}

Tender For Carrying Out Various Works On Semi Turn Key Basis For System Augmentation,. Strengthening In The Area Of Ee, Eudd I, Mathura Under The Jurisdiction Of Se, Eudc, Mathura, mathura-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited has published Tender For Carrying Out Various Works On Semi Turn Key Basis For System Augmentation,. Strengthening In The Area Of Ee, Eudd I, Mathura Under The Jurisdiction Of Se, Eudc, Mathura. Submission Date for this Tender is 21-10-2023. Electrical Maintenance Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39914166
Corrigendum : Tender For Carrying Out Various Works On Semi Turn Key Basis For System Augmentation,. Strengthening In The Area Of Ee, Eudd I, Mathura Under The Jurisdiction Of Se, Eudc, Mathura
Open Tender
Indian
Uttar Pradesh
Mathura
21-10-2023

Tender Details

Carrying Out Various Works On Semi Turn Key Basis For System Augmentation, . Strengthening In The Area Of Ee, Eudd I, Mathura Under The Jurisdiction Of Se, Eudc, Mathura- 1 Cartage Of Following Material From Store Centre, Mathura To Work Site. 2 St Pole ( 11 Mtr. Long ) ( Bottom Portion Galvanized ) 3 St Pole Pole ( 13 Mtr. Long ) ( Bottom Portion Galvanized ) 4 630 Kva T / F 5 250 Kva T / F. 6 100 Kva T / F. 7 Lt Aerial Bunch Conductor. 8 Lt Xlpe / Pvc Cable 1Cx630 Sq.Mm. 9 Lt Xlpe / Pvc Cable 1Cx400 Sq.Mm. 10 Lt Xlpe Cable Of Size 3.5X400 Sq. Mm. 11 Lt Xlpe Cable Of Size 3.5X240 Sq. Mm. 12 Lt Xlpe Cable Of Size 3.5X150 Sq. Mm. 13 Lt Xlpe Cable Of Size 3.5X70 Sq. Mm. 14 33 Kv Xlpe Cable 3X300 Sq.Mm. 15 11 Kv Xlpe Cable 3X70 Sq.Mm. 16 11 Kv Xlpe Cable 3X185 Sq.Mm. 17 11 Kv Xlpe Cable 3X300 Sq.Mm. 18 33 Kv Vcb 800 A, 750 Mva 19 33 Kv Control Panel For Single T / F 20 33 Kv Control Panel For Double T / F 21 33 Kv 3X300 Sq.Mm. Outdoor Type Cable Jointing Kit 22 11 Kv 3X70 Sq.Mm. Outdoor Type Cable Jointing Kit 23 Lt H / S Jointing Kit 3.5X240 Straight Through 24 Lt H / S Jointing Kit 3.5X150 Straight Through 25 Lt H / S Jointing Kit 3.5X70 Straight Through 26 11 Kv Fuse Set 27 11 Kv Tpmo 28 11 Kv Bus Coupler 29 Acsr Dog / Weasel / Ins. Weasel Conductor 30 Other Line Material Such As Cross Arm, Ms Bracing Set, Ms Top Channel, Bottom Channel, Tee-Channel With Clamp , Clamps, Pin Insulator, Disc Insulator Nut & Bolts, Earth Rod, Earth Wire, V Type X Arm, F Bracket, Guarding Wire, Etc. 31 Cartage Of Above Material From Store Center, Mathura To Work Site ( Cartage Rates Are Acceptable For Only Those Materials, Which Are To Be Carriage From Store Center, Mathura To Work Site ) 32 Grouting Of St Pole With Cement, Sand, Concrete, ( Cc Will Be Of Cement, Coarse Sand & Brick Balleast Grouting Will Be Done With The Help Of Wooden / Steel Formers In A Block Of Size 900Mm X 450Mm X 1 / 3 Of The Full Of The Support In The Cc 1:4:8 As Per Relevant Drawing Including Back Filling & Proper Ramming. 33 Digging Of Pit & Erection Of New Single Support St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 34 Digging Of Pit & Erection Of New Four Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 35 Digging Of Pit & Erection Of New Tri Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 36 Digging Of Pit & Erection Of New Double Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 37 Provinding & Fixing Of 24 Volt Battery With Battery Charges 38 Installing / Fixing Of Delta Earthing For I / C Vcb 39 Earthing Of St / Pcc Pole / Body Earthing Of T / F. By M.S Earth Rod. 40 Providing & Fixing Of Ms Nut, Bolt And WasherS 41 Providing & Painting Of St Pole. 42 Digging Of Pit & Erection Of Stay Rod With Grouting Cement Sand And Brick Ballast Including Nuzzling, Binding Complete. ( Stay Insulator Providing By Contractor ) 43 Installation Of 33 Kv Vcb 800 A, 750 Mva 44 Installation Of Control Pannel For Single T / F 45 Installation Of Control Pannel For Double T / F 46 Supply And Laying Of Control Cable 4X2.5 Sq.Mm. 47 Supply And Laying Of Control Cable 2X2.5 Sq.Mm. 48 Plinth & Foundation Of 33 Kv Vcb 49 Pipe In Pipe Gel Earthing For 33 Kv Vcb & Control Panel 50 Sagging Of 33 / 11Kv / Lt Line On Dog / Weasel Conductor On Erected Poles. 