Tender For Improvement Of Cabling At Various Blocks In Rbipmt Hospital.; 1 122.1.17:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-3.5C*35 Sqmm 2 122.1.19:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-3.5C*70 Sqmm 3 122.1.23:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-3.5C*185 Sqmm 4 122.1.24:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-3.5C*240 Sqmm 5 122.1.25:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-3.5C*300 Sqmm 6 122.2.83:Supply, Installation, Testing And Commissioning Of Power Distribution Board Made Out Of 1.6 Mm Sheet Steel, Epoxypowder Coated , Specially Designed Al Bus Bar 400A To 630A With Heat Shrinkcable Colour Coated Sleeves Suitable For Accommodating Mccbs / Mcbs / Isolators As Incoming And Outgoing As Required ( Without Mccbs / Mcbs / Isolators ) Complete With Digital Meter Module, Including Voltmeter Ammeter With Selector Switch, Cts Control Fuse And Indicating Lights Including Connections Etc. As Required ( Conforms To Is:8623 ) 7 Od8938 / 2023-2024: ( Dsr-2022-7.1.1 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( A ) Upto 35 Sq. Mm 8 Od8939 / 2023-2024: ( Dsr-2022-7.1.2 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( A ) Above 35 Sq. Mm And Upto 95 Sq. Mm 9 Od8940 / 2023-2024: ( Dsr-2022-7.1.3 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( C ) Above 95 Sq. Mm And Upto 185 Sq. Mm 10 Od8941 / 2023-2024: ( Dsr-2022-7.1.4 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( D ) Above 185 Sq. Mm And Upto 400 Sq. Mm 11 Od8942 / 2023-2024: ( Dsr-2022-7.5.1 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( A ) Upto 35 Sq. Mm 12 Od8943 / 2023-2024: ( Dsr-2022-7.5.2 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( B ) Above 35 Sq. Mm And Upto 95 Sq. Mm 13 Od8950 / 2023-2024: ( Dsr-2022-7.5.3 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( C ) Above 95 Sq. Mm And Upto 185 Sq. Mm 14 Od8951 / 2023-2024: ( Dsr-2022-7.5.4 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. ( D ) Above 185 Sq. Mm And Upto 400 Sq. Mm 15 Od8954 / 2023-2024: ( Dsr-2022-7.6.1 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. ( A ) Upto 35 Sq. Mm 16 Od8955 / 2023-2024: ( Dsr-2022-7.6.2 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. ( B ) Above 35 Sq. Mm And Upto 95 Sq. Mm 17 Od8956 / 2023-2024: ( Dsr-2022-7.6.3 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. ( C ) Above 95 Sq. Mm And Upto 185 Sq. Mm 18 Od8957 / 2023-2024: ( Dsr-2022-7.6.4 ) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. ( D ) Above 185 Sq. Mm And Upto 400 Sq. Mm 19 Od8958 / 2023-2024: ( Dsr-2022-7.7.1 ) Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. ( A ) Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 20 Od8959 / 2023-2024: ( Dsr-2022-7.7.2 ) Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. ( B ) Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 21 Od8960 / 2023-2024: ( Dsr-2022-7.7.3 ) Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. ( C ) Above 95 Sq. Mm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 22 Od8961 / 2023-2024: ( Dsr-2022-7.7.4 ) Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. ( D ) Above 185 Sq. Mm And Upto 400 Sq. Mm ( Clamped With 40X3mm Ms Flat Clamp ) 23 Od8982 / 2023-2024: ( Dsr-2022-9.1.21 ) Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. ( A ) 3½ X 35 Sq. Mm ( 32Mm ) 24 Od8983 / 2023-2024: ( Dsr-2022-9.1.23 ) Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. ( B ) 3½ X 70 Sq. Mm ( 38Mm ) 25 Od8985 / 2023-2024: ( Dsr-2022-9.1.29 ) Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. ( D ) 3&Frac12; X 240 Sq. Mm ( 62Mm ) 26 Od8986 / 2023-2024: ( Dsr-2022-9.1.30 ) Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. ( E ) 3½ X 300 Sq. Mm ( 70Mm ) 27 Od8987 / 2023-2024: ( Dsr-2022-2.2.14 ) Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( A ) 125 A, 36Ka, Fpmccb 28 Od8988 / 2023-2024: ( Dsr-2022-2.2.16 ) Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( B ) 250 A, 36Ka, Fpmccb 29 Od8989 / 2023-2024: ( Dsr-2022-2.2.18 ) Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( C ) 400 A, 50Ka, Fpmccb 30 Od8990 / 2023-2024: ( Dsr-2022-2.4.1 ) Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( A ) 4 Way ( 4 + 12 ) , Double Door 31 Od8991 / 2023-2024: ( Dsr-2022-2.10.1 ) Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) Single Pole 32 Od8992 / 2023-2024: ( Dsr-2022-2.11 ) Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 33 Od8993 / 2023-2024: ( Dsr-2022-2.15.3 ) Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) 63 Amp 34 Od8995 / 2023-2024: ( Dsr-2022-2.24.1 ) Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc.As Required. ( A ) For 4 Way, Double Door Tpn Mcbdb 35 Od8996 / 2023-2024: ( Dsr-2022-5.2 ) Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 36 Od8998 / 2023-2024: ( Dsr-2022-5.9 ) Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 37 Od8999 / 2023-2024: ( Dsr-2022-5.15 ) Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 38 Od9000 / 2023-2024: ( Dsr-2022-7.9 ) Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. 39 Od9001 / 2023-2024: ( Dsr-2022-2.21 ) Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required.