}

Repairing / Replacement Of Damaged ( Em ) Equipments At B1 New Ashok Nagar And B2 New Ashok Nagar Tube Well Under Ac ( 56 ), vihar-Delhi

Boards / Undertakings / PSU has published Repairing / Replacement Of Damaged ( Em ) Equipments At B1 New Ashok Nagar And B2 New Ashok Nagar Tube Well Under Ac ( 56 ). Submission Date for this Tender is 13-10-2023. Tube Well Tenders in vihar Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40102875
Repairing / Replacement Of Damaged ( Em ) Equipments At B1 New Ashok Nagar And B2 New Ashok Nagar Tube Well Under Ac ( 56 )
Open Tender
Indian
Delhi
Vihar
13-10-2023

Tender Details

Repairing / Replacement Of Damaged ( Em ) Equipments At B1 New Ashok Nagar And B2 New Ashok Nagar Tube Well Under Ac ( 56 ) -Lifting Of P / Set By The Help Of Chain Pulley, Clamps And Heavy Men Manpower After Cutting Rusted / Worn-Out And Opening Of Nut Bolts To Dismantle The P / Set, Pipes, Valvesetc. 2 Renovation / Repairing Of 7.5 H.P, 80Mm Dia. Submersible Pump Set Havingwork Of Rewinding Of Motor, Cable 6 Sq. Mm, 6 Mtr., Replacement Of G.M Bearing Bushs, Upper Bushs, Guide Bushs , Distance Bush And Balancing Of Rotor With Rotor Sleeve Turning & Grinding And Also Repairing Of Impeller. The Job Also Includes The Labour Charges For Rewinding / Repairing Of P / Set. 3 S / O Submersible Cable With Copper Conductor Having Three Core Sizes 6 Sq. Mm Working On 1100V. Make:-Finolex / Plaza / Unistar Or Any Other Make Approved By Djb. 4 Supply Of Clamp Of M.S Strip 8Mm Thick Duly Hole For Holding The Pipe Of 80Mm Dia With Nut Bolt And Washer 5 S / O Nrv 80 Mm Dia Ci Double Flanges Pn1.0 Make:-Kirloskar / Ivc Or Any Other Make Approved By Djb. 6 S / O Ci Sluice Valve, Non Rising S.S. Spindle, D / F P.N 1.0 Of Size 80 Mm Make:- Kirloskar / Ivc Or Any Other Make Approved By Djb. 7 S / O Ci Bend 80 Mm Dia 90Deg. Double Flange. Heavy Class Make: - Ganesh / Isi 8 S / O Of 3 Mtr. ( 10Ft ) Gi Pipe 80 Mm Dia Size , Medium Class With Gi Flange Welded In Both Sides 3 Mtr Long With Ms Strips Complete With Threading Work On Each Side Of Pipe Each Flange Should Be 4 Holes And Cut For Cables. Make :- Jindal / Tata. 9 S / O G.I Required Off Size Threaded Heavy Duty Nut-Bolts Of Good Quality. 10 Supply Of M.S Bore Cover Made Out Of M.S Plate Suitable For 10 Dia Bore Complete With Suitable Hole For Passing The 80Mm Dia Gi Pipe. 11 S / O Pressure Gauge Of 80 Mm Dia, 0-30 Psi Complete With Socket, Bush Make:-H-Guru / Fiebig 12 Making Water Sample Point With The Help Of Socket, Niple, Cook Valve, Tee And Extended Pipe Etc. Of Size 1 / 2 Inch. 13 Making And Supply Of G.I Tail Piece Of 80 Mm Dia. , 0.5 Mtr. Long Size Made Out Of Medium Class Pipe Complete With One End Threaded And Other End Fitted With G.I. Flange Heavy And Cut For Submersible Cable. Mak Of Pipe - Jindal / Tata. 14 Supply Of Distribution Panel Baord For Automation Of Operation Of T / Well Upto 10 Hp Submersible Pump Set Having Sheet Enclosure Made Out Of 16 Swg Sheet And 50 X 50 X6 Mm Angle Iron And Size 1000X750x300mm With 02 Feet Long Legs Stand, Totally Enclosed, Power Coated Free Standing Floor Mounted Type, Dust & Vermin Proof, Out Ward Opening Lockable Door Having Hidden Hing And Bolted Back Cover Both Using Non-Deterioratiing Neopreme Rubber Gasket. The Various Components And Sub Equipment Of The Panel Will Be Shaped Out Of High Conductivity Electrolyte Aluminnium Conductor And Shall Be Liberal Size. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Wire Of 1.5 Mm2each Wire Will Be Terminating A Ferule Crimped To The Wire Having The Following Components.:- Mccb, Tpn Of 100A Breaking Cap, 25 Ka Sutable For Motor Protection -1 No.Make L &T / Havell’S-. Power Contactor 32 A. Triple Pole – 2 Nos.Makel &T / Havell’S Ampare Meter ( 0-30A ) 4’’ Size Squ. Type---1No.Makel&T / Ae Voltmeter ( 0-500V ) 4’’ Size Squ. Type ----1No.Make Ae / L&T1 No. Indicating Lamp Set For Ryb Phase--01 Set Make L &T / Havell’S Single Phase Preventor--01 No.Makel&T / Sien Time Switch Digital / Anolog Type-- 01 No.Makel&T / Havell’S Over Load Relay Thermal Type 14-23 A -1No.Make L &T / Havell’S Star Dalta Timer On Delay--01 No.Makel&T / Havell’S Automanual Switch 2 Position Selector Switch Center Off With No + Nc Block-1No.Makel&T / Havell’S Three Pole Power Contractor -25A Cap. --01 No.Makel&T / Havell’S Tp Mcb Of 63 Amp. Capacity -- 01 No.Makel&T / Havell’S Supply Of Changeover Switch 63 Amp, Capacity Four Pole – 1 No Power Capacitor Of 05 Kvar. 415 Volt 50Hz Ac Supply--01 No.Makel&T / Havell’Sthepanel Should Start & Stop Automatically As Per Timing Set In This. It Should Also Re -Start Automatically On Resumptions Of Power In Case Of Power Failure 15 Supply Ofneoprene Rubber Sheet Having 50% Neoprene , 3 Mm Thick Make Jyoti / Worth / Djb Approved 16 Supply And Fixing ( Permenaent ) Of Electric Insulated Sheet For Ac & Dc Which Is Moisture Proof, U.V. Protected, Fire Retardant, High Di-Electric Strength, Easy To Clean, Auto Glow Path, Coloured Strips On Both Sides, Glow In Emergency, Cpri Approved, Confirming To Bisdoc No. Et-02 ( 5440 ) . Dt: 30-04-04, Meeting Requirement Of Is:3043, Is:5216 ( Part 1, 2 & 3 ) , Is: 8437 And Iec: 479 Pub-1 Tested For Breakdown Strength Tensile, Elongation Aging Properties, Insulation Resistance Effect Of Acid, Alkaline, Diesel And Transformer Oil, Leakage Current Test Etc. 1 No. = 1Mtr. Breadth X 2 Mtr. Length. Make: Electromat / Safevolt 17 Installation Of All E&M Equipments, Lowering Pump Set Into The Bore All Piping Work Fixing Of Valves And Accessories Executing Minor Civil Works, Making Electrical Connections With Cable As Required Size By The Help Of Chain Pully To Lower Pump Sets Testing And Commissioning Of All E&M Equipments At No Load And Full Load Conditions As Per Standard From Full Satisfaction Of Engineer-In-Charge.The Job Also Includes The Transportation Charges, Providing / Fixing Of Required Gap Piece, For Fixing Valves, Pressure Gauge With The Help Of Welding Machine Etc.

Key Value

Document Fees
INR 500 /-
EMD
INR 10400.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail