| 1 | Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 2/3/4 core cable upto 16 Sq.mm |
| 2 | Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 3.5/4 core cable 25Sq.mm to 120 Sq.mm |
| 3 | SUPPLYING & laying of 4Sq.mm 2 core CopperCable Unarmouned |
| 4 | SUPPLYING 4Sq.mm 3 core Copper Cable Unarmouned |
| 5 | Dismantling of H beam pole in meter |
| 6 | Dismantling of PCC pole in meter |
| 7 | Dismantling of R.S joist pole in meter |
| 8 | Relocation (One place to another place) ofH beam pole in meter |
| 9 | Relocation (One place to another place) ofPCC pole in meter |
| 10 | Relocation (One place to another place) ofR.S joist pole in meter |
| 11 | Arm/angle/channel/plate welding on pole |
| 12 | Supply and erection of ring or required shape for mini mast for required no. of flood light |
| 13 | Supply and installation of tubelar pole in meter |
| 14 | Supply and installation of armin meter of pole for street light |
| 15 | M20foundation for any type of pole with required Nut bolt |
| 16 | Earthing of G.I. Plate with charcoal etc complete |
| 17 | earthing of copper plate with charcoal etc complete |
| 18 | chemical earthing complete |
| 19 | supply and laying of G.I. Wire conductor earth electrod4.0 mm (8.S.W.G.) dia G.I. Wire complete |
| 20 | supply and laying of G.I. Strip 25x6 mm |
| 21 | Laying rigid PVC single socket end, non-metallic pipe ISI Marked (IS-4985-2000) class 5 for protection of under ground cable/or for water pump delivery side, for water supply complete with necessary clamp coupler,band, tee, Elbow etc. in an approved manner excluding cost of excavation etc laying of different size of pipe. |
| 22 | Erection of pole direct in a ground with required material,RCC/PCC |
| 23 | Iron oxide paint colour with labour |
| 24 | All oxide paint colour with labour |
| 25 | Other paint colour as required with color (yellow, Black,Blue etc.) |
| 26 | Any wattage of LED flood lightinstallation labour |
| 27 | Any wattage of LED Street lightinstallation labour |
| 28 | Base plate Welding on pole as a required size and shape |
| 29 | Fan repairingincluding of relavant IS Standard required material |
| 30 | Timer repairing including material (Contractor, switch, MCB etc.) |
| 31 | cooler repairing including material |
| 32 | Main switch repairing including material |
| 33 | short point wiring in existing on surface including wire and other material |
| 34 | Medium point wiring in existing on surface including wire and other material |
| 35 | Long point wiring in existing on surface including wire and other material |
| 36 | short point wiring in existing in conduit including wire and other material |
| 37 | Medium point wiring in existing in conduit including wire and other material |
| 38 | Long point wiring in existing in conduit including wire and other material |
| 39 | power wiring as per inexisting 2 x 4 sq.mm on surface with cable and casing & caping |
| 40 | power wiring as per inexisting 2 x 6 sq.mm on surface cable and casing & caping |
| 41 | power wiring as per inexisting 2 x 8 sq.mm on surface cable and casing & caping |
| 42 | power wiring as per inexisting 3 x 4 sq.mm on surface cable and casing & caping |
| 43 | power wiring as per inexisting 3 x 6 sq.mm on surface cable and casing & caping |
| 44 | power wiring as per inexisting 3 x 8 sq.mm on surface cable and casing & caping |
| 45 | power wiring as per inexisting 2 x 4 sq.mmin conduit |
| 46 | power wiring as per inexisting 2 x 6 sq.mm in conduit |
| 47 | power wiring as per inexisting 2 x 8 sq.mmin conduit |
| 48 | power wiring as per inexisting 3 x 4 sq.mmin conduit |
| 49 | power wiring as per inexisting 3 x 6 sq.mm in conduit |
| 50 | power wiring as per inexisting 3 x 8 sq.mmin conduit |
| 51 | Circuit wiring inexisting2 x 2.5 sq mm on surface |
| 52 | Circuit wiring inexisting 2 x 1.5 sq mm on surface |
| 53 | Circuit wiring inexisting 2x 1.00 sq mm on surface |
| 54 | Circuit wiring inexisting 3 x 2.5 sq mm on surface |
| 55 | Circuit wiring inexisting 3x 1.5 sq mm on surface |
| 56 | Circuit wiring inexisting 3 x 1.00 sq mm on surface |
| 57 | Circuit wiring inexisting 2 x 2.5 sq mmin conduit |
| 58 | Circuit wiring inexisting 2 x 1.5 sq mmin conduit |
| 59 | Circuit wiring inexisting 2x 1.00 sq mmin conduit |
| 60 | Circuit wiring inexisting 3 x 2.5 sq mmin conduit |
| 61 | Circuit wiring inexisting 3x 1.5 sq mmin conduit |
| 62 | Circuit wiring inexisting 3 x 1.00 sq mm in conduit |
| 63 | control pannel repairing including material |
| 64 | Water Cooler repairingincluding material |
| 65 | Ro repairingincluding material |
| 66 | All type of Speaker repairing including material |
| 67 | All type of mixerrepairing including material |
| 68 | All type of Audio Amplifier including material |
| 69 | LED Light Repairing including Glass, PCB, Driver and other required material30 w |
| 70 | LED Light Repairing including Glass, PCB, Driver and other required material 48 w |
| 71 | LED Light Repairing including Glass, PCB, Driver and other required material60 w |
| 72 | LED Light Repairing including Glass, PCB, Driver and other required material 90 w |
| 73 | LED Light Repairing including Glass, PCB, Driver and other required material120 w |
| 74 | LED Light Repairing including Glass, PCB, Driver and other material required 150 w |
| 75 | LED Light Repairing including Glass, PCB, Driver and other required material200 w |
| 76 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 30 w |
| 77 | LED Flood Light Repairing including Glass, PCB, Driver and other required material48 w |
| 78 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 60 w |
| 79 | LED Flood Light Repairing including Glass, PCB, Driver and other required material90 w |
| 80 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 120 w |
| 81 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 150 w |
| 82 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 200 w |
| 83 | LED Flood Light Repairing including Glass, PCB, Driver and other required material250 w |
| 84 | LED Flood Light Repairing including Glass, PCB, Driver and other required material 300 w |
| 85 | LED Flood Light Repairing including Glass, PCB, Driver and other required material400 w |
| 86 | Supply and Installation LED Street light in watt |
| 87 | Supply and Installation LED Flood light in watt |
| 88 | MCB Box 4 way (4+12) |
| 89 | MCB Box 4 way (8+12) |
| 90 | MCB Box 6 way (8+18) |
| 91 | MCB Box 8 way (8+24) |
| 92 | MCB Box 12 way (8+36) |
| 93 | Same boardswithch and socket - 6 Amp. |
| 94 | Same boardswithch and socket - 16 Amp. |
| 95 | Modular Box/plate 2 module with required size and shape with switch and socket required |
| 96 | Modular Box/plate 4 module with required size and shape with switch and socket required |
| 97 | Modular Box/plate 6 module with required size and shape with switch and socket required |
| 98 | Modular Box/plate 8 module with required size and shape with switch and socket required |
| 99 | Modular Box/plate 10 module with required size and shape with switch and socket required |
| 100 | Modular Box/plate 12 module with required size and shape with switch and socket required |
| 101 | Modular Box/plate 18 module with required size and shape with switch and socket required |
| 102 | Modular Box/plate 24 module with required size and shape with switch and socket required |
| 103 | D.G. Setservicing 125 KVA |
| 104 | D.G. Setservicing 15 KVA |