Tender For Special Repair Of Office Shelters At Battalion Headquarter Of Sehlon Bn ( Manipur ) ; 1 Schedule‘A’ Part-I ( Repair / Maint Work ) 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm 3 Cement Concrete Pavement With 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishing Complete. 4 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 5 Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 6 Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint Onverlapping Of Sheets Complete ( Up To Any Pitch In Horizontal / Vertical Or Curved Surfaces ) , Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm / M² 7 Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is : 14616 And Tads 15:2001 ( Part B ) , Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, All Complete As Per Directions Of Engineerin-Charge And Panelling With Panels Of : 12 Mm Thick Plain Grade - 1, Medium Density Flat Pressed Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpti, Is : 3087 Marked, Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 : 8 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutterincluding Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within50 Metres Lead : 9 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodiccoating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 200X10 Mm. 10 Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised ( Anodiccoating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300X16 Mm 11 Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :125 Mm 12 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr / 10Sqm Over An Under Coat Of Primer Applied @0.75 Ltr / 10 Sqm Of Approved Brand And Manufacture 13 Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty: Float Glass Panes Of Nominal Thickness 4 Mm ( Weight Not Less Than 10Kg / Sqm ) 14 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade :New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coatwith Cement Primer 15 Finishing Walls With Textured Exterior Paint Of Required Shade :New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm 16 Point Wiring In Pvc Conduit, With Modular Type Type Switch, Wiring For Light / Fan / Exhaust Fan Point / Call Bell Point With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size M.S Box And Earthing The Point With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required 17 Wiring For Light / Power Plug With 2X4sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit Alongwith 1 No. 4 Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required 18 Supplying And Fixing3 Pin 5 / 6 Amp Socket Outlet On The Existing Switch Box / Cover Including Connections Etc. As Required 19 Supplying And Fixing Modular Switch / Socket On The Existing Moudlar Plate & Switch Box Incl Connections. ( 5 / 6 Amps Switch ) 20 Supplying And Fixing Modular Switch / Socket On The Existing Moudlar Plate & Switch Box Incl Connections. ( 15 / 16 Amps Switch ) 21 Supplying And Fixing 6Pin 15 / 16 Amp Socket Outlet On The Existing Switch Box / Cover Including Connections Etc. As Required 22 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 23 Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Moudlar Plate & Switch Box Incl Connections. 24 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2 + 6 Way, Single Door 25 Supplying And Fixing 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 26 Supplying And Fixing Blanking Plate On The Existing Moudlar Plate & Switch Box 27 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc Reqd. ( 4 Moudule ) 125Mmx75mm 28 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc Reqd. ( 12 Moudule ) 200Mmx75mm 29 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Incl Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection, Painting Etc As Reqd. 30 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Incl Providing And Fixing 6 Pin 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection, Painting Etc As Reqd. 31 Supplying And Fixing Brass Batten / Angle Holder Incl Connection As Reqd. 32 Installation, Testing And Commissioning Of Ceiling Fan Incl Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sqmm Fr Pvc Insulated Copper Conductor, Single Core Cable Etc. As Required.D.. 33 Earthing With Copperearth Plate 600Mm X 600Mm X3mm Thick Incl Accessories, And Providing Masonary Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe 2.7M Long Etc. With Charcol / Coke And Salt As Required. 34 Supplying And Laying 25Mm X 6Mm Copper Strip At 05 Meter Below Ground As Strip Earth Electrode, Incl Soldering Etc. As Reqd. 35 Supplying And Fixing 32 Amps Tpv, Switch Disconnector Fuse Unit ( Wall Mounted ) With Isi Marked. 36 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commisioning Etc. As Reqd. ( 63 Amps ) 37 Wiring For Circuit / Sub Main Wiring Alongwith Earth Wire With The Following Sizes Of Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Pvc Conduit As Reqd. ( 2X10sqmm + 1X10sqmm Earth Wire )