| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. |
| 5 | All kinds of soil |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 9 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) at all heights complete as per direction of Engineer-in-charge. |
| 11 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 12 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 13 | All works upto plinth level : |
| 14 | Concrete of M20 grade with minimum cementcontent of 270 kg /cum |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 19 | Foundations, footings, bases of columns, etc. for mass concrete |
| 20 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level. |
| 22 | Thermo-Mechanically Treated bars |
| 23 | Brick work withcommon burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 24 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 26 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 27 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size horizontal as well as vertical, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 28 | Granite stone slab of colour Z black, Cherry/Ruby red |
| 29 | Area of slab upto 0.50 sqm |
| 30 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 31 | Kiln seasoned and chemically treated hollock wood |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 33 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 34 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 35 | 35 mm thick shutters |
| 36 | With ISI marked stainless steel butt hinges of required size |
| 37 | Kiln seasoned and chemically treated hollock wood |
| 38 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. including dismantling of old Haps and staple /Sliding door bolt complete : |
| 39 | 300x16 mm |
| 40 | 250x16 mm |
| 41 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 42 | 300x10 mm |
| 43 | 200x10 mm |
| 44 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 45 | 125 mm |
| 46 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 47 | Twin rubber stopper |
| 48 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work/ frame of wire fabric, including cutting, hoisting, fixing in position (Including nut bolt/screws etc) and applying a priming coat of approved steel primer all complete. |
| 49 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses/ Gates etc. etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 50 | Hot finished welded type tubes |
| 51 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 52 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 53 | Double charge vitrified tile polished finish of size |
| 54 | Size of Tile 600 x 600 mm |
| 55 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 56 | 110 mm diameter |
| 57 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 58 | Bend 87.5° |
| 59 | 110 mm bend |
| 60 | Shoe (Plain) |
| 61 | 110 mm Shoe |
| 62 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 63 | 110 mm |
| 64 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 65 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 66 | Flashings/ Aprons.( Upto 600 mm) |
| 67 | 12 mm cement plaster of mix : |
| 68 | 1:6 (1 cement: 6 coarse sand) |
| 69 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 70 | 1:6 (1 cement: 6 coarse sand) |
| 71 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 72 | Two or more coats on new work |
| 73 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 74 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 75 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 76 | Two or more coats on new work |
| 77 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 78 | One or more coats on old work |
| 79 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specification. |
| 80 | One or more coats on old work |
| 81 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 82 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 83 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 84 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 85 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 86 | In cement mortar |
| 87 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 88 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 89 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 90 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 91 | 20 mm dia nominal bore |
| 92 | 40 mm dia nominal bore |
| 93 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 94 | 25 to 40 mm nominal bore |
| 95 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 96 | 20 mm nominal bore |
| 97 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 98 | 20 mm diameter pipe |
| 99 | 40 mm diameter pipe |
| 100 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
| 101 | 20 mm nominal bore |
| 102 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 103 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 104 | For fixed portion |
| 105 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 106 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 107 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 108 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 109 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 110 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 111 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 112 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m Kas per ASTM 518:1991,in true horizontal level suspended on inter-locking metal powder coatedT-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising ofmain-Trunners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-Tof size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 113 | With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 114 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with necessary screws complete. |
