The Work For System Improvement / Strengthening Works In Municipal Area Under Uedd-V, Varanasi On Semi Turn-Key Basis In System Strengthening Scheme 2023-24- 1 The Work For Verious System Improvement / Strengthening Works In Municipal Area Under Uedd-V, Varanasi 2 Stay Clamp For St Pole With N&B 3 Lt. Clamp For Stp / Pcc With N&B 4 Lt Shackle Insulator 5 Loop / Stay Insulator 6 Ms X-Arm Clamp For Stp 9 / 11 Mtr 7 Eye Bolt 8 T / F Base Clamp With N&B 9 P.G. Clamp For Panther 10 Isolator Clamp For Panther 11 Cable Holding Clamp 12 Holding Clamp For Gi Pipe 13 Hdpe Pipe 110Mm 14 Gi Pipe 100Mm 15 M.S. Nut & Bolts Off Size 16 Dead End Clamp With Eye Hook 17 Suspension Clamp With Eye Hook 18 Clamp For Eye Hook With N&B 19 Lt Cable S / C 1X35 Sq Mm 20 Lt Distribution Box With Clamp And N&B 21 Lt Insulated Piercing Clamp For Enagiging D / B 22 Lt Bare Netural Connector ( P.G. Clamp ) 23 Allu Lug For 95 Sq.Mm 24 Allu. Lugs For 400 Sq Mm 25 Allu. Lugs For 630 Sq Mm 26 Allu. Lugs For 50 Sq Mm 27 Allu. Lugs For 1000 Sq Mm 28 Cost Of Copper Z Clamp For 250 Kva T / F With Nut Bolt & Washer 29 Cost Of Copper Z Clamp For 400 Kva T / F With Nut Bolt & Washer 30 Cost Of Copper Z Clamp For 630 Kva T / F With Nut Bolt & Washer 31 4X2.5 Mm Sq Copper Control Cable 32 2X2.5 Mm Sq Copper Control Cable 33 6X2.5 Mm Sq Copper Control Cable 34 Supply And Errection Of Lt Mccb 800 Amp. 35 Supply And Errection Of Lt Mccb 400 Amp. 36 Supply And Errection Of Lt Mccb 250 Amp. 37 Supply And Errection Of Lt Mccb 100 Amp. 38 Supply And Errection Of Lt Distribution Paneel Type A-2 39 Supply And Errection Of Lt Feeder Piller 40 Supply And Errection Of Lt Service Piller 41 Replacement / Addition Of Lt Poles In Line 42 Carriage Of S.T. Pole 9 Mtr / Pcc Pole 8.5 Mtr Fromstore To Site With Loading & Unloading 43 Dismantling Of Old & Damaged Pole 9 / Pcc Pole 8.5 Meter Long After Dismentling Of Cond. & Accessories From Line And Its Proper Steking . 44 Erection Grouting & Plinthing Of New 9 / Pcc Pole 8.5Meter Long Including Fixing Of Accessories And Resagging & Stringing Of Old Conductor On Re-Errected Pole. 45 Fitting Of Earthing Rod 46 Carriage Of Damaged / Dismentilled Pole From Dumping Store To Raja Talab Store With Loading & Unloading 47 Grouting Of Stay, Nozelling & Fixing Of Stay Wire Etc. 48 Guarding Of Ht Lines 49 Labour Charge For Laying And Stringing Of Two Nos Gi Wire With Lacing And Binding 50 Fabrication And Fixing Of Fitting 51 Carriage Of Material From Store To Work Site Including Loading And Unloading. 52 A. Replacement / Addition Of Poles In H.T Line 33Kv Or 11Kv 53 Carriage Of S.T. Pole 11 Mtrfromstore To Site With Loading & Unloading 54 Dismantling Of Old & Damaged Pole 11 Meter Long After Dismentling Of Cond. & Accessories From Line And Its Proper Steking . 55 Erection Grouting & Plinthing Of New 11 Meter Long Including Fixing Of Accessories And Resagging & Stringing Of Old Conductor On Re-Errected Pole. 56 Fitting Of Earthing Rod 57 Carriage Of Damaged / Dismentilled Pole From Dumping Store To Raja Talab Store With Loading & Unloading 58 Grouting Of Stay, Nozelling & Fixing Of Stay Wire Etc. 59 Bifurcation Of 11 Kv Overloaded Feeders* 60 Loading Unloading & Carriage Ofconductor, Earth Rod, Stay Set, G.I. Wire, Angle, Channel Etcfrom Raja Talab Central Store To Site 61 Loading Unloading & Carriage Of Stp 11 Mtr Longfrom Raja Talab Central Store To Site 62 Loading Unloading & Carriage Of 11 Kv Cable, From Raja Talab Central Store To Site 63 Erection Grouting Of 11 Mtr D / P With Fitting Of All Accessories Including In Cost Of Grouting Material 64 Grouting & Nozzling Of Stay Including Cost Of Grouting Material. 65 Laying & Dressing Of U / G11 Kv 3X185 Sq Mm Xlpe Cabled / C After Digging Of Roadincluding In Cost Of Brick, Patiya & Sand And C.I. Pipe Required Of Road X-Ing As Per Norms 66 Laying & Dressing Of U / G11 Kv 3X185 Sq Mm Xlpe Cable Through Hdd Methode Required Of Road X-Ing As Per Norms 67 Laying, Testing & Commissioning Of 11 Kv 3X185sq Mm Xlpe Cable D / C ( 2X100mtr ) Inhdpe Pipe After Supply & Laying Of D / C Hdpe Pipe ( 2X50mtr ) Of 200 Mm Dai By Horrizontal Drilling Mathod With Drilling Machine The Pipe Shall Be Leid At The2.5 Mtr Deep Below Railway Track. Sp. Earthing Of D / P On Both Side As Per Norms .G.I.Pipe Of Size 4 Dia 3 Mtr Long, Suitable Clamp & Nut Bolts Fixing Of All Accessoriesandearthing Material Etc. 68 Documentation Charge For Railway X-Ing 69 Earthing Of Pole By Earthing Rod 70 Fitting Of Cable Marker With Cost Of Cable Marker 71 Jointing Of 11 Kv O / D H.S. J. Kit For 3X185 Sq Mm Xlpe Cable 72 Jointing Of 11 Kv S / T H.S. J. Kit For 3X185 Sq Mm Xlpe Cable 73 Hoisting Of 11 Kv 3X185 Sq Mm Cable On Double Pole Through G.I.Pipe Of Size 6 Dia, 3 Mtr Long Including Its Jumpring Complete 74 Painting Of Stp 11 Mtr & Fitting With 01 Coat Red Oxide & 02 Coat Allu. Paints After Prepartion Of Sulface Including Cost Of Material 75 Additional Lt Circuits* 76 Cartage Of Following Material From Raja Ka Talab Storeto Site Including Loading & Unloading 77 Cartage Of Abc Size ( 3X120+1X95+1X16 ) Sqmm And Other Material As Per Estimate 78 Cartage Of S T Pole 9 Meterlong From Storeto Site Including Loading & Unloading 79 Errection, Grouting & Plinthing Of Stp 9 Mtr Including Cost Of Grouting Material 80 Erection & Commissioning Of ( 3X120 ) And 3X95 Sq Mm Xlpe Abc With All Accessories Dead End Clamps, Suspension Clamps, Lt Cable S / C, Connector Such As Clamp For Pole And Eye Hook Etc 81 Grouting Of Stay It Nozelling Fixing Of Stay Wire Complete Including Cost Of Grauting Material 82 Fixing Of Dist. Boxes On Lt Pole Including All Clamps And Material For Mounting, Connection & Sealing 83 Connection Of Consumer Service Cable Hrough Distribution Boxes After Commissioning Of Abc Line. 84 Earthing Of Pole By Earth Rod 85 Painting Of Stp 11 Mtr & Fitting With One Coat Of Red-Oxide Post Man Colour & Two Coat Al. Paints Including Cost Of Materials 86 Increasing Capacity Of Distribution Transformers From 63 / 100 To 250 Kva 87 Loading Unloading & Carriage Of 250 Kva T / F From Raja Talab Central Store To Site 88 Loading Unloading & Carriage Of Other Material From Raja Talab Central Store To Site 89 Dismentaling Of Old 100 Kva T / F And Shuifting From Work Site To Store Including Loading And Unloadiung. 90 Errection & Mounting Of New 250 Kva T / F On Existing D / P And Making Connection And Jumpring By Laying Of Lt Cable 91 Sp. Earthing Of 250 Kva T / F Netural Or Body Sepertaly Chemical Pipe And Connection With G.I. Strip Off Size 30X5 Mm Including Cost Of Material 92 Increasing Capacity Of Distribution Transformers From 250 To 400 Kva 93 Loading Unloading & Carriage Of 400 Kva T / Fand Other Material From Raja Talab Central Store To Site 94 Dismentaling Of Old 250 Kva T / F And Shuifting From Work Site To Store Including Loading And Unloadiung. 95 Errection & Mounting Of New 400 Kva T / F On Existing D / P And Making Connection And Jumpring By Laying Of Lt Cable 96 Sp. Earthing Of 400 Kva T / F Netural Or Body Sepertaly Chemical Pipe And Connection With G.I. Strip Off Size 30X5 Mm Including Cost Of Material 97 Increasing Capacity Of Distribution Transformers From 400 / 630 To Add. 250Kva 98 Loading Unloading & Carriage Of 250 Kva T / F From Raja Talab Central Store To Site 99 Loading Unloading & Carriage Of 9 / 11 Mtr St Pole From Raja Talab Central Store To Site 100 Loading Unloading & Carriage Of Condusctor, Abc Size ( 3X120+1X95+1X16 ) Sq Mm , Ms Channel, Angle, Disc, Pin, Earthing & Decentralised Materials From Raja Talab Central Store To Site 101 Erection Of D.P Including Grouting And Plinthing Of Pole Fitting Fixing Of S / S Base Of M.S. Angle / Channel, Fixing Of All Accessories 102 Laying And Sagging Of Weasel For 11Kv Line 103 Errection & Mounting Of250 Kva T / F On D / P And Making Connection And Jumpring. 104 Erection & Commissioning Of ( 3X120+1X95+1X16 ) Sq Mm Xlpe Abc With All Accessories Dead End Clamps, Fixing Of Dist. Boxes Suspension Clamps, Such As Clamp For Pole And Eye Hook Etc. 105 Errection Of Earthing Rod 106 Fitting & Fixing Of Lt Bus Bar 107 Painting Of Stp 9 / 11 Mtr & Fitting With One Coat Of Red-Oxide Post Man Colour & Two Coat Al. Paints Including Cost Of Materials 108 Sp. Earthing Of 250 Kva T / F Netural & Body Sepertaly With Chemical Pipe And Connection With G.I. Strip Off Size 30X5 Mm Including Cost Of Material 109 Replacement Of Components In 33 / 11 Kv Ss 110 Loading Unloading & Carriage Of All Required Materials Includingct, Isolators, Crp, 33Kv Vcb & Decentralised Material Etc. Fromstore To Site 111 Erection, Connection, Fitting And Testing Of 33 Kv Isolator 112 Erection, Connection, Fitting And Testing Of 33 Kv Lightening Arresters 113 Erection, Connection, Fitting And Testing Of 33 Kv Ct 114 Erection, Connection, Fitting And Testing Of 33Kv Pt 115 Erection, Connection, Fitting And Testing Of 33 Kv Vcb 800A , 750Mva With Structure 116 Errection Of 24 Volt Battery And Charger Including All Connection 117 Laying Of Control Cable In Switch Yard And Making All Connections 118 Earthing Of All Equipment With Earth Strip 119 Earthing Of Distributiontransfomers ( Chemical Earthing ) 120 Sp. Type Earthing Of Distribution Transformer For Neutral Or Body Of Diffrent Capacity By Providing Ans Fixing Of Chemical Pipe And Connectiom With The Help Of Gi Strip 30X5 Mm Duly Galvanized Shall Be Used. Every Dt Shall Have To Such Earthing One Earthing For T / F Body And Second For Neutral Both These Points Shall Be Connected To Earth Through Gi Strip ( 30X5 Mm ) Separately. All Required Materials Shall Be Supplied By The Contractor. 121 Requirement Of Mobile Distribution Transformer With Trolley* 122 Providing And Fixing Of Movable Trolly For 630 Kva Distribution Transformer Complete In All Respect 123 Loading Unloading & Carriage Of 630 Kva T / F From Raja Talab Central Store To Site 124 Errection & Mounting Of 630 Kva T / F On New Trolly And Making Connection And Jumpring By Laying Of Lt Cable 125 Strengthening Of L.T Line 126 Loading Unloading & Carriage Of All Materialfrom Raja Talab Central Store To Dump Store Anddump Store To Site 127 Fabrication Of Lt Bus Bar And Fixing On Existing Dp Then Bus Bar With Acsr Dog Conductor 128 Fabrication Of Areal Fuse Unit And Fixing On Bus Bar Then Making All Lt Circuit Connection Complete 129 Errection Of Lt Distribution Piller, Feeder Piller And Service Piller Alog With Grouting And Connection 130 Earthing Of All Lt Pannel 131 Strengthening Of 33Kv U / G Line 132 Loading Unloading & Carriage Of 33 Kv Cable, From Raja Talab Central Store To Site 133 Laying & Dressing Of U / G 33 Kv 3X300 Sq Mm Xlpe Cable After Digging Of Roadincluding In Cost Of Brick, Patiya & Sand And C.I. Pipe Required Of Road X-Ing As Per Norms 134 Jointing Of 33 Kv O / D H.S. J. Kit For 3X300 Sq Mm Xlpe Cable 135 Hoisting Of 33 Kv 3X300 Sq Mm Cable On Double Pole Through G.I.Pipe Of Size 6 Dia, 3 Mtr Long Including Its Jumpring Complete 136 Inc. Capacity Of 33 / 11Kv S / S - 1 Nos 137 Loading Unloading & Carriage Of All Required Materials Includingct, Isolators, Structures, M.S. Channel, Angle, Crp, 11Kv Vcb, 33Kv Vcb & Decentralised Material Etc. From Raja Talab Central Store To Dump Store Anddump Store To Site 138 Grouting, Errection Of Following Structure And Fitting With Mounting Of Equipments. Complete In All Respect. 139 33 Kv Isolator 140 33 Kv Lightening Arresters 141 33 Kv Post Insulator 142 33 Kv Ct 143 Errection Of Plinth & Foundation Of Power T / F Plinth Including Cost Of Material 3.5X3.5X1.5 M As Per Standred. 144 Errection And Commissioning Of 10Mva Transformer On Plinth And Fixing Of All Accessories Along With Top Up Of Transformer Oil Complete In All Respect. 145 Plinth & Foundation Of 33 Kv Vcb / Pannel And Plinth Of Operation In S.Yard With Material 146 Laying And Connection Of Control Cable 4X2.5 Sq Mm, 2X2.5 Sq Mm & 6X2.5 Sq Mm From Switchyard To Control Pannel In Control Room Including Construction Of Trench And Providing Stone Cover With Materail 147 Laying Of 11 Kv Cable 3X300 Sq Mm Xlpe Cable With Brick, Stone & Sandincluding Hanging Of Cable. 148 Installation Of 11 Kv Switch Gear & Control Panel In Control Room Complete Work Including 149 Jointing Ofout Door / In Door 11 Kv 3X300 Xlpe Cable Box. Including Cost Of Jointing Box 150 Febrication & Fitting Fixing And Grouting Of Cable Stand With Grouting Material Etc 151 Earthing Of Indoor Equipment Including Cost Of Material Complete As Per Desing Prescribed By Resspo. 152 Earthing Of Outdoor Equipment Including Cost Of Material Complete As Per Desing Prescribed By Resspo. 153 Errection Of Rail Double Pole Along With Grouting And Plinthing For Bus Bar 154 Dismentling Of Existing Bus Bar And Shifting To New Double Pole After Fabrication And Fixing Of Fitting 155 Construction Pakka Cable Trench Of 2X2 With Cover For 11Kv Existing Cable Laying 156 Excavation Of Earth And Removal Of Existing Cable Then Laying Of Cable Into Pakka Cable Trench 157 Painting Of All Structure 01 Coat Red-Oxide & 2 Coat Paint Of Good Quality Including Material. 158 Leveling Of Switchyard & Laying Of Stone Blast In S-Yard As Per Norms 159 Construction Of Path Way & Lighting Of Switchyard Complete With Cost Of Material 160 Febracation & Fixing Of Fire Stand With 04 No Fire Bucket 161 Sp. Pipe Earthing Of Power T / F Nutral & Body Seperatewith 60 Deep G.I. Pipe 40 Mm Dia Including Material