51 Providing & Sagging Of 33 Kv Line On Panther Conductor On Erected Poles 52 Laying Of Ab Conductor For Lt Line On Erected Poles. 53 Laying Of Lt Pvc Cable 1Cx630 Sq.Mm. 54 Laying Of Lt Pvc Cable 1Cx400 Sq.Mm. 55 Laying Of U / G. Lt Xlpe Cable Of Size 3.5X400 Sq. Mm. With Complete Job 56 Laying Of U / G. Complete Work Of Lt Xlpe Cable Of Size 3.5X240 Sq. Mm.With Complete Job 57 Laying Of U / G. Complete Work Of Lt Xlpe Cable Of Size 3.5X150 Sq. Mm.With Complete Job 58 Laying Of U / G. Complete Work Of Lt Xlpe Cable Of Size 3.5X70 Sq. Mm.With Complete Job 59 Guarding Of 33 / 11Kv Line. ( Including G.I. Wire And Other Related Items ) 60 Providing & Fixing Of Guarding Angle For 33 / 11 Kv Line 61 Providing & Fixing Of I Bolt For Guarding 62 Providing & Fixing Of Aluminium Biding Wire For Guarding 63 Providing & Fixing Of Clamp For Guarding Angle For 11 Kv Line 64 Providing & Fixing Of Earth Wire Clamp 65 Providing & Fixing Of Danger Board 66 Providing & Fixing Of Barbed Wire 67 Providing & Fixing Of Stone Pad 68 Providing & Fixing Of P.G. Clamp 69 Fixing Of 33 / 11 Kv V Type Steel Cross Arm 70 Fixing Of 11 Kv Pin Insulator With Pin 71 Fixing Of 33 Kv Pin Insulator With Pin 72 Fixing Of Disc Insulator 45 Kn & 70 Kn ( T&C / B&S ) 73 Fixing Of Disc Fitting 45 Kn & 70 Kn ( T&C / B&S ) 74 Providing & Fixing Of 33 Kv / 11 Kv F Bracket 75 Providing & Fixing Of Packing Piece Clamp For 33 Kv / 11 Kv With Nut & Bolts 76 Providing & Fixing Of Aluminium Lug 150 / 240 / 400 / 630 77 Providing & Fixing Of St Pole Clamp 78 Providing & Connecting Earthing Strip 79 Fixing & Filling Of 33 Kv 3X300 Sq.Mm. Outdoor Type Cable Jointing Kit 80 Fixing & Filling Of 11 Kv 3X70 Sq.Mm. Outdoor Type Cable Jointing Kit 81 Fixing & Filling Of Lt H / S Jointing Kit 3.5X240 Straight Through 82 Fixing & Fixing Of Lt H / S Jointing Kit 3.5X150 Straight Through 83 Fixing & Fixing Of Lt H / S Jointing Kit 3.5X70 Straight Through 84 Installation Of 11 / 0.4 Kv, 630 Kva T / F Mobile Trolley 85 Trolley Structure For 630 Kva T / F With Vehicle Tyre, Rim, Coupling, Trolly Hook, Earthing, Painting And Related Accessories With Complete Job 86 Providing & Fixing / Installation Of A-2 Type Lt Panelsupply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shell Be Detachable Type Gland PlateelectricalcontrolpanelwithtpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes.The Jobincludesthe Disconnecting Anddismentling Of Existing B-1 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge.Incoming : 400 Ampmccb1 Noand Outgoing 250 Amp Mccb 03 Nos, 160 Amp 03 Nos. With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With C-9 Tank Process Powder Coated Other Conditions Also 87 Providing & Fixing / Installation Of A-3 Type Lt Panelsupply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith TpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. Incoming : 630Ampacb- 1 Noand Outgoing 250 Amp Mccb 5 Nos And 100 Amp Mccb 2 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With C-9 Tank Process Powder Coated.The Jobincludesthe Disconnecting Anddismentling Of Existing A-3 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge. 88 Providing & Fixing / Installation Of A-1 Type Lt Panelsupply &Erectionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S.Channel Base With Bottom And Top Cable Entries Shall Be Detachable Type Gland Plateelectricalcontrolpanelwithtpnacb ( 65 Ka, 4Pole Elect Draw Out , Micro