Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Business Plan Scheme In The Area Of Ee, Eudd I, Mathura Under The Jurisdiction Of Se, Eudc, Mathura- 1 Cartage Of Following Material From Store Centre, Mathura To Work Site. 2 St Pole ( 11 Mtr. Long ) ( Sp-55 ) Bottom Portion Galvanized 3 St Pole ( 13 Mtr. Long ) ( Sp-70 ) Bottom Portion Galvanized 4 11 / 0.4 Kv 400 Kva T / F 5 11 / 0.4 Kv 250 Kva T / F. 6 11 / 0.4 Kv 100 Kva T / F. 7 Lt Xlpe / Pvc Cable 1Cx630 Sq.Mm. 8 Lt Xlpe Cable Of Size 3.5X240 Sq. Mm. 9 Lt Xlpe Cable Of Size 3.5X150 Sq. Mm. 10 Lt Xlpe Cable Of Size 3.5X70 Sq. Mm. 11 2Cx10 Sq.Mm. Armoured Cable 12 4X10 Sq.Mm. Armoured Cable 13 33 Kv Xlpe Cable 3X300 Sq.Mm. 14 11 Kv Xlpe Cable 3X185 Sq.Mm. 15 11 Kv Xlpe Cable 3X120 Sq.Mm. 16 11 Kv Vcb For O / G Ctr 200 / 100 / 5A, 350 Mva 17 33 Kv Control Panel For Double T / F 18 Acsr Dog Conductor 19 Acsr Ins. Weasel Conductor 20 33 Kv Ligtening Arrestor 21 33 Kv Fuse Set 22 33 Kv Line Isolator 800 Amp. 23 33 Kv Post Insulator 24 G.I. Wire For Guarding Angle 25 Cable Jointing Kit 33 Kv 3X300 Sq.Mm. O / D 26 Cable Jointing Kit 33 Kv 3X300 Sq.Mm. S / T 27 Cable Jointing Kit 11 Kv 3X120 Sq.Mm. O / D 28 Cable Jointing Kit 11 Kv 3X120 Sq.Mm. S / T 29 Cable Jointing Kit 11 Kv 3X185 Sq.Mm. O / D 30 Cartage Of Above Material Like Various Size 33 Kv, 11 Kv Cable, Dog / Weasel Conductor, Jointing Kit, Vaccume Interrupter, Distribution Transformers, St / Pcc Pole, Insulator, Control Panel, Pin Insulator, Bus Isolator, Brass Glands, Channel, Clamps Etc. From Store Center, Mathura To Work Site And Dismentled Material From Site To Dvvnl Store. 31 Digging Of Pit & Erection Of New Single Support St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 32 Digging Of Pit & Erection Of New Double Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 33 Grouting Of St Pole With Cement, Sand, Concrete, ( Cc Will Be Of Cement, Coarse Sand & Brick Balleast Grouting Will Be Done With The Help Of Wooden / Steel Formers In A Block Of Size 900Mm X 450Mm X 1 / 3 Of The Full Of The Support In The Cc 1:4:8 As Per Relevant Drawing Including Back Filling & Proper Ramming. 34 Providing & Fixing / Installation Of 33 / 0.4 Kv, 250 Kva S / S 35 Providing & Fixing Of M.S. Top Channel ( 125X65x3200 Mm ) 36 Providing & Fixing Of M.S. Top Channel ( 125X65x2240 Mm ) 37 Providing & Fixing Of M.S. Dropper Channel ( 100X50x2028 Mm ) 38 Providing & Fixing Of Ms Angle ( 65X65x6x3800 Mm ) Bracing Set With 04 No. Clamp 39 Providing & Fixing Of Ms Angle ( 65X65x6x2700 Mm ) Bracing Set With 04 No. Clamp 40 Providing & Fixing Of M.S. Angle For T / F Base 41 Providing & Fixing Of M.S Tee Chanel With Clamp & Nut Bolts, WasherS. 42 Fixing / Installation Of 33 Kv L.A. 43 Fixing / Installation Of 11 Kv Vcb For O / G Ctr 200 / 100 / 5A, 350 Mva 44 Earthing Of St / Pcc Pole / Body Earthing Of T / F. By M.S Earth Rod. 45 Providing & Fixing Of Ms Nut, Bolt And WasherS 46 Painting Of St Pole. 47 Digging Of Pit & Erection Of Stay Rod With Grouting Cement Sand And Brick Ballast Including Nuzzling, Binding Complete. ( Stay Insulator Providing By Contractor ) 48 Overhauling Of 08 Mva Power T / F At 33 / 11 Kv S / S Cannt, Mathura Including Following Works With Required Accessories. 49 Opening Of All Connection Of 08 Mva Power Transformer 50 Drain Out Of Transformer Oil For Replacement Of Damaged Packing 51 Lifting Of Top Cover By The Help Of Crain For Replaceement Of Damaged Packing Of Top Cover, Inspection Plate Including Removal Damage Packing And Surface After Then Fixing Of New Packing And Top Cover, Inspection Plate Including Tighting Of Nut & Bolts. 52 Replacement Of Lt Side Rod 53 Opening Of Radiator And Removal Of Damage Packing 54 Fixing Of New Packing Radiator And Fixing Of Radiator Of 08 Mva T / F 55 Opening Of The Conservator Tank By The Help Of Crain Removal Of Damage Packing Cleaning Of Surface Fixing Of New Packing And Fitting Of Conservator Tank 56 Opening Of 33 Kv, 11 Kv Bushing Rod Very Carefully And Removal Of Damage Packing And Replacement Of New Packing And Fixing Of 33 Kv, 11 Kv Bushing Rod Complete. 57 Filling Of Transformer Oil 58 Making Of All Connection Of 08 Mva Power Transformer 59 Connection Of 33 Kv Isolator, Post Insulator, Fuse Set, Transformer By The Fitting Of Connecting Clamp 60 Water Level Earthing Complete 61 Laying Of 2Cx10 Sq.Mm. Amoured Cable 62 Laying Of 4X10 Xlpe Amoured Cable With Catenary 63 Providing & Fixing Of Pvcpipe 2 Diameter 64 Providing & Fixing Of Pvcpipe 3 Diameter 65 Providing & Fixing Of 10 Sq.Mm. Aluminium Thimble 66 Providing & Fixing Of 16 Sq.Mm. Aluminium Thimble 67 Providing & Laying Of 33 Kv Xlpe Cable 3X50 Sq.Mm. 68 Providing & Fixing Of 33 Kv Xlpe Cable J / K. 3X50 Sq.Mm. O / D & I / D 69 Special Plinth For 630 Kva T / F Construction Of Distribution T / F Foundation And Plinth On Rcc Pillar As Per Mentioned And Provided Dimensions Drawing Structure And Specified Details For The Same. Due To Exception Case To Be Taken Food Suumerzed Area World Level Monumentle Temple Situation And Safety Purpose. 70 Sagging Of 33 / 11Kv Line On Dog Conductor On Erected Poles. 71 Jumpering / Fixing By Acsr Ins. Weasel Conductor On T / F, D / P, T / P, F / P. Etc. 72 Laying Of Lt Xlpe / Pvc Cable 1Cx630 Sq.Mm. 73 Laying Of Lt Xlpe / Pvc Cable 3.5Cx400 / 240 / 150 / 70 Sq.Mm. 74 Stringing & Sagging Of G.I. Wire For Guarding ( 6&10 Swg ) With Biding The Arrows ( Tilli Distance Appr. 02 Mtr. ) 75 Providing & Fixing Of Guarding Angle For 33 / 11 Kv Line 76 Providing & Fixing Of I Bolt For Guarding 77 Providing & Fixing Of Aluminium Biding Wire For Guarding 78 Providing & Fixing Of Aluminium Biding Wire 6 Swg 79 Providing & Fixing Of Clamp For Guarding Angle For 11 Kv Line 80 Installation Of Distribution Box On St Pole / Pcc Pole For Lt Line. 81 Providing & Fixing Of Earth Wire Clamp 82 Providing & Fixing Of Armoured Rod With Ferules For 33 Kv ( Dog ) 83 Providing & Fixing Of Danger Board 84 Providing & Fixing Of Barbed Wire 85 Providing & Fixing Of Stone Pad 86 Providing & Fixing Of P.G. Clamp For 33 Kv & 11 Kv Line 87 Painting Of Subsation Structure 88 Providing For Clamp For Hdpe Pipe 89 Providing & Fixing / Installation Of Lt Protection For 250 Kva T / F ( As Per Technical Specification ) 90 Providing & Fixing Of Number Plate For Yard Equipment Of Nomeclature 91 Providing & Fixing Of Buchholz Relay For Control Panel 92 Fixing / Installation Of 33 Kv Fuse Set 93 Providing Of Structure For 33 Kv Fuse Set 94 Fixing / Installation Of 33 Kv Line Isolator 95 Providing Of Structure For 33 Kv Line Isolator 96 Fixing / Installation Of 33 Kv Post Insulator 97 Providing Of Structure For 33 Kv Post Insulator 98 Providing, Fixing / Filling Of Breather For Power T / F With Silca Gel 99 Providing & Fixing Of G.I. Pipe With Capping 100 Providing & Fixing Of G.I. Pipe Clamp 101 Fixing Of 33 Kv V Type Steel Cross Arm 102 Fixing Of 11 Kv V Type Steel Cross Arm 103 Fixing Of 11 Kv Pin Insulator With Pin 104 Fixing Of 33 Kv Pin Insulator With Pin 105 Fixing Of Disc Insulator 45 Kn & 70 Kn ( T&C / B&S ) 106 Fixing Of Disc Fitting 45 Kn & 70 Kn ( T&C / B&S ) 107 Providing & Fixing Of 33 Kv Kv F Bracket 108 Providing & Fixing Of 11 Kv Kv F Bracket 109 Providing & Fixing Of Packing Piece Clamp For 33 Kv / 11 Kv / Guarding With Nut & Bolts 110 Providing & Fixing Of Aluminium Lug 630 Sq.Mm. 111 Providing & Fixing Of Aluminium Lug 240 Sq.Mm. 112 Providing & Fixing Of Aluminium Lug 150 Sq.Mm. 113 Providing & Fixing Of St Pole Clamp 114 Providing & Fixing Of Hot Dip Galvanized Cable Support Clamp For Cable 115 Filling & Fixing Of Cable Jointing Kit 33 Kv 3X300 Sq.Mm. Outdoor Type 116 Fixing Of 33 Kv Straight Through Of Size 3X300 Sq.Mm. 117 Filling & Fixing Of Cable Jointing Kit 11 Kv 3X120 Sq.Mm. Outdoor Type 118 Fixing Of 11 Kv Straight Through Of Size 3X120 Sq.Mm. 119 Filling & Fixing Of Cable Jointing Kit 11 Kv 3X185 Sq.Mm. Outdoor Type 120 Providing & Fixing / Installation Of C Type Lt Paneldisconeccting And Dismentlingof Existing C Panel And Supply, Installation Testing Commisioning Offactory Fabricated&Wired Metalcladdustandverminproof Double Door Typeoutdoor Application Stand Mounting, M.S. Channel Base Incliding Channel Stand With Bottom Cable Entreis The Panel Boardshall Havesuitablecapacity Electrolytic Alumininum Busbars Asper Is8623 Or Above Istulated With Heat Shrink Sleeving And Mounted On Nonhygroscopic Supports Such As Cmc / Bmc Support. Panel Shall Be Completewithsuitablecableendboxes, Double Compression Glands. Panel Comparment Having Special Provision For Internal Locking System For Stop The Electricity Theft The Panelboard Shall Be Fabricated With Gelvnized Prime Sheet With A Minimum Thickness Of 1.6Mm / 2Mm. With Seven Tank Process Powder Coated. Panel Haveing Proper Space For Connectingincomming And Outgoing Cable Terminations. 121 Providing & Laying Of Hdpe Pipe 160 Mm Od Pn-4 Pe-80 Grade Uv Stabilized Hdpe As Per Is: 4984 Of 6 Meter Length 122 Horizontal Drilling Underground Installation Piping Hdpe Pipe 160Mm Dia With Minimum Depth Of Pipe 1.2 Below Surface For Double Circuit Length Of Line 123 Laying Of 33 / 11 Kv Xlpe Cable In Hdpe Pipe / Trench / Double Pole Structure / Loop Etc. 124 Digging Of Trench By Excavation Of Earth 0.90 / 1.5 Mtr. Deep Put Brick On Both Side, Filling Of Sand & Brick On Cable & Earth Ramming And Dressing Properly With Complete Job For Laying 33 / 11 Kv Xlpe Cable In Trench 125 Laying Of U / G Lt Xlpe Cable 3.5X70 / 150 / 240 With Complete Job 126 Installation Of D.O. Fuse Set Of 11 Kv 127 Concreting Of Pole ( St 13 Mtr. / 11 Mtr. ) Pcc Pole 128 Removal Of Old Transformer ( 250Kva ) With All Connected Accessories From Existing Plinth. 129 The Construction Of New Plinth Of Size 5’X5’X4’ Aboveground Level And One Ft. Below The Ground Level For 400 / 250 Kva Transformer 130 Installation Of Following Transformer On Plinth / Double Pole With All Connecting Accessories Jumering Etc. Including Carriage Of Transformers From Store Centre, Mathura To Work Site. 131 400 Kva Transformer On Plinth 132 250 Kva Transformer On Plinth 133 100 Kva Transformer On Double Pole Structure 134 Providing And Installation Of Tail Less Unit Complete 135 Construction Of M.S Angle Fencing Of Size ( 3M X3m X2m ) Around The Plinth Of 400 / 250 Kva Transformer And Gap Between The M.S Angle Should Not Be More Than 65Mm. 136 Complete Gel Earthingof 11 / 0.4 Kv 250 / 400 Distribution Transformer By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1.Earth Pipe Material – Mild Steel, Galvanised.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm.4-Wall Thickness Of Main Electrode :- 2.6Mm.5-Wall Thickness Of Auxiliary Ist Whole:- 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 137 Proper Road Restoration Kaccha / Pakka ( After Completion Of 33 Kv & 11 Kv Line Work ) 138 Dismantling Of 01 Nos. 11 Kv Damaged Vcb With Strurcture ( If Any ) , 29 Nos. Single Support St / Rail Pole ( 13 / 11 / 9Mtr. ) With Complete Accessories And Ht Line Conductor From Work Site To Store Center, Mathura With Safe Loading And Unloading.