Tender For Rewiring, Wiring Work & Etc. In Rbipmt Hospital.-Rewiring, Wiring & Mainer Work At Various Block & Etc. In Rbipmt Hospital.; 1 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 2 122.2.126:Sitc Of Wall Mounted Fan 400Mm Sweep Rated Voltage 220-230 Ac Rated Frequency 50Hz Speed 1280-1350 Rpm With Desired Color 3 122.2.37:S / I / T / C Of Recess Mounting Crca Housing 36W Led Luminaire With Acrylic Cover Diffuser With Following Specifications Including Fixing On Existing Wall / Surface With Connections As Reqd. ( A ) Total System Wattage = 36 Watt + / - 5% ( B ) Luminus Efficacy >=95 Lumens / Watt. ( C ) Power Factor >=0.95 4 122.2.38:S / I / T / C Of Surface Mounting Crca Housing 36W Led Luminaire With Acrylic Cover Diffuser With Following Specifications Including Fixing On Existing Wall / Recess With Connections As Reqd. ( A ) Total System Wattage = 36 Watt + / - 5% ( B ) Luminous Efficacy >=95 Lumens / Watt. ( C ) Power Factor >=0.95 5 Od9286 / 2023-2024:Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32Amps 240 Volts C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 6 Od9287 / 2023-2024:Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 7 Od9288 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 8 Od9289 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 9 Od9290 / 2023-2024:Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way ( 4 + 18 ) , Double Door 10 Od9291 / 2023-2024:Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 4 Way ( 4 + 12 ) , Double Door 11 Od9292 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12 Way, Double Door 12 Od9293 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator8 Way, Double Door 13 Od9294 / 2023-2024:Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 14 Od9295 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 4 Sq. Mm 15 Od9296 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5 Sq. Mm 16 Od9297 / 2023-2024:Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group C 17 Od9298 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 18 Od9299 / 2023-2024:Wiring For Circuit / Sub Main Wiring Alongwith Earth Wirewith The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 19 Od9300 / 2023-2024:Wiring For Circuit / Sub Main Wiring Alongwith Earth Wirewith The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2x2.5 Sq.Mm+1X2.5 Sq.Mm Earth Wire 20 Od9301 / 2023-2024:Wiring For Light / Power Plug With 2X4 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required 21 Od9314 / 2023-2024:Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required 22 Od9315 / 2023-2024:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 23 Od9316 / 2023-2024:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 24 Od9317 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 25 Od9318 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 16 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 26 Od9332 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 27 Od9333 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 28 Od9334 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 29 Od9335 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 30 Od9336 / 2023-2024:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 31 Od9337 / 2023-2024:Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 32 Od9338 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base &Amp; Cover Plate For Modular Switches In Recess Etc As Required.12 Module ( 200Mmx150mm ) 33 Od9339 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module ( 125Mmx125mm ) 34 Od9340 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) 35 Od9341 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.4 Module ( 125Mmx75mm ) 36 Od9342 / 2023-2024:Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 37 Od9343 / 2023-2024:Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 38 Od9344 / 2023-2024:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.32 Mm 39 Od9345 / 2023-2024:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm