Tender For Provision Of 400 Kva Trolly Mounted Transformer For Jak Li Rc Under Ge 970 Ews. ; 1 Supply, Installation, Commissioning & Testing Of Highly Energy Efficient, Outdoor Type Oil Immersed Naturally Cooled ( Onan ) Transformer Copper Wound Type Of Capacity 400 Kva As Per Latest Is Code, Conforming To Is-1180, Level-Ii With Off Load Tap Changer On Primary Side To Vary Secondary Voltage Within Limit ( + ) 5% To ( - ) 7.5% In Step To 2.5% Including Standard Fittings And First Filling To Transformer Oil As Per Is-335 Of 1980 With Cooling System. The Transformer Shall Be Provided With Cable Termination Box To Terminate Outdoor Type Termination Of Suitable Size On Ht Side 11 Kv & Lt Side 1100 Volts.Transformer Step Down Ratio 11000 Volts / 433 Volts, 3 Phase 4 Wire, Impedance As Per Oil Type, Onan Cooled, Suitable For Outdoor Installations And Double Wound Core Type With Cold Rolled Grain Oriented Silicon Shell Insulated Laminations And Clamped To Minimize Vibration And Noise. The Winding Shall Be Copper And Shall Be Designed For Full Load Current And With Stand The Thermal And Electro Magnetic Stresses Arising Due To The Through Fault Current Vector Group Shall Be Dyn-11 Including Supply Of All Standard Fittings & Fixtures And Comprising Of The Followings :- 2 ( A ) Ht Cable Termination Box. ( B ) Lt Cable Termination Box. ( C ) Rating And Diagram Plate. ( D ) Earthing Terminals. ( E ) Lifting Lugs. ( F ) Oil Level Indicator With Minimum Level Marking. ( G ) Thermometer Pocket. ( H ) Conventional Conservator With Oil Filling Hole With Cap And Drain Cum Sampling Valve. ( J ) Air Release Plug. ( K ) Silica Gel Breather. ( L ) Off Circuit Tap Changer With Locking Provision. ( M ) Bi-Directional Rollers. ( N ) Jacking Pads. ( O ) Radiators / Fins And All ( Epoxy Painted ) . ( P ) Danger Notice Board. 3 Supply, Installation & Testing Of Outdoor Type Lt Control Panel, Cpri Approved, Suitable For 440 Volts ( Three Phase 4 Wire System ) , Made Out Of 3.15Mm Thick Powder Coated Crca Sheet, Front & Back Side Openable Type And Front Side With Double Door, Fixed With Hinges And Knob Including Locking Arrangement, Dust, Weather & Vermin Proof, Cubicle Type Of Size Not Less Than 0.80 X 0.60 X 0.40 Mtr And Fixed With Angle Iron Leg Of Size 32X32x6mm Thick And 0.40 Mtr Long / High - 04 Nos And Welded The Same And Fixed On The Trolly Including High Tensile Nut, Bolts And Washers Or Welding Etc, Dully Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer Complete With And Including Copper Bus Bar Of Four Pole In Colour Code Of Capacity 1000 Amps, Fixed Over Epoxy Insulator With And Including One No 800 Amps Acb 4 Pole 50 Ka Of Microprocessor Based Thermal / Magnetic Controller Including Necessary Copper Spreader For Main Controlling Switchgear With Incoming And Outgoing Connection, Voltmeter 0-500 V - 01 No, Ammeter 0 To 800 Amps - 01 No, Indicating Lamp Ryb - 01 Set, Complete All As Specified And Directed By Engineer-In-Charge. 4 M&L For Fabrication Of Towing Type Transformer Trolley Suitable For 400 Kva Transformer Step Down, Outdoor Type 11 Kv / 433 V Of Capacity Complete Made Out Of Ms I Beam Of Size 250Mm X 125Mm X 6.9Mm ( 37.3 Kg / Mtr ) And Ms Sheet For Platform 6Mm Thick, Mounted On 4 Wheels Size Of 7.50 / Or 16 ( Including Wheel Drums, Bearings ) With Rims Mounted On 02 Nos Front And Rear Axle Wheel With Leaf Spring Clamps Cushioning Arrangement, Between Platform And 02 Nos Front And Rear Axles, Complete With Towing Arrangement With Tow Hook To Take Full Load Of Trolley And Transformer, Jalli ( Xpm ) Around Platform On Angle Iron Frame Of Size 40X40x5mm Opening Arrangement From Both Side With Locking Arrangement For Loading And Unloading Of Transformer Including Welding, Bending And Drilling Holes, Spray Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Over All Surface, Complete All As Specified And Directed By Engineer-In-Charge. 5 ( A ) Size Of The Transformer Trolley Platform Shall Be 4 Mtr X 2.5 Mtr And Sufficient Space All Around After Transformer Installation For Ventilattion / Maint Purpose As Recommended By Oem And Accomodate Ht / Lt Connecting Cables Loops On The Platform. ( B ) The Trolley Shall Be Provided With Steel Square Net Of Suitable Guage Fixed On Angle Iron In All Around The Trolley Body With Opening Arrangement As Protection. ( C ) Necessary Provision For Pvc Insulated Heavy Duty Copper Cable Multistranded Single Core 95 Sqmm With Cable Lugs To Connect The Earting As Cut To Required Length - 50 Mtrs.Notes :- ( I ) Any Other Works Not Mentioned In Item Above But Required For Smooth Functioning Of Trolley Shall Be Deemed To Be Included In The Rates Quoted By The Contractor. ( Ii ) The Technical Drawings And Details Of Schedule A Item Nos 1, 2 & 3 Shall Be Submitted For Approval By Ge Before Procurement / Fabrication From Oem Factory / Workshop. 6 Supply, Laying, Commissioning & Testing Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Aluminium Conductor, 11000 Volts Grade ( Earthed ) With Aluminium Conductor Of Size 120 Sqmm 3 Core Rolled And Kept In Rotable ( For Opening And Closing The Cable ) Steel Cable Drum With Rotating Handle Of Suitable Size For Mounting And Fixing On Transformer Trolley, Complete All As Specified And Directed. 7 M&L For Cable End Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories, Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 Sqmm 3 Core, Complete All As Specified And Directed. 8 M&L And Testing Of Xlpelt Cable, 1100 Volts Grade, Pvcinsulated, Heavy Duty, Armoured, Multistranded Aluminium Conductor Cable Of Size 240 Sqmm 3.5 Core, Including Glands And Aluminium Lugs And Jointed In Any Description, Complete All As Specified And Directed. 9 M&L For Manual Operated Cable Reeling Drum Made Out Of Ms Sheet, Fixed On Trolly, Suitable For Reeling Minimum 50 Rm Lt Side 240 Sqmm 3.5 Core Cable, Complete All As Specified And Directed.