Supply Of Outdoor Electrical Panels For Lt Power Supply Distribution At Indian Institute Of Information Technology Guwahati , Design, Manufacture And Supply Of Cubicle Type, Double Door Panel Fabricated Out Of 2Mm Thick Crca Sheet Steel, Floor Mounted Totally Enclosed Switch Board Suitable For Use Of 415 Volts, 3 Phase, 50Hz Ac Supply System And To Withstand A Short Circuit Level Of 50Ka, Having Front And Back Side Operation Facilities. Complete With Aluminium Bus-Bar And All Accessories Including Supply And Fixing Of Following Incoming And Outgoing Switchgears.And Shall Be Dust And Rain Proofip65 Standard Suitable For Out Doorinstallation On Pedestal With The Following Facilities A) 3 Nos. Incoming Breaker On / Off / Trip Indicationlamp With Sp Mcb B) Fireand Corrosion Resistantcoating Applied In Two Coats With Necessary Primer The Sheet Steel Shall Undergo Minimum 7 Tank Treatment Followed By Finishing Powder Coating Of Min 60 Micron Thickness. C) Fire Retardant Dmc / Smc Fittings For Opening Aroundbus-Bars Near The Sectional Barrier. D)Facilities For Direct Termination With 400 Sqmm 3&1/2C Armoured Aluminium U/G Cable -2 Nos For Incoming And 2 Nos. For Outgoing Feeders In Lilo System.(Separate Aluminium Bus Bars Are Requiredtoprovide For Cable Termination Facility ). E) Shall Have High Mechanical Strength F) Door Interlocking Facility. G) Shall Have Fire Barrier. The Panel Shall Be Made As Per Relevant Si / Iec 61439 And Relevant Test Certificate Shall Be Furnished. Extended Rotary Handles For Mccbs And Other Accessories, All In Compartmentalised, Cubical Construction Complete In All Respects As Per Approved Drawing And Design Including Internal Wiring, Labels, Ferrules, Cable Termination Gland Plates, Earth Terminals, Painting Etc. Conforming To Specification , Outdoor Feeder Pillar No. 4(To Be Written On Door Of The Panel) Incoming: 3P 800 A 50 Ka Ics= 100% Icufixed Version Acbwith Microprocessor Based, . Electronicrelease Havingcurrent Adjustable Facility With Built In S/C, O/C Ande/F Protection, And Spreader Terminal - 1 Nos. (Make ; Legrend Dmx Sp 2500 Orequivalent L&T Or Semans As Approved). 1000 A Tpn Al. Bus Bar With Coloured Heat Shrinkable Pvc Sleeve-1 Set Outgoings: 320A 3P Mccb, 36 Ka (With Thermal Magnetic Protection E For S/C,O/C,& E/F )- 2Nos. 200 A 3P Mccb, 25 Ka - 2Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) – 2 Nos. Instruments: Digital Voltmeter (0-500 V) Indication Lamp Ryb With Mcb Protection Etc. As Req. 3 Nos. Incoming Breaker On / Off / Trip Indicationlamp With Sp Mcb Bus Bar Connection Facility Shall Be Provided To Connect 400 Sqmm 3&1/2C Armoured Aluminium U/G Cable - 3 Nos For Incoming And 2 Nos. Foroutgoing Feeders In Lilo System. , Outdoor Feeder Pillar No. 5(To Be Written On The Door Of The Panel) Incoming: 3P 800 A 50 Ka Ics= 100% Icu Fixed Version Acbwith Microprocessor Based, . Electronicrelease Havingcurrent Adjustable Facility With Built In S/C, O/C Ande/F Protection, And Spreader Terminal - 1 Nos. (Make ; Legrend Dmx Sp 2500 Orequivalent L&T Or Semans As Approved). 1000 A Tpn Al. Bus Bar With Coloured Heat Shrinkable Pvc Sleeve-1 Set Outgoings: 320 A 3P Mccb, 36 Ka - 1 Nos. (With Thermal Magnetic Protectionfor S/C,O/C,& E/F ) 200 A 3P Mccb, 25Ka - 2Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) – 40 A 3P Mccb, 16 Ka - 3Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) 40 A 4P Mcb, 16 Ka - 1Nos. – 40Adp Mcb, 16 Ka - 3Nos.- Instruments: Digital Volt Meter ( 0-500 V) Indication Lamp Ryb With Mcb Protection Etc. As Req. 3 Nos. Incoming Breaker On / Off / Trip Indicationlamp With Sp Mcb Bus Bar Connection Facility Shall Be Provided To Connect 400 Sqmm 3&1/2C Armoured Aluminium U/G Cable -2 Nos For Incoming And 2 Nos. Foroutgoing Feeders In Lilo System. , Outdoor Feeder Pillar No.6 (To Be Written On The Door Of The Panel) Incoming: 3P 800 A 50 Ka Ics= 100% Icufixed Version Acbwith Microprocessor Based, . Electronicrelease Havingcurrent Adjustable Facility With Built In S/C, O/C Ande/F Protection, And Spreader Terminal - 1 Nos. (Make ; Legrend Dmx Sp 2500 Orequivalent L&T Or Semans As Approved). 1000 A Tpn Al. Bus Bar With Coloured Heat Shrinkable Pvc Sleeve-1 Set Outgoings: 200A 3P Mccb, 36 Ka - 1 Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) -Indoor Stadium) 63A 4P Mccb, 25 Ka - 1Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) - 1 40 A 3P Mccb, 25 Ka - 7Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) - 4 Nos.. 40 A 4P Mcb, 16 Ka - 1Nos. – 40Adp Mcb, 16 Ka - 3Nos.- Instruments: Digital Volt Meter ( 0-500 V) Indication Lamp Ryb With Mcb Protection Etc. As Req. 3 Nos. Incoming Breaker On / Off / Trip Indicationlamp With Sp Mcb Bus Bar Connection Facility Shall Be Provided To Connect 400 Sqmm 3&1/2C Armoured Aluminium U/G Cable -2 Nos For Incoming And 2 Nos. Foroutgoing Feeders In Lilo System. , Outdoor Feeder Pillar No. 7(To Be Written On Door Of The Panel) Incoming: 3P 800 A 50 Ka Ics= 100% Icufixed Version Acbwith Microprocessor Based, . Electronicrelease Havingcurrent Adjustable Facility With Built In S/C, O/C Ande/F Protection, And Spreader Terminal - 1 Nos. (Make ; Legrend Dmx Sp 2500 Orequivalent L&T Or Semans As Approved). 1000 A Tpn Al. Bus Bar With Coloured Heat Shrinkable Pvc Sleeve-1 Set Outgoings: 320A 3P Mccb, 36 Ka -1 Nos. (With Thermal Magnetic Protection For S/C,O/C,& E/F ) – 200A 3P Mccb, 36 Ka - 3Nos. (Withthermal Magnetic Protection For S/C,O/C,& E/F ) –- 2 40 A 4P Mcb, 16 Ka - 1Nos. - Spare Instruments: Digital Volt Meter ( 0-500 V) Indication Lamp Ryb With Mcb Protection Etc. As Req. 3 Nos. Incoming Breaker On / Off / Trip Indicationlamp With Sp Mcb Bus Bar Connection Facility Shall Be Provided To Connect 400 Sqmm 3&1/2C Armoured Aluminium U/G Cable -2 Nos For Incomming And 2 Nos. For Outgoing Feeders In Lilo System.