| 115 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 116 | Providing and applying white cement based putty of average thickness 0.5 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 117 | Providing & fixing Welded steel wire fabric mesh size 25x25 mm having wire dia 3 mm min. weight 3.08/sqm) to windows, clerestory windows & doors with M.S. Flat 15x3 mm with self drilling screws (min. 3 no. / mtr)/nuts & bolts at all levels complete. |
| 118 | Electrical |
| 119 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 120 | Group A |
| 121 | Group B |
| 122 | Group C |
| 123 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 124 | Group A |
| 125 | Group C |
| 126 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 127 | Group A |
| 128 | Group C |
| 129 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 130 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 131 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 132 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 133 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 134 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 135 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 136 | 3 x4 Sq.mm |
| 137 | 6 x4 Sq.mm |
| 138 | 3 X 1.5 Sq.mm |
| 139 | 3 X 6 Sq.mm |
| 140 | Providing and fixing Din-rail 35 mm on existing paneletc., as required. |
| 141 | Supplying and fixing ofG.I Saddles23 mm x 1.5 mm on following sizePVC / steel conduit/ cable / pipe etc as reqd. (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge)i) 50 mm |
| 142 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 143 | 20 MM |
| 144 | 25 MM |
| 145 | Supplying and fixing of following sizes ofPVC trunking with cover on surface(Wall,/Ceiling) having degree of protection as IP40, Ratedcurrent 500V, and making good the same as original complete etc. as required. |
| 146 | 100 x 50 |
| 147 | 32 X 16 |
| 148 | Supplying and fixing of following accessories for 100 X 50 mm^2 size of PVC trunking complete etc. as required. |
| 149 | Internal Angle |
| 150 | External Angle |
| 151 | End Cap |
| 152 | Flat Angle |
| 153 | Cover Joint |
| 154 | T- Joint |
| 155 | Supplying and fixing of following accessories for 32 X 16 mm^2 size of PVC trunking complete etc. as required. |
| 156 | Internal Angle |
| 157 | External Angle |
| 158 | End Cap |
| 159 | Flat Angle |
| 160 | Cover Joint |
| 161 | T- Joint |
| 162 | Supplying and fixing of following sizes module frame on existing trunking including arranging the cover making good the same as original complete etc. as required. |
| 163 | 1/2 Module Frame |
| 164 | 4 Module Frame |
| 165 | 6 Module Frame |
| 166 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 167 | 1 or 2 Module (75mmX75mm) |
| 168 | 6 Module (200mmX75mm) |
| 169 | 8 Module (125mmX125mm) |
| 170 | 12 Module (200mmX150mm) |
| 171 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 172 | 5/6 amp switch |
| 173 | 15/16 amp switch |
| 174 | 3 pin 5/6 A socket outlet |
| 175 | 6 pin 15/16 A socket outlet |
| 176 | Supplying and fixing two module stepped type electronic modular fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 177 | Supplying and fixing two module stepped type electronic piao fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 178 | Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. asrequired. |
| 179 | 5/6 amps switch |
| 180 | Supply & Fixing suitable size GI Box with modular plate and cover in front on surface or in reccess including provising and fixing 6 pin 5/6 and 15/16 amps moduler socket outlet and 15/16 amps moduler switch connection ect. as required. |
| 181 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 182 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 183 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.( For Geyser) |
| 184 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 185 | Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 186 | 300 mm |
| 187 | 380 mm |
| 188 | 450 mm |
| 189 | Providing and fixing 3 mm thick PVC/phenolic laminatedround sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required. |
| 190 | Providing and fixing 3 mm thick PVC / phenolic laminatedround sheet cover on the existing junction boxwith two screws, etc., as required. |
| 191 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 192 | Supplying and fixing suitable size GI box in recess, including providing and fixing of 3/4 Module LED Foot light /skirting light,including connection etc. as required. |
| 193 | Supplying and fixing two module Buzzer on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 194 | Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 195 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 196 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 197 | Supplying and fixingPRCD Plug top, 16 A 30 mA rating including connection etc. as required. |
| 198 | Supplying and fixing Plug top following rating including connection etc. as required. |
| 199 | 16 A 3/6 Pin Socket |
| 200 | 6 A 3/6 Pin Socket |
| 201 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 202 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM) |
| 203 | 20 mm |
| 204 | 25 mm |
| 205 | Supplying and fixing of following size G.I Saddleson existing PVC / steel conduit/ cable / pipe etc as reqd. ( Astral / Prayag/Ashirvad / Finolex/ as approvd by Engineer in charge) |
| 206 | 50 mm |
| 207 | Providing and fixing Din-rail 35 mm on existing paneletc., as required. |
| 208 | Supplying and fixing 2 way, 60 Amp, two way connectorson the existing looping box including connection etc as required. |
| 209 | Supplying and fixingBakelite Sheetof following size with screw in the existing looping box/ panelincluding cutting the sheet to required shape and size complete etc as reqd. |
| 210 | 6 mm thick |
| 211 | Supplying and installation of PVC Exhaust fanwith louver shutter of following sweep sweep in the existing opening, including making good the damage, connection, testing , commissioning etc as required.(Havells / C&G / Orient / Usha / Almonard/ Atomberg) |
| 212 | 250 mm sweep |
| 213 | Supplying and installation of following sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(HavellsTurbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard) |
| 214 | 300 mm sweep |
| 215 | Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge. |
| 216 | 150 mm sweep. |
| 217 | 200 mm sweep. |
| 218 | 250 mm sweep. |
| 219 | 450 mm sweep. |
| 220 | Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts,etc. as required. |
| 221 | Supply and installation of following sweep size, 220 V, wall mounted fan along withspeed regulator unit for speed control, on the existing wall,including connection, testing, commissioning etc. as required. (Make: Atomberg /Crompton/Havells/Orient/Usha/Bajaj/Almonard) |
| 222 | 400 mm sweep |
| 223 | Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc.,complete as per the direction of the engineer-in-charge. |
| 224 | Supply, installation, testing and commissioning of surface mountedLED downlighter luminaire inmetallic housing, with a minimum system lumen output of 1500 lumen andwith a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 225 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty ofAtomberg/ Usha/ Orient / Havells /Cromptonmake) |
| 226 | 4 Feet Batten Fitting |
| 227 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1200 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, THD = 10%, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 228 | Supply, installation, testing and commissioning of Bulk Head LED fittings with minimum 1000 lumens, efficacy not less than 100 lm / watt, having High grade polycarbonate / CRCA housing,housing with diffused optic, CCT 5700- 6500 K, CRI >70, PF > 0.9, THD< 10%, 50,000burning hours lifetime @L70 & SPD Device of appropriate Kv to support its minimum 5 Year life warranty |
| 229 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen andwith a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 230 | Supply, installation, testing and commissioning of surface mountedLED downlighter luminaire inmetallic housing, with a minimum system lumen output of 1800 lumen andwith a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 231 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 232 | Single pole |
| 233 | Double pole |
| 234 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 235 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(Note : DB should be suitable for RCCB/RCBO as incomer.) |
| 236 | 12 way , Double door |
| 237 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required |
| 238 | For 10/12 way, Double door SPN MCBDB |
| 239 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 240 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 241 | 40 A Double pole |
| 242 | 63 A Double pole |
| 243 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 244 | 40 ATriple pole and neutral |
| 245 | 63 ATriple pole and neutral |
| 246 | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 247 | 6 to 16 way,Double door |
| 248 | Supplying, installation, testing & commissioning of double door , outdoortotally enclosed, dust and vermin proof, cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area not be less than 0.4sq.mtr (Approx.) & depth of 250 mm fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & fi nishing complete with 7 tank process for powder coating in approved shade, having 160 Amp capacity extensible type TPN aluminium alloy bus bars of hightonductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than |
| 249 | 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common allumiium earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch 10 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- |
| 250 | 100 Amp 4 pole MCCB, 36 Ka (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magneticwith Spreader Link & Extended Rotary Handle, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In -1No. |
| 251 | 63 Amp 4 poleMCCB ,25 Ka (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magneticwith Spreader Link & Direct Rotary Handle, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In - 1No. |
| 252 | 32 Amp 2 pole MCB, 10 Ka (Ics=Icu) at 220 V Short CKt. Current rating - 4 No. |
| 253 | Space for DP MCB-4 No. |
| 254 | Multi-function meter (MFM) with to read V, I, Hz, PF,KW & KWH complete with 3 Nos. resin cast CTs of 250/5 Amp, class accuracy 5P10 and 15 VA burden, with control wiring with backup MCB\"s & selector switch - 1 Set. |
| 255 | LED type Phase Indicating lamp 3 Nos- 1Set |
| 256 | Danger notice plate -1 No. |
| 257 | Supplying, installation, testing & commissioning of double door , outdoortotally enclosed, dust and vermin proof, cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area not be less than 0.4sq.mtr (Approx.) & depth of 250 mm fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & fi nishing complete with 7 tank process for powder coating in approved shade, having 160 Amp capacity extensible type TPN aluminium alloy bus bars of hightonductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than |
| 258 | 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common allumiium earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch 10 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- |
| 259 | 80 Amp 4 pole MCCB, 36 Ka (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magneticwith Spreader Link & Extended Rotary Handle, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In -1No. |