Processer Release Icu=Icw=Ics 1Sec ) With Short Circuit Protectionand TpnmccbS ( Fourpole50kawith Thermalmagneticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc. Complete In All Respects. The Instrument Chamber Shallbeseparate And Incoming Section Connecting With Proper Horizontal / Vertical Busbar And Outgoing Section With Cable Alley Sectionandshall Metering With Digital Multifunction Meter With Inbuilt Selector Switches, Instrument Fuses, Red Yellow And Blue Phase Indicators In Incoming Section, Currenttransformeretc.The Boardshallhave Suitablecapacity Electrolyticaluminumbusbarsas Peris8623insulatedwithheatshrink Color Codesleeveand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Detachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. ( Incoming : 1250Ampacb1 Noand Outgoing 400 Amp Mccb 6 Nos And 250 Amp Mccb 2 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etc ) Theswitchboardshallbe Fabricated With Galvanized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With Seven Tank Process Powder Coated Switchgear.The Jobincludesthe Disconnecting Anddismantling Of Existing A-1 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sections, The Grounding Ofthe Panel Boardas Per Directionsofengineer-Incharge. 89 Providing & Fixing / Installation Of B-1 Type Lt Panelsupply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shell Be Detachable Type Gland PlateelectricalcontrolpanelwithtpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes.The Jobincludesthe Disconnecting Anddismentling Of Existing B-1 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge.Incoming : 400 Ampmccb1 Noand Outgoing 250 Amp Mccb 03 Nos, 160 Amp 03 Nos. With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With C-9 Tank Process Powder Coated Switchgear 90 Providing & Fixing / Installation Of B-2 Type Lt Panelsupply &Erracetionoffactory Fabricated&Wired Metalcladdustandverminprooffloormounting Double Door Type Outdoor Application, With M.S. Channel Base With Bottom And Top Cable Entreis Shall Be Detachable Type Gland Plateelectricalcontrolpanelwith TpnmccbS ( Fourpole50kawith Thermalmagnaticrelease With Adjustable Over Current And Short Circuit Protection, Ics=100% Icu, Suitable For 415 V Ac ) Switchesandinstrument Chamber Etc.Complete In All Respects. The Instrument Chamber Shallbeseparate And Incomming Section Connecting With Proper Horizental / Vertical Busbar And Outgoing Section Cable Alley Sectionandshall Metering With Digital Multifuncation Meter, With Inbuilt Selector Switches, Istrument Fuses, Red Yellow Band Blue Phase Indicators In In Comming Section, Currenttransormeretc.The Boardshallhave Suitablecapacity Electrolyticaluminiumbusbarsas Peris8623insulatedwithheatshrink Color Codesleevand Mounted On Non Hygroscopic Supports Such As Cmc / Dmc Support With Deteachable Side Covers And Shall Be Suitable For Extension On The Sides. The Switches Entryboxesshallbecompletewithsuitablecable End Boxes. Incoming : 200 Ampmccb1 Noand Outgoing 125 Amp Mccb 6 Nos With Extended Rotary Handel, Spreder Set , Phase Barrier Etctheswitchboardshallbe Fabicated With Gelvnized Primesheet With A Minimum Thickness Of 1.6 Mm / 2Mm. With C-9 Tank Process Powder.The Jobincludesthe Disconnecting Anddismentling Of Existing B-2 Type Distribution Panel Including Of Complete Replace Old Burn Cables Ends And Joint New Cable With Cable Jointers, Luges, Double Compression Glands, Etc New Cables Will Joint As Per Connected Sizes In Incoming And Outgoing Sectionsgrounting Ofthe Panel Boardas Per Directionsofengineer-Incharge. 