| 1 | SITC of 1.5TR capacity concealed type Split Air Conditioner(R-32) 3-Star of 22-23 of rated cooling capacity of 18000 BTU/hr. with 1Nos. rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz.Air-flow/per IDU:- 650CFM.( Make: Hitachi/Mitsubishi-Electric/O-General) |
| 2 | Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku) |
| 3 | a) Liquid Line (1/4\" OD with 0.6 mm thick) |
| 4 | b) Suction Line (5/8\" OD with 0.7mm thick) |
| 5 | Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex) |
| 6 | a) Liquid Line(1/4\" OD with 0.6 mm thick) |
| 7 | b) Suction Line (5/8\" OD with 0.7mm thick) |
| 8 | Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex) |
| 9 | a) 4 core 2.5 sq.mm communication cable |
| 10 | S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. |
| 11 | a) 25 mm dia |
| 12 | Charges for scaffolding arrangement incl. lifting for outdoor & indoor units |
| 13 | Dismantling the existing 8 Nos.AC machine IDU,copper pipe line and ODU incl. and kept them to deopartmental store room, mending good damages as per direction of the EIC. |
| 14 | SITC of 17 TR capacityAir Cool package unit having refrigerant (R-410A) of rated cooling capacity of 204000BTU/ Hrwithtwo Nos.hermetic scrollcompressor, with rated IDU power 430V, 50Hz, AC, ODU power 230V, 50Hz, Air-flow per IDU:- 6800CFM. Including first charging of refrigarent (407C/410A) ( Make: Voltas/Mitsubishi-Electric/O-General/Blue Star) |
| 15 | Supply & Fixing Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku) |
| 16 | a) Liquid Line (5/8)\" OD with 0.8 mm thick Cu.pipe) |
| 17 | b) Suction Line (1 / 1/8\" OD HD with 1 mm thick Cu.pipe) |
| 18 | Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex) |
| 19 | a) Liquid Line (5/8)\" OD with 0.8 mm thick ) |
| 20 | b) Suction Line (1 / 1/8\" OD HD with 1 mm thick ) |
| 21 | Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex) |
| 22 | a) 4 core 2.5 sq.mm communication cable |
| 23 | Supply & delivery of refrigerant R-410 for concealed type Split Air Conditioner |
| 24 | S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. |
| 25 | a) 32 mm dia |
| 26 | DUCT WORKSupply, installtion, testing and commissioning of Class - VIII grade (120 GSM) supply & return air duct along with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges.(MAKE - SAIL / TATA) |
| 27 | 20 SWG |
| 28 | 22 SWG |
| 29 | 24 SWG |
| 30 | S & F of 13 mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on new duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete Make - Armacell / K Flex / Supreme/A-Flex |
| 31 | Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required.Make - Armacell / K Flex / Supreme/A-Flex |
| 32 | Supplying, fixing, testing & commissioning of powder coated extruded aluminium section supply air diffuser with M.S volume control dampers as required. Make - Systemair /Green Air/ADS / Dynacraft / Premire / Caryaire / Airmaster |
| 33 | Supplying, fixing, testing & commissioning of powder coated extruded aluminium section return air diffuser but without volume control dampers as required. Make -Systemair /Green Air/ADS / Dynacraft / Premire / Caryaire / Airmaster |
| 34 | Supply, installation, testing and commissioning of opposed type Duct dampers GI mannual type. Make - Systemair /Green Air/ADS / Dynacraft / Premire / Caryaire / Airmaster |
| 35 | Supply, installation, testing and commissioning of fusible type Fire Damper made out of 18G GI sheet. Make - Systemair /Green Air/ADS / Dynacraft / Premire / Caryaire / Airmaster |
| 36 | Supply and fixing flexiblecanvass connection for concealed splitair-conditioners. |
| 37 | Civil Work for incoming return duct and outgoing duct |
| 38 | Rate should be quoted incl. of all taxes and cess. |
| 39 | Defect Liability period : 1 year |