| 1 | Non SOR item |
| 2 | Supply installation testing and fixing of hanging /tension type clamp with 4 no connector |
| 3 | L.T.DB box |
| 4 | Pole painting |
| 5 | Energy meter |
| 6 | Supply and fixing clamp Patti G.I. pipe 32m.m. dia band type and nut bolt |
| 7 | Supply & fixing LED street light 90 watt with ISI make |
| 8 | Guarding per one span |
| 9 | Anti climbing device (barbed wire 3.5 kg) GS 2.5m.m. dia (12SWG) |
| 10 | Bracing set for 8 feet (2.45 mtr.) center DP angle of 65x65x6 m.m. |
| 11 | ACSR Dog conductor 0.10 Sq. inch (100 Sq.mm. AL. EQ.) |
| 12 | Jointing sleeves (alluminium) for dog conductor |
| 13 | Stone block / RCC base plate size 450x450x75 m.m. (3no. per stay & 1no. per pole for base padding as per drawing no discom/EZ/47 & 48) |
| 14 | Fencing of S/S land with barbed wire (as per drawing no. misc 22) |
| 15 | MS sign board, bay indication board & RYB phase indication board (as per tender drawing no. misc-7) |
| 16 | Approach road (WBM) with hume pipe culvert (as per drawing no. misc-11,12 & 13) |
| 17 | Approach road (RCC with ratio- 1:2:4) from main gate to power transformer foundation, size-(20x3) mtr (as per drawing attached ) fro black soil |
| 18 | Approach road, made by 60mm. thick factory made cement concrete paver block of m-30 grade, along the cable trenches upto various equipements in the yard |
| 19 | Approach road (RCC with ratio- 1:2:4) from main gate to power transformer foundation, size-(20x3) mtr (as per drawing attached ) fro hard soil |
| 20 | 1000 liter P/F sintex overhead tank & GI pipe (with length of 125 mtrs) fitting for water supply including providing water tap(17no.) near transformer neutral earthing |
| 21 | Providing & fixing perforated cable tray 300 mm. wide & 2 mm. thick fixed on 45x45x5 mm. M.S. angle stand grouted in C.C. 1:24 as per drawing misc-8) |
| 22 | Cost of retaining wall 1.5 m. high as per site requirement |
| 23 | Providing and fixing earth pit of brick massonery 0.6 x 0.6 m. inner size with flag stone cover for watering system for 18 no earth pits |
| 24 | Fire detection equipment |
| 25 | PTR 33/11 KV of TC 5000KVA (Loss 5.5 + 33KW) |
| 26 | 11 KV VCB, outdoor porcelain clad type with complete structure and accessories |
| 27 | 11 KV CT outdoor type 300-150 / 5 amp |
| 28 | 11 KV control & relay panel with numerical static relay for transformer protection (1T) |
| 29 | 33 KV VCB, outdoor porcelain clad type with complete structure and accessories |
| 30 | 33 KV CT outdoor type 300-150 / 5 amp |
| 31 | 33 KV control & relay panel with static relay for feeder protection |
| 32 | 33 KV CT outdoor type 200-100/ 5-5 amp |
| 33 | 33 KV control & relay panel with numerical static relay for transformenr protection |
| 34 | 11KV CT outdoor type 200-100 / 5 amp |
| 35 | 11 KV control & relay panel with numerical static relay for double feeder protection (2F) |
| 36 | Lead acid battery set 30 volt 100 AH |
| 37 | Battery charger 230 V AC input 10 amp. 30 v DC output solid state type |
| 38 | 33 KV, isolator 600 amp, W/O earth switch TP gabg operated |
| 39 | 11 KV, isolator 800 amp. W/O earth switch TP gabg operated |
| 40 | 33 KV LA polymer type gapless/ metal oxide substation type |
| 41 | 11 KV LA polymer type gaples /metal oxide 9 KV 10 KA substation type |
| 42 | 33 KV/110 V 3P4W CT/PT ratio 400-200 /5 amp. outdoor oil immersed type |
| 43 | 33 KV single phase PTS oil immersed |
| 44 | 11 KV single phase PTS oil immersed |
| 45 | HT trivector energy meter, DLM compliant category-A (for substation /feeder metering), 3 phase 4 wire, 110 volts, 5 AMP, accuracy class 0.5 S with GSM (GPRS compatible ) modem |
| 46 | Sheet metal meter box suitable for H.T. static travector meters with TTB |
| 47 | DC distribution board with MCB |
| 48 | AC distribution board with MCB |
| 49 | Copper control cable 8 core, 2.5 sq.mm. PVC unarmoured |
| 50 | Copper control cable 4 core, 2.5 sq.mm. PVC unarmoured |
| 51 | Copper control cable 2 core, 2.5 sq.mm. PVC unarmoured |
| 52 | T clamp aluminum for bus bar panther run panther TAP |
| 53 | Bimetallic clamps for power transformer 11KV side |
| 54 | LT trivector energy meter, DLMS compliant category-A (for substation/ feeder metering), 3 phase 4 wire, 440 volts, 5 amp, accuracy class 0.5S with GSM (GPRS compatible) modem with Box |
| 55 | AAAC panther conductor 0.20 Sq. inch (200 Sq.mm. AL.EQ.) |
| 56 | Bracing set for 4 feet (1.2 mtr.) centre DP angle of 65x65x6 |
| 57 | DC cross arms 8’ (2.4 meter ) centre to centre 100x50x6 mm. channel |
| 58 | Rail 2 meter 52 KG/meter |
| 59 | PVC cable 2 core armoured 2.5 Sq.mm. aluminium conductor |
| 60 | PVC cable 4 core armoured 16 Sq.mm. aluminium conductor |
| 61 | Earthing for each sub-station |
| 62 | Earthing of transformer neutral with Two numbers 50x5 mm. copper strips, 3 Nos. 11 KV pin insulators mounted on 100x50 mm. MS channel support and AL. pad clamp with two bimetallic strips for twin panther conductor and AAACConductor |
| 63 | Chemical earthing at 33/11 KV S/S hardsoil min11 nos. of chemrod |
| 64 | Paiting of structures |
| 65 | 11KV 1500 KVAR auto switch capacitor bask including associated EQ such as 11KV VCB, control panel, 11 KV outdoor current X’mer with adequated metering & protection class of service, bus & EQ |
| 66 | D.C. channel 2.70 mtr. Long |
| 67 | D.C. channel 4.8 mtr. Centre 100x50x6mm. |
| 68 | 11 KV composite polymer strain set with hard ware suitable for panther conductor |
| 69 | Terminal clamps |
| 70 | Concreting (1:3:6) of foundation of VCB @3.5 CMT |
| 71 | Sheet metal meter box suitable forH.T. static travector meters with TTB |
| 72 | 33 KV composite polymer strain set with hard ware suitable for panther conductor |
| 73 | T clamp aluminum for bus bar panther run panther TAP |
| 74 | Concerting (1:3:6) of structure & foundation @ 0.5 CMT. Per structure |
| 75 | Piercing connector type-1, 1P/3P (main 16-50Sq.mm. Tap-off 16-50Sq.mm.) |
| 76 | Piercing connector type-II, (main 16-50Sq.mm. Tap-off 16-50Sq.mm.) |
| 77 | Stone block / RCC base plate size 450x450x75mm (3 no per stay & 1 no per pole for base padding as per drawing no. disc M/EZ/47 & 48 |
| 78 | Spring loaded busbar system suitable for 1 incoming 6 outgoing 1 phase circuit |
| 79 | Spring loaded busbar system suitable for 1 incoming 3 outgoing 3 phase circuit |
| 80 | 100 kVA, bis certified, level-II transformer |
| 81 | 11 KV, LA polymer type gapless /metal oxide 9 KV 5 KA line type |
| 82 | Transformer mounting channel 100x50x6mm. |
| 83 | Transformer clamping set 50x50x6mm. angle 460mm long |
| 84 | Transformer belting set 50x50x6mm. angle with two cross fixing channel |
| 85 | XLPE LT 1 - core aluminium unarmoured 70 sq.mm. cable |
| 86 | XLPE LT 1 - core aluminium unarmoured 150 sq.mm. cable |
| 87 | PTR 33/11 KV of TC 3150 KVA (Loss 3+15 KW) |
| 88 | PTR foundation as per attached drawing |
| 89 | 11 KV AB switch three phase 600 amp TP gang operated |
| 90 | 33 KV AB switch 600 amp TP gang operated |