobial Powder Coating Eliminates 99.9% of surface bacteria within 24 hours of exposure Electric Chemotherapy Chair Specification Handset command permits individual adjustments of the sitting and lying positions for both patient and operator Thick padded sections for maximum comfort. •Wide padded armrests adjustable in three axis orientation. Adjustable easy to use headrest support Electrically controlled footrest variation. Height adjustment function permits easy seat access with a low minimum height setting • Centralized and direction lock with foot brake •Optional back up battery power supply. 150 mm twin wheels with central locking and steering lock. Simple design to facilitate cleaning and disinfection. Push/pull handle - optional. Side accessory bar support- optional. Synchronized operator command positions feature relax, bed, faint and shock. Five motors for maximum position adjustment.

Key Value

Document Fees
INR 1000 /-
EMD
INR 59000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail