Carrying Out Various Works On Semi Turn Key Basis For System Augmentation, Strengthening Of Infrastructure In The Area Of Ee, Eudd Iii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura- 1 Cartage Of Following Material From Store Centre, Mathura To Work Site. 2 Stp 13 Mtr. Long ( Sp-70 ) Bottom Portion Galvanized 3 Stp 11 Mtr. Long ( Sp-55 ) Bottom Portion Galvanized 4 Clamp With Nut & Bolts 5 11 Kv D / O Fuse Set 6 33 Kv Pin Insulator With Pin 7 11 Kv Pin Insulator With Pin 8 33 Kv Disc Insulator 9 33 Kv Disc Fitting 10 11 Kv Disc Insulator With Fitting 11 Acsr Ins. Weasel Conductor 12 Acsr Dog Conductor 13 Stay Complate With Accessories 14 11 / 0.4 Kv, 100 Kva T / F 15 11 / 0.4 Kv, 250 Kva T / F 16 11 / 0.4 Kv, 400 Kva T / F 17 11 / 0.4 Kv, 630 Kva T / F 18 Lt Xlpe Cable 3.5X70 Sqmm. 19 Lt 3.5X70 Sqmm. S.T. Jointing Kit 20 Lt Xlpe Cable 3.5X150 Sqmm. 21 Lt 3.5X150 Sqmm. S.T. Jointing Kit 22 Lt Xlpe Cable 3.5X240 Sqmm. 23 Lt 3.5X240 Sqmm.S.T. Jointing Kit 24 Lt Xlpe Cable 1X1000 Sqmm. 25 Cable J / Kit S.T. For 33 Kv 3X300 Sqmm. 26 11 Kv Xlpe Cable 3X70 Sqmm. 27 Cable Jointing Kit Outdoor For 3X70sqmm. 28 Cable Jointing Kit S.T. For 3X120 Sqmm. 29 11 Kv Xlpe Cable 3X185 Sqmm. 30 Cable Jointing Kit Outdoor For 3X185 Sqmm. 31 Cable Jointing Kit S.T. For 3X185 Sqmm. 32 11 Kv Xlpe Cable 3X300 Sqmm. 33 Cable Jointing Kit Outdoor For 3X300sqmm. 34 Cable Jointing Kit Indoor For 3X300sqmm. 35 11 Kv V Type Cross Arm 36 Holding Clamp For Cross Arm 37 33 Kv Vcb 1250 Amp. 1250 Mva 38 33 Kv Ct, 400 / 200 / 1-1-A 39 Bus Isolator 800A, 33 Kv 40 33 Kv Control Panel For Single T / F 41 11 Kv Vcb, I / C Ctr 600 / 300 / 5A, 350 Mva 42 11 Kv Vcb, O / C Ctr 200 / 100 / 5A, 350 Mva 43 11 Kv Bus Coupler With Adopter Panel 44 Brass Glands For 3.5X70 Sq.Mm. Xlpe Cable 45 Brass Glands For 3.5X240 Sq.Mm. Xlpe Cable 46 Vaccume Interrupter Suitable For Different Make 11 Kv Vcb Panel 47 Cartage Of Above Material Like Various Size 33 Kv, 11 Kv Cable, Dog / Weasel Conductor, Jointing Kit, Vaccume Interrupter, Distribution Transformers, St / Pcc Pole, Insulator, Control Panel, Pin Insulator, Bus Isolator, Brass Glands, Channel, Clamps Etc. From Store Center, Mathura To Work Site And Dismentled Material From Site To Dvvnl Store. 48 Digging Of Pit & Erection Of New Single Support St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 49 Digging Of Pit & Erection Of New Double Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 50 Digging Of Pit & Erection Of New Tri Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 51 Concreting Of Pole As Per Approved Drawing & Technical Sepicifition 52 Providing & Fixing Of Stone Pad 53 Painting Of Pole With 1 Coat Of Red Oxide & 2 Coat Of Al. Paint 54 Fixing Of Ms Top Channel 55 Fixing Of Ms Dropper Channel 56 Providing & Fixing Of Ms T-Off Channel 57 Providing & Fixing Of Holding Clamp For Stp / Pcc With Nut & Bolts 58 Fixing Of Clamp With Nut & Bolts 59 Providing & Fixing Of Pp Clamp 60 Providing & Fixing Of Clamp For T-Off Channel 61 Fixingof 11 Kv D / O Fuse Set 62 Fixing Of 11 Kv Pin Insulator With Pin 63 Fixing Of 33 Kv Pin Insulator With Pin 64 Fixing Of 11 Kv Disc Insulator With Fitting 65 Fixing Of 33 Kv Disc Insulator 66 Fixing Of 33 Kv Disc Fitting 67 Laying Of Acsr Ins. Weasel Conductor 68 Erection, Laying, Testing & Commissioning Of Acsr Dog Conductor 69 Fixing Of Stay Complete With Grouting 70 Earthing Of Pole, Body & Neutral Earhing Of T / F By Earth Rod 71 Installation & Fixing Of Bus Coupler Along With Provding Accessories & Complete Installation Of 11 Kv Bus Coupler 1250 Amp. Copper Flat With Nut & Bolt Others Acc. For Connection 02 Different I / C 72 Erection, Testing & Commissioning11 / 0.4 Kv, 100 Kva T / F 73 Erection, Testing & Commissioning 11 / 0.4 Kv, 250 Kva T / F 74 Erection, Testing & Commissioning 11 / 0.4 Kv, 400 Kva T / F 75 Erection, Testing & Commissioning Of 11 / 0.4 Kv, 630 Kva T / F With All Accessories At Mobile Trolly. 76 Maintenance Of Repairing Old Trolly With All Material Like Tyre, Rim & Repairing Of Damage Part Painting And Fitting ( All Mterial Provided By Contractor ) 77 Laying Of 11 Kv Xlpe Cable 3X300 Sqmm. 78 Laying Of Lt Xlpe Cable 1X1000 Sqmm. 79 Providing & Fixing Of Barbed Wire 80 Providing & Fixing Of Ms Nut, Bolt And WasherS 81 Providing & Fixing Of Danger Board With Clamp 82 Providing & Fixing Of Guarding Angle 83 Providing & Fixing Of I Bolt 12X15 Mm. 84 Providing & Fixing Of Binding Wire 85 Providing & Fixing Of G.I. Wire 6 Swg 86 Providing & Fixing Of G.I. Wire 10 Swg 87 11 Kv Ms Angle 65X65x6x2700 Mm. Bracing Set With 04 No. Clamp 88 Digging Of Trenchbymaking Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of Cables Of Lt Line Size 3.5X70 Sq Mm. Xlpe By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 89 Digging Of Trenchbymaking Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of Cables Of Lt Line Size 3.5X150 Sq Mm. Xlpe By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 90 Digging Of Trenchbymaking Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of Cables Of Lt Line Size 3.5X240 Sq Mm. Xlpe By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 91 Laying Of 11 Kv Xlpe Cable 3X70 Sqmm. 92 Digging Of Trenchbymaking Pits / Open Trench Method / Hdd Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of Cables Of 11 Kv Size 3X185 Sq Mm. Xlpe By Manual Drill ( By Making Moles ) / Hdd Method / Open Trench Including All Material Like Brick & Sand And Back Filling And Restoring The Road To Make As Original. 93 Supply For 140 Mm Od Pn-4 Pe-80 Grade Uv Stabilized Hdpe Pipe As Per Is: 4984 94 Digging Of Trench By Open Trench / Hdd Method And Laying Of Hdpe Pipe And Laying Of 11 Kv 3X185 Sq.Mm. Cable Inside Hdpe Pipe. 95 Fixing & Filling Of Of Straight Through Cable Jointing Kit Suitable For 33 Kv 3X300 Sqmm. Xlpe Cable 96 Fixing & Filling Of Of O / D. Type Cable Jointing Kit Suitable For 11 Kv 3X300 Sqmm. Xlpe Cable 97 Fixing & Filling Of Of I / D. Type Cable Jointing Kit Suitable For 11 Kv 3X300 Sqmm. Xlpe Cable 98 Fixing & Filling Of Of O / D. Type Cable Jointing Kit Suitable For 11 Kv 3X185 Sqmm. Xlpe Cable 99 Fixing & Filling Of Of Straight Through Cable Jointing Kit Suitable For 11 Kv 3X185 Sqmm. Xlpe Cable 100 Fixing & Filling Of Of Straight Through Cable Jointing Kit Suitable For 11 Kv 3X120 Sqmm. Xlpe Cable 101 Fixing & Filling Of Of I / D. Type Cable Jointing Kit Suitable For 11 Kv 3X70 Sqmm. Xlpe Cable 102 Fixing & Filling Of Of Lt Cable Staight Through Suitable For 3.5X240 Sqmm. Xlpe Cable 103 Fixing & Filling Of Of Lt Cable Staight Through Suitable For 3.5X150 Sqmm. Xlpe Cable 104 Fixing & Filling Of Of Lt Cable Staight Through Suitable For 3.5X70 Sqmm. Xlpe Cable 105 Providing & Fixing Of G.I. Pipe 106 Providing & Fixing Of G.I. Pipe Clamp 107 Fixing Of 11 Kv V Type Cross Arm 108 Providing & Fixing F Bracket 109 Fixing Of Holding Clamp For Cross Arm 110 Erection Of 33 Kv Bus Isolator 800A 111 Erection Of 33 Kv Control Panel For Single Transformer 112 Erection Of Brass Glands For 3.5X70 Sq.Mm. Xlpe Cable 113 Erection Of Brass Glands For 3.5X240 Sq.Mm. Xlpe Cable 114 Supply & Erection Of Control Cable 4X2.5 Sq.Mm. 115 Complete Gel Earthingof 11 / 0.4 Kv 250 / 400 Distribution Transformer By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1.Earth Pipe Material – Mild Steel, Galvanised.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm.4-Wall Thickness Of Main Electrode :- 2.6Mm.5-Wall Thickness Of Auxiliary Ist Whole:- 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 116 Supply & Erection With Structure Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubicle Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 400 Kva ( Type A-2 ) ( Incomer - 1 Set Of 800 Amp.Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 6 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 5No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle 117 Supply & Erection With Stucture Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar ( Type B-2 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having :1 No Incomer 250Amp. Tp Mccb And 5 No.Out-Going 100 Amp. Tp Mccb Spreader & Extended Handle. 118 Supply Erection With Structure Of Lockable Distribution Box Along Withbar Lock Of Size 450X450mm Including Suitable Foundation With Bus Baramp. 140Tpn To Feed Up To 10 Houses ( Type C ) . Panel To Be Made Of 2Mm. Crca Sheet 119 L / C For Fabrication, Erection And Painting With Synthetic Enamel Bus Green Paint Of T / F Fencing Jali With One Side Gate, Welded Fabricated Wiremess 10 Swg With Size 35X4 Mm M.S. Flat X-Bracing Of Frame Size 10X8 Feet. ( 4 No. ) Including Cost Of M.S. Angle 40X40x5 Mm M.S. Flat 35X5 Mm And Nut & Bolt With Washer. All Material Will Be Provided By Contractor. ( 1 No. ) 120 L / C Forconstruction Of Dist. T / F Plinth Size 1.2X1.2X1.2 Cubic Mtr. With Solid Brick Work 75 Mm Thick C.C. In Ratio 1:4:8 With Cement, Coarse Sand And Brick Ballast And Smooth Finshing. All Material Will Be Provided By Contractor. ( 1 No. ) 121 L / C For Fabrication, Erection And Painting With Synthetic Enamel Bus Green Paint Of T / F Fencing Jali With One Side Gate, Welded Fabricated Wiremess 10 Swg With Size 35X4 Mm M.S. Flat X-Bracing Of Frame Size 10X8 Feet. ( 4 No. ) Including Cost Of M.S. Angle 40X40x5 Mm M.S. Flat 35X5 Mm And Nut & Bolt With Washer. All Material Will Be Provided By Contractor. ( 1 No. ) 122 Providing & Fixing Of Alluminium Lug 150 Sqmm. 123 Providing & Fixing Of Alluminium Lug 400 Sqmm. 124 Providing & Fixing Of Alluminium Lug 1000 Sqmm. 125 Erection, Testing & Commissioning Of 33 Kv Vcb, O / C Ctr 1250A, 1250 Mva 126 Erection, Testing & Commissioning Of 11 Kv Vcb, I / C Ctr 600 / 300 / 5A, 350 Mva 127 Erection, Testing & Commissioning Of 11 Kv Vcb, O / C Ctr 200 / 100 / 5A, 350 Mva 128 Erection, Fixing Of Vaccume Interrupter Suitable For Different Make 11 Kv Vcb Panel 129 Dismentling Of Old & Used 11 / 0.4 Kv 250 Kva T / F With Complete Accessories 130 Dismentling Of Old & Damage St Pole And Associated Accessories 131 Dismentling Of Old & Damage Acsr Weasel Conductor With Scrap 132 Dismentling Of Old And Damage A / B / C Type Panel With Complete Accessories 133 Dismentling Of Old And Damage 33Kv Vcb, 11Kv Vcb, 33 Kv Ct With Complete Accessories 134 Proper Road Restoration Kaccha / Pakka ( If Required ) Rates Shall Be Acceptable, If Not Given Above For The Same Work.