91 Providing & Fixing / Installation Of C Type Lt Paneldisconeccting And Dismentlingof Existing C Panel And Supply, Installation Testing Commisioning Offactory Fabricated&Wired Metalcladdustandverminproof Double Door Typeoutdoor Application Stand Mounting, M.S. Channel Base Incliding Channel Stand With Bottom Cable Entreis The Panel Boardshall Havesuitablecapacity Electrolytic Alumininum Busbars Asper Is8623 Or Above Istulated With Heat Shrink Sleeving And Mounted On Nonhygroscopic Supports Such As Cmc / Bmc Support. Panel Shall Be Completewithsuitablecableendboxes, Double Compression Glands. Panel Comparment Having Special Provision For Internal Locking System For Stop The Electricity Theft The Panelboard Shall Be Fabricated With Gelvnized Prime Sheet With A Minimum Thickness Of 1.6Mm / 2Mm. With Seven Tank Process Powder Coated. Panel Haveing Proper Space For Connectingincomming And Outgoing Cable Terminations. 92 Providing & Laying Of Hdpe Pipe 160 Mm Od Pn-4 Pe-80 Grade Uv Stabilized Hdpe As Per Is: 4984 Of 6 Meter Length With Complete Work Of Cable Laying 93 Horizontal Drilling Underground Installation Piping Hdpe Pipe 160Mm Dia With Minimum Depth Of Pipe 1.2 Below Surface For Double Circuit Length Of Line 94 Laying Of 33 / 11 Kv Xlpe Cable In Double Pole Structure / Loop Etc. 95 Digging Of Trench By Excavation Of Earth 0.90 / 1.5 Mtr. Deep Put Brick On Both Side, Filling Of Sand & Brick On Cable & Earth Ramming And Dressing Properly With Complete Job Of Laying 33 / 11 Kv Xlpe Cable In Trench 96 Installation Of D.O. Fuse Set Of 11 Kv 97 Providing And Installation Of 11 Kv R.M.U. ( As Per Elclosed Technical Specification ) 98 Installation Of Tpmo Of 11 Kv 99 Concreting Of Pole ( St 13 Mtr. / 11 Mtr. ) Pcc Pole 100 Installation & Fixing Of Bus Coupler Along With Provding Accessories & Complete Installation Of 11 Kv Bus Coupler 1250 Amp. Copper Flat With Nut & Bolt Others Acc. For Connection 02 Different I / C 101 Removal Of Old Transformer ( 160 / 100 / 63 / 25 / 16 Kva ) With All Connected Accessories From Existing Double Pole. 102 The Construction Of New Plinth Of Size 5’X5’X4’ Aboveground Level And One Ft. Below The Ground Level For 400 / 250 Kva Transformer 103 Installation Of Following Transformer On Plinth / Double Pole With All Connecting Accessories Jumering Etc. Including Carriage Of Transformers From Store Centre, Mathura To Work Site. 104 250 Kva Transformer On Plinth 105 100 Kva Transformer On Double Pole Structure 106 Providing And Installation Of Tail Less Unit Complete With Structure 107 Construction Of M.S Angle Fencing Of Size ( 3M X3m X2m ) Around The Plinth Of 400 / 250 Kva Transformer And Gap Between The M.S Angle Should Not Be More Than 65Mm. 108 Complete Gel Earthingof 11 / 0.4 Kv 250 / 400 Distribution Transformer By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1.Earth Pipe Material – Mild Steel, Galvanised.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm.4-Wall Thickness Of Main Electrode :- 2.6Mm.5-Wall Thickness Of Auxiliary Ist Whole:- 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 109 Complete Job Of Road Restoration As Original 110 Dismantling Of Single Support St / Rail Pole ( 13 / 11 / 9Mtr. ) With Complete Accessories And Other Dismantled As Per Site Requirement And Cartage Of Material From Work Site To Store Center, Mathura. 111 Dismantling Of Ht Line And Cartage Of Material From Work Site To Store Centre, Mathura. 112 Dismantling Of Ht Line And Cartage Of Material From Work Site To Store Centre, Mathura.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-10-2023 CORRIGENDUM 3 Date 06-10-2023
2 06-10-2023 CORRIGENDUM 4 Date 09-10-2023
3 09-10-2023 CORRIGENDUM 5 Date 12-10-2023
4 12-10-2023 CORRIGENDUM 6 Date 16-10-2023
5 16-10-2023 CORRIGENDUM 7 Date 18-10-2023
6 18-10-2023 CORRIGENDUM 8 Date 21-10-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 86000.0 /-
Tender Value
INR 85.29 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail