| 1 | Loading/Unloading & opening of Transformer Cover,draining oil if any, detanking core and coil assembly ,assessment and estimation for repair and replacement of parts, cleaing andwashing of dust/rust and dirt from all other parts including core tanks and cooling tubes, retankingafter replacement of parts/repairs as required filling fresh/new filtered Transformer oiltaking of transformer for test and testing for all the routine test as in case of new transformer as per relevant ISS & after satisfactory repairs & testing, marking & providing blue paint etc.loading of transformers at the contractor\"s works(Price variable with base date 01.08.2023 ). |
| 2 | FOR BOTH ALUMINIUM AND COPPER WOUND DISTRIBUTION TRANSFORMERS |
| 3 | a) 5 KVA |
| 4 | b)10/16/25KVA |
| 5 | HV leg coils with insulation , varnishing and packing of coil assembly Vaccum impregnation/Oven dried) (Price variable with base date 01.08.2023) |
| 6 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
| 7 | ALL(For AL wound) |
| 8 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
| 9 | ALL(For Cu wound) |
| 10 | LV leg coils with insulation ,varnishing and packing of coil assembly Vaccum impregnation/Oven dried) (Price variable with base date 01.08.2023) |
| 11 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
| 12 | ALL(For AL wound) |
| 13 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
| 14 | ALL(For Cu wound) |
| 15 | HT Bushing(11 KV) as per relevent ISS |
| 16 | 5 kva to 25 KVA (For both Aluminimum & Coppper wound Distribution Tranformer) |
| 17 | LT Bushing (0.433 KV) & Neutral bushing as per relevent ISS |
| 18 | 5 kva to 25 KVA (For both Aluminimum & Coppper wound Distribution Tranformer) |
| 19 | Bushing Rod and other metal parts including nuts( indicate material and size of bushing Rod) |
| 20 | i) For HV Bushing |
| 21 | 5 kva to 25 KVA (For both Aluminimum & Coppper wound Distribution Tranformer) |
| 22 | ii) For LV bushing |
| 23 | 5 kva to 25 KVA (For both Aluminimum & Coppper wound Distribution Tranformer) |
| 24 | Set of Gaskets(Rubberised cork/ Neoprine) material & size is to be indicated |
| 25 | 5 kva to 25 KVA (For both Aluminimum & Coppper wound Distribution Tranformer) |
| 26 | Glass for Oil level gauge |
| 27 | ALL(For AL and CU wound) |
| 28 | Oil drain /filter valve(material & size is to be indicated) |
| 29 | ALL(For AL and CU wound) |
| 30 | Fresh/ new filtered transformer oil of standard quality with ISI mark ) (Price variable with base date 01.08.2023) |
| 31 | For all type of Transformers |
| 32 | LT terminal plate with terminals if required |
| 33 | ALL(For AL wound) |
| 34 | Sundry items viz. cover bolts, plug cap screw, washers, insulation material, pressure release valve etc. Please indicate list of Item included in sundry item parts if any,(denting/ welding etc if required) |
| 35 | ALL(For AL and CU wound) |
| 36 | Painting of Transformer |
| 37 | Inside with one coat with primer & two coat of Zinc Cromate best paint. |
| 38 | For both Aluminimum & Coppper wound Distribution Tranformer |
| 39 | a) 5 KVA |
| 40 | b) 10 KVA |
| 41 | c) 16/25 KVA |
| 42 | Out side of transformer with primer andtwo coats of grey paint and marking after de rusting |
| 43 | For both Aluminimum & Coppper wound Distribution Tranformer |
| 44 | a) 5 KVA |
| 45 | b) 10 KVA |
| 46 | c) 16/25 KVA |
| 47 | Filteration charges of new transformer oil . (if supplied by nigam) |
| 48 | M&P Box unit complete with MCCB |
| 49 | For all ratings of Copper wound Distribution Transformer |
| 50 | M&P Box unit |
| 51 | For all ratings of Aluminium wound Distribution Transformer |
| 52 | Internal circuit breaker(ICB) |
| 53 | Only for all ratings of Aluminium wound Distribution Transformer |
| 54 | Fixing Charges of Meter and Protection (M and P ) Box |
| 55 | For all ratings of both Aluminimum & Coppper wound Distribution Tranformer |
| 56 | Signal Light (For all ratings of both Aluminimum & Coppper wound Distribution Tranformer) |
| 57 | Fuse Wire on HT side (For all ratings of both Aluminimum & Coppper wound Distribution Tranformer) |
| 58 | Mounting arrangements |