Tender For Repairs To Wiring Of Mta ( Tw ) Workshop At Mpf Ambernath; 1 Repairs To Wiring Of Mta ( Tw ) Workshop At Mpf Ambernath 2 Supply & Fixing Sheet Metal Enclosure, Double Door, 415Vac, Three Pole & Neutral 4 Way, Single Plate, Make:Siemens / Schneider / Legrand / L&T All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 3 Supply And Fixing 415V 10Ka B Curve Miniature Circuit Breaker ( Mcb ) Of Tpn And 16 - 32 Amp Current Carrying Capacity Make:Siemens / Schneider / Legrand / L&T In The Db Complete With Connection Testing And Commissioning All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 4 Supply And Fixing 240V 10Ka B Curve Miniature Circuit Breaker ( Mcb ) Of Sp And 5-32 Amp Current Carrying Capacity Make:Siemens / Schneider / Legrand / L&T In The Db Complete With Connection Testing And Commissioning All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 5 Supply And Fixing Of4 Pole, 415 V, 63 Amp, 16Ka, Make: L&T / Schneider / Abb / Siemens, Works Include Termination Of Incomming And Outgoing Cable In Suitable Mcb Mounting Box All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 6 Supply And Fixing Of Xlpe Insulated, Armoured Heavy Duty Electric Cable 4 Core With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 10 Sq. Mm ( Make:Finolex / Polycab / Havells ) Etc All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 7 Wiring For Circuit / Submain Wiring Along With Earth Wire With 2 X 2.5 Sq.Mm+ 1 X 1.5Sq.Mm Earth Wire Of Fr Pvc Insulated Copper Conductor ( Make:Finolex / Polycab / Havells ) In Pvc Conduit Pipe Of Min. Thickness 1.5 Mm, Make: Precision / Pressfit / Finolex All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 8 Fixing Only 120 Watts Led Highbay Fixtures ( M.D Supply ) Complete With All Accessories Prewired And Including Connectingup With Three Core Flexible Copper Conductor Cable With Suitable Size In Fexible Conduitand Connector All Complete As Directed By The Engg In Charge 9 Material And Labour For Boxes Junctions, Plastic, Round, Four / Two Terminals, 1.5 Mm Thickness, For Mounting Of Ceileing Rose All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 10 Material And Labour For Ceileing Rose, 3-Phase / Pvc / Polycarbonate, Isolated Body All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 11 Dismantling And Taking Down Fluorescent Tube Light Single / Double Of Any Wattage Or Size Of Burnt / Worn Out Accessories Repair Or Carrying To Store All Including Connected Wire, Conduit Pipe And Switch Socket Board Etc. All Complete As Directed By The Engg In Charge 12 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Removing Materials To Store For Keeping In Safe Custody For Reuse At Site And Making Good Disturbed Surfaces Of Walls, Floors, All Complete As Directed By The Engg In Charge 13 Taking Down Carefully By Unscrewing From Boards / Outlet Boxes, Fittings And Fixtures Such As Switches, Sockets, Ceiling Roses, Lamp Holders, Brackets, Ceiling Fittings, Bulk Head Fittings, Tube Light Fittings And Regulators, Etc. For Reuse At Site Or Carrying To The Store ( To Be Measured Only When Found Serviceable In All Respects Complete For Reuse ) All Complete As Directed By The Engg In Charge 14 Dismantling Air Break Gang Operated Switches Vertical / Horizontal Mounted Including Insulators And Operating Mechanism For Repair / Replacement Of Broken / Worn Out Components And Insulators Etc. Or Carrying To Store ( Spare / Components For Replacement To Be Provided Free By Department ) All Complete As Directed By The Engg In Charge 15 Supply And Installation Of M.S Pendant Of Length 1.0 Meter Approx., Od 20Mm, Pipe Thickness: 2 Mm, Mounting With I-Beam And Provision Of Hook For Holding Highbay Led Fittings Of 10Kg Weight. Two Hole At Corne Of Pipe For Supply Cable Entry, Connection To Led Light Fitting Is Through 3 Pin Straight Connector Alongwith Safety Chain In Additional All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 16 Supply Of Metal Enclosure For Mounting Of 4P Mcb, Make: Siemens / Schneider / Legrand / L&T / Havells All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing. 17 Supply Of Highbay Led Light, 150W, Voltage: 230-270Vac, Color Temperature: 6000K, Ip65 Protection, Surge Upto >=5Kv, Shape Of Luminaire: Round, With I-Bolt And Mounting Brackets, Control Gear: Constant Current, Warranty: 5 Years, Make: Orient / Surya / Crompton / Havells / Phillips All Complete As Directed By The Engg In Charge.Note: Sample Of All Materials Shall Be Got Approved From Eic Before Fixing.