Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART - I(A) Special repair toMain Adm block (Bldg No- P/CPWD/30)/Repair of buildings |
| 2 | Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead. |
| 3 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 Sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand). |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead nominal concrete 1:3:6 or richer mix in floor. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead for thickness of tiles 10 mm to 25 mm. |
| 6 | Providing and laying Non skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer - in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 8 | Providing and laying vitrified floor tiles in 600 x 600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 9 | Providing and laying Vitrified tiles of 600mm x 600mm sizes (thickness to be specified by manufacturer), with w of approved make, in all colours & shade, in skirting over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete |
| 10 | Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 11 | Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete. |
| 12 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 14 | Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in Old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete. |
| 15 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead nominal concrete 1:3:6 or richer mix in floor. |
| 16 | Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 17 | Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand). |
| 18 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 19 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 20 | Providing and laying APP modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 liter/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/liter and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. |
| 21 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 mlead of area 3 Sqm and below. |
| 22 | Providing and fixing aluminium work for door with extruded built up standard tubular sections and other sections of approved make, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with required EPDM rubber/neoprene gasket etc. Aluminium snap beading for glazing/ paneling, stainless steel screws etc all complete by powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 23 | Providing and fixing aluminium work for door with extruded built up standard tubular sections and other sections of approved make, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with required EPDM rubber/neoprene gasket etc. Aluminium snap beading for glazing/ paneling, stainless steel screws etc all complete by powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 24 | Providing and fixing 5.50mm thickness float glass panes in aluminium door shutters with EPDM rubber/ neoprene gasket etc complete . |
| 25 | Providing and fixing float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) in aluminium door shutters with EPDM rubber/ neoprene gasket etc complete . |
| 26 | Providing and fixingPowder coated minimum thickness 50 micron aluminium tubular handle bar handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screws etc complete. |
| 27 | Providing and fixing double action floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc complete with stainless steel cover plate minimum 1.25mm thickness. |
| 28 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors incl necessary cutting and making good etc. complete. |
| 29 | Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete. |
| 30 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 31 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 32 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type). |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 6 coarse sand). |
| 34 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) |
| 35 | Providing wood work in frames of wall paneling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc with Kiln seasoned and chemically treated hollock wood. |
| 36 | Providing and fixing 12 mm thick flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). |
| 37 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections consisting of main \"T\" runner with suitably spaced joints to get reqd length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, with GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop. |
| 38 | SCHEDULE ‘A’ PART - I(B) Special repair toMain Adm block (Bldg No- P/CPWD/30)/Repair of Plumbing and sanitary fittings |
| 39 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 40 | Providing and fixing 10 ltr capacity (white) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 41 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan |
| 42 | Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc. |
| 43 | Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc. |
| 44 | Providing and fixing 25 mm dia nominal bore G.I. Pipes complete with G.I. Fittings including trenching and refilling etc. |
| 45 | Providing and fixing of 15mm nominal bore CP bib cock of approved quality. |
| 46 | Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete. |
| 47 | Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 48 | Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long. |
| 49 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 50 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 51 | Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete. |
| 52 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia. |
| 53 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia. |
| 54 | Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks. |
| 55 | Providing and fixing of 15mm nominal bore CP angle cock of approved quality. |
| 56 | Providing and fixing of 15mm nominal bore connection pipe of approved quality. |
| 57 | Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality (screwed end) |
| 58 | SCHEDULE ‘A’ PART - I(C) Special repair toMain Adm block (Bldg No- P/CPWD/30)/(Internal Electrifications) |
| 59 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit incl dismantling as required (Group B). |
| 60 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 61 | Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 62 | Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 63 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 64 | Supply and fixing brass batten/ angle holder including connection etc. as required. |
| 65 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 66 | Supply and fixing 2 + 4 way, Single door (SP) and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 67 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp. |
| 68 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp. |
| 69 | Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 70 | Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 71 | Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 72 | Supplying and drawing 2x 6.00 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 73 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 74 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 75 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep. |
| 76 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 77 | Switch fuse disconnector unit TPN, 32 Amps, 415 volts. |
| 78 | Wiring for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required |
| 79 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 80 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 81 | SCHEDULE ‘A’ PART - II(A) Special repair to JCO Club (Bldg No. S/29)/Repair of Bldgs |
| 82 | Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead. |
| 83 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand). |
| 84 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead as per direction of E- In - C of nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 85 | Providing and laying vitrified floor tiles in sizes 600mm x 600mm(thickness to be specified by the manufacturer) with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 86 | Providing and laying Vitrified tiles in sizes 600 x 600mm (thickness to be specified by manufacturer), of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete |
| 87 | Marble stone flooring with 18 mm thick Udaipur green marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with. |
| 88 | Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 89 | Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete. |
| 90 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete. |
| 91 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 92 | Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete. |
| 93 | Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete. |
| 94 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work. |
| 95 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 96 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification |
| 97 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. |
| 98 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 m lead nominal concrete 1:3:6 or richer mix in floor. |
| 99 | Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 100 | Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand) |
| 101 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
| 102 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 103 | Dismantling cement asbestos sheets or other hard board in ceiling,including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 104 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead. |
| 105 | Providing and fixing 12.5mm thick square edge Gypsum tile of size 595x595mm, made of Gypsum plasterboard and fixed in true horizontal level , suspended on interlocking metal grid of hot dipped galvanized steel section, consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick ( minimum) sheet, spaced at 1200 mm centre to centre and cross \"T\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \"T\" at 600mm centre to centre to form a grid of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in grid including required cutting/making, opening for services etc complete. Main T runner to be suspended from ceiling using GI slotted cleats od size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4 mm GI adjustable wire etc all complete with white colour tiles. |
| 106 | Dismantling roofing of GS Sheet roofing,including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres. |
| 107 | Providing and fixing of PPGI profile Sheet of 0.50mm (+0.05%) total coated thickness with zinc coating 120 gm per sqm in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scrateches during transportation and should be supplied single length upto 12m or as desired by Engineer - In - Charge . The sheets should be fixed using self drilling/ self tapping screws of size 5.5x55mm with EPDM seal, complete to the existing truss and purlins etc complete. |
| 108 | Providing and fixing PPGI sheet ridges or hips of width (500- 600mm) overall width plainsheet of 0.50 mm (+0.05%) total thickness , zinc coating fixed 120grms per sqm as per IS :277 using self drilling or self tapping screws complete. |
| 109 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below. |
| 110 | Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides. |
| 111 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm. |
| 112 | Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete. |
| 113 | Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood. |
| 114 | Providing and fixing to existing door frames, 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. |
| 115 | Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 116 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
| 117 | Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm. |
| 118 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type). |
| 119 | SCHEDULE ‘A’ PART - II(B) Special repair to JCO Club (Bldg No. S/29)/Plumbing and Sanitary fittings |
| 120 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 121 | Providing and fixing 10 ltr capacity (white) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 122 | Providing and fixing white vitreous china pedestal type water closet (European type) with with ISI marked white solid plastic seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. |
| 123 | Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc. |
| 124 | Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc. |
| 125 | Providing and fixing 25 mm dia nominal bore G.I. Pipes complete with G.I. Fittings including trenching and refilling etc. |
| 126 | Providing and fixing of 15mm nominal bore CP bib cock of approved quality. |
| 127 | Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete. |
| 128 | Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 129 | Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long. |
| 130 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 131 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 132 | Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete.. |
| 133 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia. |
| 134 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia. |
| 135 | Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks. |
| 136 | Providing and fixing of 15mm nominal bore CP angle cock of approved quality. |
| 137 | Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality. |
| 138 | Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end). |
| 139 | SCHEDULE ‘A’ PART - II(C) Special repair to JCO Club (Bldg No. S/29)/Internal Electrification |
| 140 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) . |
| 141 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 142 | Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 143 | Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 144 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 145 | Supply and fixing brass batten/ angle holder including connection etc. as required. |
| 146 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
| 147 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 148 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp. |
| 149 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp. |
| 150 | Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 151 | Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 152 | Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 153 | Supplying and fixing Bell Push modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 154 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, completeas required. |
| 155 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 156 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep. |
| 157 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 158 | Switch fuse disconnector unit TPN, 62 Amps, 415 volts. |
| 159 | Wiring for for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required |
| 160 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 161 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 162 | SCHEDULE ‘A’ PART - III(A)Special repair and rewiring of internal electrification of Non residential buildings at Pallel. |
| 163 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 164 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 165 | Supplying and fixing 5/6 amps switch on the existing switch box/ cover including connections etc. as required. |
| 166 | Supplying and fixing 5/6 A socket outlet on the existing switch box/ cover including connections etc. as required. |
| 167 | Supplying and fixingstepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. |
| 168 | Supplying and fixing 15/16 A socket outlet on the existing switch box/ cover including connections etc. as required. |
| 169 | Installation of exhaust fan 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 170 | Supply and fixing of PVC batten / angle Holder including connection |
| 171 | Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 172 | Supplying and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 173 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, as required. |
| 174 | Installation, testing and commissioning of pre-wired, LED fitting / compact LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 175 | Supplying and fixing 5 amps to 32 amps single pole rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 176 | Supplying and fixing 40 A rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 177 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. Details of cost for one Set |
| 178 | Providing and fixing 630 A and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 179 | Providing and fixing 200 A and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 180 | Providing and fixing 100 A and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 181 | Supplying, installing on wall, testing and commissioning of 200 A capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 No aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439) |
| 182 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : of 70 sq. mm. |
| 183 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : of 90 Sqmm. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail