Tender For Provision Of Otm Accommodation At Madhopur Under Ge Basoli ; 1 Lumpsum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I 2 Lumpsum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Ii 3 Lumpsum Price Worked Out By The Contractor For Plumbing Works As Listed In Schedule A Part-Iii 4 Lumpsum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Iv 5 Lumpsum Price Worked Out By The Contractor For Ac Referigeration Works As Listed In Schedule A Part-V 6 Lumpsum Price Worked Out By The Contractor Forsite Clearance Works As Listed In Schedule A Part-Vi 7 Lumpsum Price Worked Out By The Contractor For Road Path And Culvert Works As Listed In Schedule A Part-Vii 8 Lumpsum Price Worked Out By The Contractor For Widening Of Roads As Listed In Schedule A Part-Viii 9 Lumpsum Price Worked Out By The Contractor For Hard Standing Works As Listed In Schedule A Part-Ix 10 Lumpsum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule A Part-X 11 Lumpsum Price Worked Out By The Contractor For Lightning Protection Works As Listed In Schedule A Part-Xi 12 Lumpsum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Xii 13 Lumpsum Price Worked Out By The Contractor For Security Fencing And Compound Wall Works As Listed In Schedule A Part-Xiii 14 Lumpsum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Xiv 15 Lumpsum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-Xv 16 Lumpsum Price Worked Out By The Contractor For Dismantling And Demolition Works As Listed In Schedule A Part-Xvi 17 Ac Refergerationsupply And Fixing Electronic Voltage Stablizer For Automatic Operations, Single Phase, Naturally Air Cooler, Indoor Wall Mounted Type And Designed For Input Variation Between 170V To 270V With Output Voltage Stablized To 230V With Accuracy Of + / - 2.5% High / Low Voltage Protection With Time Delay Device, Voltmeter, Amps Meter And Of Capacity 2 Kva Complete All As Specified And As Directed. 18 Supply And Fixing Electronic Voltage Stablizer For Automatic Operations, Single Phase, Naturally Air Cooler, Indoor Wall Mounted Type And Designed For Input Variation Between 170V To 270V With Output Voltage Stablized To 230V With Accuracy Of + / - 2.5% High / Low Voltage Protection With Time Delay Device, Voltmeter, Amps Meter And Of Capacity 3 Kva Complete All As Specified And As Directed. 19 Supply, Installation, Testing And Commisioning Of Desert Cooler Electric Driven, 1 Single Phase Made Out Of 1Mm Thick Gi Sheet For Body With Water Tank Of Capacity 50 Litres And With Front Grill And Side Direction Shutters, Suitable For Minimum Air Delivery Of 4000 Cum Per Hour Approx 450Mm Sweep Fan Blade Size With Mild Steel Curved Blades Duly Painted With Synthetic Anti Corrosive Paint, Fitted To Body Including Prewired Electric 4 Speed Switch Control And One 6 Amps Piano Switch Water Immersed Pump Of Minimum Capacity 40 Watts 1300 Rpm Suitable For 230 Volts, 50 Hz Ac Supply And One 6 Amps Piano Switch, Fan Motor Of Minimum Capacity 105 Watts 1400 Rpm, 230 Volts, 50 Hz And Water Inlet Pipe With Brass Float Valve Of Size 15Mm And Outlet With Brass Drain Plug Of 20Mm. The Cooling Pad For Three Sides Shall Be Of Honey Comb Type. ( Note :- The Rate Shall Be Inclusive Of 3 Core 2.5 Sqmm Pvc Sheathed And Inculated Flexible Copper Cable Chord 2 Metre Long With 3 Pin 5 Amps Top Plug For Power Supply Complete All As Specified And Directed. 20 Road Path Providing And Applying 2.5 Mm Thick Road Marking Strips ( Retro Reflective ) Using Hot Thermoplastic Material By Fully / Semi Automatic Thermoplastic Paint Applicator Machine Fitted With Profile Shoe Heater, Driven By Experienced Operator On Road Surface Incl Cost Of Material, Labour, T&P, Cleaning The Road Surface Of All Dirt, Silt, Oil, Grease And Foreign Material Etc Complete All As Specified And As Directed. 21 Solar Rod Having 6 Led Of Colour Red / Yellow House In Plastic Body Cell Battery And Light Senscor Well Protected In Side Polycarbonated Sheet Device Protected With Power Coated Wire Mesh Cage System Mouted Over 47 Mm Dia Steel Tube Powder Coated Of Length 600 Mm Having Sheet Footed For Firm Grip To Ground. System Workable For 8 To 10 Hours Complete All As Specified And As Directed. 22 Stainless Steel Round Road Delineator Having Reflector Type Red / Yellow Colour In Plastic Body Protected In Side Polycarbonated Sheet, Protected With Powder Coated Wiremesh Cage System Mouted Complete All As Specified And As Directed. 23 Reflective Type Cat Ey Having Colour Red / Yellow To A Side, Casted Aluminium Allow Of Size 100X100x20mm With Built In Steam Of Suitable Length For Fixing With Protected In Side Complete All As Specified And As Directed. 24 S & F In Repair Stainless Steel Location Boards Type C Of Size 100 Cm X 76 Cm, Made Up Of Stainless Stell Tubes Framing Of Grade Fe 304, With Top Board At 9 Ft Above Ground With Letters, Figures Sand Base Of High Density Prismatic Retro Reflective Tape Of Superior Qualiy On Both Sides Of The Aluminium Composite Pannels ( Acp ) 3Mm Thick, Including Necessary Excavation For Potholes Of Size 30Cm X 30 Cmx 60 Cm Deep With Pcc 1:2:4 Type B- 2 Using 40Mm Graded Aggregate All As Specified And Directed. 25 Internal Water Supplyconstruction Of Valve Chambersize 60 X 60 X 60 Cm ( Internal Dimension ) With 100 Mm Thick Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregate ) Sub Base Of Floor, 50Mm Thick Pcc 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) In Floor, Finished Even And Smooth Without Using Extra Cement, One Brick Thick Wall In Cm 1:4 Using Old Size Sub Class B Bricks And Plastering Internally And Externally Upto 150Mm Below Gl 15 Mm Thick Withcementmortar ( 1:4 ) And Ms Sheet Cover Not Less Than 6 Mm Thick Withangle Iron Frame Size 40X40x6mm, Locking Arrengement And Painting With Two Coats Synthewtic Enamel Painting Over A Coat Of The Red Oxide Primer Including Excavation And Earth Work In Any Type Of Soil Complete All As Specified And Directed. 26 Drilling / Cutting Of Existing Ci Pipeline 150 Mm Dia For Making Branch Connection For 50 Mm / 25 Mm Gi Pipeline Including Placement Of Ms Clamp Made Of Flat Iron 50 X 6 Mm Bent To Shape Suitable For 150 Mm Dia Pipe Including Welded With Ms Socket 25 Mm Dia Etc Complete With Necessary Nut Bolt And Washers, Packing Sheet Required At Site Complete All As Directed. 27 Sewage Disposallldpe Septic Tank Designed To Carry Sewage And Sludge Water, Including Earth Work, Excavation, Returning Filling, Disposal Of Surplus Spoils To A Distance Not Exc 50 Meter From Starting Points, In Hard Rock, Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregates ) In Foundation, 200Mm Thick, Vent Shaft, Connections Etc.For 10 Users ( 1600 Litre Capacity ) Including All Fittings, Fixtures, Testing On Completion Approximate Dimensions. Dia 1440 Mm, Height 1550 Mm And Total Hrt 48 Hr Complete All As Specified And Directed. 28 Septic Tank ( Conventional ) 100 Users Rcc Septic Tank Designed To Carry Sewage And Sludge Water, Excavation In Any Type Of Soil Complete All As Specified & As Shown On Drawings. 29 Soakage Well, 2.40 M Dia And 3.00M Depth Below Inlet Pipe ( Depth Of Inlet Pipe 45Cm Below Normal Ground ) Including Excavation And Earth Work In Any Type Of Soil, Complete All As Specified And As Shown On Drawings. 30 Soakage Well, 3.00 M Dia And 4.50M Depth Below Inlet Pipe ( Depth Of Inlet Pipe 45Cm Below Normal Ground ) Including Excavation And Earth Work In Any Type Of Soil, Complete All As Specified And As Shown On Drawings. 31 Internal Electrificationm&L For Modular Point Wiring With 1.5 Sqmm ( Nominal Area ) Pvc Insulated Frls And Unsheathed Multistranded Coppeer Conductor Cable 1100 Volts Grade Drawn Through And Including Pvc Rigid Concealed Conduit Not Less Than 1.8 Mm Thick ( Isi Marked ) With All Accessories Including Suitable Modular Plate Andmodular Metallic Boxes Of Suitable Way Matching With Sorrounding Including 1.5 Sqmm Pvc Frls Insulated Unsheathed Copper To Common Earth Dolly, Complete All As Specified And Directed For The Following : Note:- Proper Colour Coding Is To Be Followed As Per Is Specification. ( A ) One Light Controlled By Modular Switch 6 Amp, Sp, One Way 240 Volts. 32 ( B ) One Ceiling / Exhaust Fan Point Controlled By One Modular Switch Sp, One Way, 6 Amp, 240 Volts. 33 ( C ) One Multi Pin Modular Socket 5 Amp Independent. 34 ( D ) One Multi Pin Modular Socket 5 Amp On Same Board 35 ( E ) One Bell / Buzzer Point Controlled By One Bell Modular Push. 36 All As Per Item No. 29 Here-In-Beofre But Using 2.5 Sqmm ( Nominal Area ) Multistranded Copper Conductor Cable & 2.5 Sqmm Size Pvc Insulated Frls And Unsheathed Copper Conductor Cable Frls For Earth Continuity ( Green Colour ) For One Modular 3 Pin Socket Outlet 15 Amp Multi Purpose Independent Point Controlled By 16 Amp, Modular Switch, Sp, One Way, 240 Volts For Socket, Complete All As Specified And Directed. 37 Supply And Fixing Box Mcb Protected Socket With Sheet Enclosure Single Pole 25 Amp With 3 Pin Plug Top Ac Connection From Socket Point Stablizer Complete All As Specified And As Directed. 38 Supply And Fixing Decorative Ultra Slim Polycarbonate Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficientled Luminaire, 32W 6500K With All Connected Accessories Internally Pre-Wired Connecting Lead Of 3 Core 1.5Sqmm Flexible Copper Wire From Ceiling Rose To Fitting Complete All As Specified And As Directed. 39 Supply And Fixing Decorative Ultra Slim Polycarbonate Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficientled Luminaire, 22W, 6500K With All Connected Accessories Internally Pre-Wired Connecting Lead Of 2 Core 1.5Sqmm Flexible Copper Wire From Ceiling Rose To Fitting Complete All As Specified And As Directed. 40 Supply And Fixing Of Trim Cosmo Surface Round Slim Surface Mounted Led Panel With Premium Diffuser To Ensure Glare Free & Even Light Distribution Led Luminaire, 12W 6000K With All Connected Accessories Internally Pre-Wired, Including 32W Led Lamp Connecting Lead Of 2 Core 1.5Sqmm Flexible Copper Wire From Ceiling Rose To Fitting Complete All As Specified And As Directed. 41 Supply And Fixing Of Recess Mounting Low Depth Aesthetically Designed Led 60 Cm X 60 Cm Flat Panels Glare Free Soft Illumination 36 Watt Cool White Connected Accessories Internally Pre-Wired, Including Led Light Connecting Lead Of 3 Core 1.5Sqmm Flexible Copper Wire From Ceiling Rose To Fitting Complete All As Specified And As Directed. 42 Supply & Fixingexhaust Fan 300 Mm Sweep Metal Body Complete Including Louvers And Connecting Up Including Making Provision Of Hole In Wall & Copper 3 Core Cable 1.5 Sqmm Multi Strandard From Ceiling Rose To Connector To Fan Complete All As Specified And As Directed. 43 Supply & Fixingceiling Fan Bldc 1200 Mm Sweep, White In Colour, 230 Volt , 5 Star Rating, 26 Watt With Down Rod, Canopy Cover Etc And Connecting With Copper Conductor3 Core Flexible .50 Sqmm From Ceiling Rose To Fan Complete All As Specified And As Directed. 44 S & F High Performance Ip66 Led Streetlight 20 Watt, Housing Made Of Die-Cast Aluminium, With Street Optic Lens, With All Accessories And Connecting Up With And Including Provision Of 3 Core Flexible Copper Wire Of Size 1.5Sqmm From Ceiling Rose, And 20W Led Light Etc. Drawn Through And Including 32Mm Bore Gi Light Grade Protecion Pipe Upto 1.0M Length With Suitable Fixing Accessories On Walls, Complete All As Specified And As Directed.Make: Wipro Cat Part No. Lr02-261-Xxx-57-Xx Or Its Equivalent Of Bajaj / Havells 45 M&Lforearthing Complete With G .L Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Burrieddirectlyinground ( Earth Pit Notless Than 2.25 M Deep Below Gl ) With Top Edge Of The Plate Not Less Than 1.5 Mbelow The Normal Groundlevelconnectedgalvanized Earth Lead Wire 4.0 Mm Bymeansofbolts, Nuts, Check Nuts And Washers Of Galvanised Ironorsteelincluding Necessaryexcavation& Earth Work In Any Type Of Soil, Removing Surplus Soil To A Distance Not Exc 50 M, Including Pcc Chamber In Pcc ( 1 : 2 : 4 ) , Type B1, Using ( 20 Mm Graded Stone Aggregate ) , Mild Steel Frame Madeout Of Angle Iron Of Size 40 Mm X 40 Mm X 6 Mm Thick Duly Painted With Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Zinc Chrome Primer Hinged With And Including 6 Mm Thick Cl Coverwith Handle , Watering Arrangement With Funnel Internally Secured With Wire Mesh With 20 Mm Dia Lightgrade Gi Pipe For Watering, 15 Mm Dia Mediumgrade, Gl Pipe For Earth Wire Protection With And Including Alternate Layer Of Charcoal Dust And Common Salt. Complete All As Shown In Electrical Plate No 3Connectedto Dbs All As Specified And Indicatedincluding Testingon Completion.Note : - ( I ) Gl Wire Upto 7.5M Will Bemeasured Andpaid Under This Item Only Extra Lead Will Be Measured And Paid Seperately Under Relative Link. 46 External Electric Supply M&L For Platform Of Size 3000X 2500 X 1500 Mm For Transformer Complete All Asspecified And As Shown On Drawing No Cepz / C-Td / 002 / 13. 47 M&L For Earthing Complete With Galvanised Steel Earth Plate Eletrode 600Mmx600mm And 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25Mtr Deep Below Normal Ground Level With Top Edges, Of The Plate Not Less Than 1.5M Below Normal Ground Level, Connected To The Galvanise Iron Earth Lead 32Mmx6mm ( Gi Strip ) Size, By Means Of Bolts, Nuts, Check Buts And Washers Of Galvanised Iron And 32Mmx6 Mm Earth Lead Protected By Provision Of Gi Medium Grade Pipe 40 Mm Bore Including Provision Of Aggregates With 40 Mm Thick Cover Of Rcc ( 1:2:4 ) , Reinforced With Xpm ( Weight Not Less Than 4 Kg Per Sqmm ) And Frame Of Angle Iron 40Mmx40mmx3mm And With 6 Mm Dia Ms Bar Handle Made To Shape, Gi Light Grade 20Mm Bore Pipe Of Suitable Length For Watering Perforated At Bottom Placed On Top Edged Of Earth Plate, Common Salt And Charcoal Filling, Funnel, Wire Mesh And Earth Work In Hard / Dense Soil, Returning Filling In Distance Not Exceeding 50 Mtr And Removal Of Surplas Soil To Plate No 3 Of Ssr 2009 Part-I And Connecting To Feeder Pillers And Transformer All As Specified Including Testing On Completion Complete All As Specified And Directed. 48 Supplying, Installation, Commissioning And Testing Apfc Panel Cubical Indoor Type, Factory Fabricated, Floor Mounted, Self Supported Compartment Metal Clad Made Out Of 3 Mm Thick Crca Sheet And Mounted On Channel Directly Coupled With Incommer Of Main Panel With Provision Of Extension Of Aluminium Bus Bar, Tp, Not Less Than 750 Amp Capacity With Necessary Nuts, Bolts And Washers, Jointing Materials With Proper Colour Coding, Providing Inside The Panel 125 Kvar Consisting Of 10 / 15 / 20 / 25 / 50 Kvar Capacitor Super Heavy Duty Dielectric Type Units In Tier Formation, Also Housed Inside The Panel An Integrated Cubical Type Automatic Switching On & Off Push Button, Indicators, Auto Manner Selector Switch For Each Bank, Heavy Duty Exhaust Fan For Heat Dissipation Installed Vertically At The Top Of The Panel Controlled By Providing Incomer Mccb 3 Pole Not Less Than 500 Amps, 50 Ka Etc 01 Nos Complete In All Respect Complete All As Specified And As Directed. Apfc Relay Epcos Br 6000 3 Phase Sensing With 12 Way MccbS ( Ics-100% Icu ) Not Less Than 2.5 Times Current Of Kvar Bank With Breaking Capacity 36 Ka And Not Less Than 2.5 Times Current Of Kvar Individual Bank Of Contactors On Delay Electronic Timer For Each Bank, Enclosure Shall Be Provided With Hinged & Lockable Doors To Achieve Dust & Vermin Proof, Front Operated Construction, Confirming To Ip 52, All Steel Surfaces Treated With Powder Coating After Proper Treatment With 7 Tank Process, Providing Top / Bottom Removable Gland Plates As Required, Bouble Compression Type Cable Glands, Earth Bus, Complete With And Including Aluminium Inter Connections, Wiring With Appropriate Size Of Copper Conductor Cable, Frls With Proper Identification Mark Incorporated With Suitable Rating Of Tpn Aluminium Bus Bar, Pvc Insulated With Colour Coding And Electrical Connection Etc Complete In All Respects As Specified And As Directed. 49 Supply, Laying, Jointing And Testing, Lt Cable 1100 Volts Grade Of Cross Sectional Area 240 Sqmmsingle Core As Per Is-7098 Part-I, Xlpe Insulated Aluminium Conductor Heavy Duty Served With An Inner Sheathing Pvc Tape, Galvanized Steel Strip Or Wire Armoured With An Overall Pvc Sheathing Laid In Trenches, Fixed Along The Poles Or Passed Through Gi Pipe Using Clamps Wherever Required Laid Under Floors, Road Etc Fixed Concealed In Walls Encased In Gi Pipe Connecting With Suitable Size Of Lugs And Aluminium Thimbles For Incoming And Outgoing Cablescomplete All As Specified And As Directed. ( Note : Ms Clamps With Nuts, Bolts Washer Etc Shall Be Measured And Paid Separately Under Relevant Items ) . 50 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed. ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.1200 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Supply And Fix Lt Switch Gear 40 Volts 3 Phase, 4 Wire 50 Cycles, Cubicle Or Truck Type Complete With Air Cricuit Breaker, Overload Protection, No Volt Release With Necessary CtS Meter And Cable Boxes Of Rating Upto 800 Amps. ( Incoming ) - 01 Nos ( Iii ) Mccbtp Rupturing Capacity 50 Ka 440 Volts, 3 Phasecap 320 Amps Ics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % ( Ics=100 % Icu ) -01 No ( Iv ) Mccbout Going Tp Rupturing Capacity 35 Ka 440 Volts, 3 Phasecap 200 Ampsics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % - 02 No ( V ) Mccbout Going Tp Rupturing Capacity 35 Ka 440 Volts, 3 Phasecap 250 Ampsics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % - 01 No ( Vi ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 100 Ampsics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % - 04 No 51 ( Vii ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 63 Ampsics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % - 02 No ( Viii ) Mccbout Going Sp Rupturing Capacity 18 Ka 240 Volts, Cap 40 Ampsics=100 Icu Thermal Magnetic Relase With Adjustable Setting 80 % To 100 % - 01 Nos ( Ix ) Ammeter With Selector Switch With Ct Ratio 800 / 5 Amps -01 No ( X ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No ( Xi ) Ledindicator Lamp Red / Yellow / Blue Colour - 03 Nos ( Xii ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 52 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed. ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.500 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Mccb Tp Rupturing Capacity 50 Ka 440 Volts, 3 Phasecap 320 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80 % To 100 % ( Incoming ) - 01 No ( Iii ) Mccbtp Rupturing Capacity 35 Ka 440 Volts, 3 Phasecap 250 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80 % To 100 % -01 No ( Iv ) Mccbout Going Tp Rupturing Capacity 35 Ka 440 Volts, 3 Phasecap 200 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80 % To 100 % - 02 No ( V ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 63 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100% -01 No ( Vi ) Ammeter With Selector Switch With Ct Ratio 500 / 5 Amps -01 No ( Vii ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No ( Viii ) Led Indicator Lamp Red / Yellow / Blue Colour - 03 Nos ( Ix ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 53 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed By Engr In Charge ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.100 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Mccb Fp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 63 Amps Ics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100%- 01 No ( Incoming ) ( Iii ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 32 Amps Ics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100% - 01 Nos ( Iv ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 20 Amps Ics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100% - 01 Nos ( V ) Mcbout Going Sp Rupturing Capacity 10 Ka 240 Volts, Cap 20 Amps - 03 Nos ( Vi ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No ( Vii ) Led Indicator Lamp Red / Yellow / Blue Colour - 03 Nos ( Viii ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 54 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed. ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.100 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Mccb Fp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 63 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100%- 01 No ( Incoming ) ( Iii ) Mcbout Going Sp Rupturing Capacity 10 Ka 240 Volts, Cap 20 Amps - 02 ( Iv ) Mccbout Going Tp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 40 Amps- 02 Nos ( V ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No ( Vi ) Led Indicator Lamp Red / Yellow / Blue Colour - 03 Nos ( Vii ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 55 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed. ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.100 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Mccb Fp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 40 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100%- 01 No ( Incoming ) ( Iii ) Mcbout Going Sp Rupturing Capacity 10 Ka 240 Volts, Cap 20 Amps - 04 Nos ( Iv ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No - 01 No ( V ) Led Indicator Lamp Red / Yellow / Blue Colour - 03 Nos ( Vi ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 56 Supply, Installation, Testing And Commissioning Oflt Feeder Pillar Made Out Of 3.15Mm Thick Crca Sheet And Mounted On Angle Iron Frame Of Size 65X65x6mm And 450Mm High ( Outdoor Type ) Weather / Dust Proof, Factory Made, Ip-54 With Openable Shutters On Both Sides Front And Rear Having Locking Arrangements, Totally Enclosed Weather Proof, Powder Coated Over A Coat Of Primer Suitable For 440V, 3 Phase, 4 Wire 50 C / S, Aluminium Bus Bar Of Of Suitable Size And Capacity, Ac Supply, Electrically Connected As Per Norms And Fitted Including Connecting Up All Out Going Mccb / Mcb With Suitable Size Of Alu Bus Bar Or With Stranded Copper Cable And Fixing On Suitable U Shaped Pcc Platform Comprising Of The Following Accessories Complete Allas Specified And Directed. ( I ) Aluminium Bus Bar With Proper Colour Code -04 Nos.150 Amp Cap Duly Fixed On Suitable Size Insulator, Nuts Bolts Etc Complete As Per Oem Recommendations. ( Ii ) Mccbfp Rupturing Capacity 25 Ka 440 Volts, 3 Phasecap 100 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100% - 01 No ( Incoming ) ( Iii ) Mcbout Going Sp Rupturing Capacity 18 Ka 240 Volts, Cap 20 Amps- 02 Nos ( Iv ) Mccbout Going Tp Rupturing Capacity 30 Ka 440 Volts, 3 Phasecap 63 Ampsics=100 Icu Thermal Magnetic Release With Adjustable Setting 80% To 100% - 02 Nos ( V ) Mccbout Going Tp Rupturing Capacity 30 Ka 440 Volts, 3 Phasecap 40 Amps 01 Nos ( Vi ) Mccb Fp Rupturing Capacity 30 Ka440 Volts, 3 Phase Cap 63 Amps, Ics=100% Icu, Thermal Magnetic Release With Adjustable Setting 80% To 100% ( Ics=100% Icu ) - 01 No ( Incoming ) ( Vii ) Mcbout Going Sp Rupturing Capacity 18 Ka 240 Volts, Cap 20 Amps- 10 Nos ( Viii ) Voltmeter With Selector Switch 0 To 500 Amps - 01 No ( Ix ) Led Indicator Lamp Red / Yellow / Blue Colour - 03 Nos ( X ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) Work Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Legs Of Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level . 57 Supply, Install, Testing And Commissioning Of Copper Wound Step Down Transformer, Outdoor Type, Oil Immersed, Naturally Cooled Onan, Rated Temperature Rise In Oil & Winding 45 / 50 Degree Centigrade Complete With Standard Fittings Of Capacity 400 Kva Ht 11 Kv, 3 Phase, Lt 433 V, 4 Wire, 50 Hz Of Vector Group Dyn-11 With Off Load Tap Changing Device On Ht Side To Vary Secondary Voltage From +5% To -10% In Steps Of 2.5% Including Cable Box On Lt And Ht Side, First Fill Of New Transformer Oil Having Dielectric Strength Not Less Than 60 Kv, Suitable Mounting Rails Of Appropriate Gauge And Other Standard Accessories All As Per Is:1180 ( Part-I ) : 2014 With Maximum Total Losses As Per Energy Efficiency Level 2 Of Is: 1180 ( Part-I ) : 2014 Complete All As Spcified And Directed.Note:- The Rate Quoted Deemed To Be Inclusive Of The Following:-A ) Accessories Such As Oil Level Gauge, Rating And Diagram Plate, Monogram Plate, Explosive Vent With Diaphragm, Thermometer Pocket With Thermometer, Top Filter Valve , Gun Metal Drain Valve At Bottom, Air Release Plug, Inspection Cover, Lifting Lugs / Hooks, Earthing Pads, Bi-Directional Plain Rollers, Oil Temperature Indicator, Winding Temperature Indicator, Buchhloz Relay With Valve, Marshalling Box, Silica Gel Breather & Other Standard Accessories All As Per Is:1180 ( Part-I ) : 2014 Etc. Any Other Items As Per Manufacturer Recommendations For Best Functioning Of Transformer If Required Are Deemed To Be Included In Quoted Rates. B ) The Platform Brick Masonary Shall Be Meausured And Paid Seperately Under Respective Items Of Boq / ScheduleA. C ) The Contractor Shall Make All Necessary Arrangements For Pre-Despatch Inspection At Manufacturer Site And For Pre-Commissioning Test By Representative Of Accpting Officerafter Installation Of Transformer. The Cost For The Same Is Deemed To Be Included In Quoted Rates.D ) The Contractor Shall Make All Necessary Arrnagements For Pre-Despatch Inspection At Manufacture Site Or In Case Of Covid-19 Restrictions Inspection Through Digital E-Testing To Be Arrnged And For The Pre Commissioning Test By Rep Of Accepting Officers After Installation Of Transformers. The Cost Of The Same Is Deemed To Be Included In The Quoted Rate. 58 Note: The Schedule Of Credit Has Been Attached In Tender In Pdf Format And Amount Of Credit Schedule I.E. Rs10, 54, 816.40 / - Shall Be Deducted From The Total Amount Of Boq To Arrive At The Contract Sum.