| 260 | 63 Amp 2 pole MCB, 10 Ka (Ics=Icu) at 220 V Short CKt. Current rating - 2 No. |
| 261 | 32 Amp 4 pole MCB, 10 Ka (Ics=Icu) at 220 V Short CKt. Current rating - 2 No. |
| 262 | Space for 3 Phase Starter- 1 No. |
| 263 | Multi-function meter (MFM) with to read V, I, Hz, PF,KW & KWH complete with 3 Nos. resin cast CTs of 250/5 Amp, class accuracy 5P10 and 15 VA burden, with control wiring with backup MCB\"s & selector switch - 1 Set. |
| 264 | LED type Phase Indicating lamp 3 Nos- 1Set |
| 265 | Danger notice plate -1 No. |
| 266 | Supplying, installation, testing & commissioning of double door , outdoortotally enclosed, dust and vermin proof, cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area not be less than 0.4sq.mtr (Approx.) & depth of 150 mm fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & fi nishing complete with 7 tank process for powder coating in approved shade, having 160 Amp capacity extensible type TPN aluminium alloy bus bars of hightonductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than |
| 267 | 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common allumiium earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch 10 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- |
| 268 | 63 Amp 2 pole MCB, 10 Ka (Ics=Icu) at 220 V Short CKt. Current rating - 1 No. |
| 269 | 32 Amp 2 pole MCB, 10 Ka (Ics=Icu) at 220 V Short CKt. Current rating - 4 No. |
| 270 | Danger notice plate -1 No. |
| 271 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 272 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 273 | Providing & Fixing 25mmx5mm GI strip on surface or in reccessfor connections etc. as required. |
| 274 | Providing and fixing6 SWG dia GI Wire on surface or in reccess for loop earthing alongwithexisting surface/ reccess conduit / sub main wiring / cable as reqired. |
| 275 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 276 | Earthing with GI Earth plate 600mm x600mmx6mm thick including Accessories and providing mosnaryenclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. Long etc. with charcoal /coke and salt as required. |
| 277 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 278 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run) |
| 279 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 280 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 281 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 282 | Rewinding of following size ceiling fan / exhaust fan/ Wall fanmotor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted. |
| 283 | 1200mm Sweep ceiling fan |
| 284 | 1400mm Sweep ceiling fan |
| 285 | Wall Fan upto 400 mm |
| 286 | 300mm / 380 mm exhaust fan |
| 287 | 450 mm exhaust fan |
| 288 | 600mm exhaust fan |
| 289 | Providing and replacing ball bearing in following sizeceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required.(Scrap material will be retained by the contractor).(Both side shield ball bearing of SKF/ NBC /TATA ) |
| 290 | 1200mm Sweep ceiling fan. |
| 291 | 1400mm Sweep ceiling fan. |
| 292 | 300mm/ 380 mm exhaust fan |
| 293 | 450 mm exhaust fan. |
| 294 | 600 mm exhaust fan. |
| 295 | Providing and replacing the 2.5 MFD/3.15 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 296 | Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 297 | Reconditioning of the oversized bush bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor. |
| 298 | Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan.All the scrap material should be retained by the contractor. |
| 299 | Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required. |
| 300 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 301 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 302 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 303 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 304 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 305 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 306 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits. |
| 307 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit. |
| 308 | Less credit for the unserviciable items dismantled items during execution of the work. |
| 309 | Assorted MCB TP AND TP&N & OTHER SWITCHGEAR |
| 310 | Assorted PIANO Type Switches |
| 311 | Assorted PIANO Type Sockets |
| 312 | Assorted Bell push/PIANO Type |
| 313 | Assorted Call bell buzzer single phase |
| 314 | Assorted Brass batten/ angle holder/Brass Bracket |
| 315 | Assorted Fan regulator/resistance type |
| 316 | Assorted Telephone Socket outlet |
| 317 | Assorted T.V. Socket outlet |
| 318 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 319 | Assorted 1200/1400 mm sweep ceiling Fanwith blades |
| 320 | Assorted Fresh Air FAN 200/250 |
| 321 | Assorted Exhaust fan 300/380/450 |
| 322 | Assorted Wall Bracket Fittings |
| 323 | Assorted fluorescent Light Fittings |
| 324 | Assorted Bulk Head Fittings |
| 325 | less credit for the dismantled Copper wirewires from light points/ circuit/ submain/power circuit wiring,. |
| 326 | less credit for the dismantled aluminium wirewires from light points/ circuit/ submain/power circuit wiring,. |
| 327 | Assorted metal switch box. |
| 328 | Assorted MCB DB SPN with out MCBs |
| 329 | Assorted MCB DB TPN without MCBs |
| 330 | Assorted MCB SP |
| 331 | Assorted MCB DP |
| 332 | Assorted MCB TP AND TP&N |
| 333 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium conductor power cable 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC pipe as required. |
| 334 | 2 X 16 Sq.mm |
| 335 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium conductor power cable 1.1 KV grade of following size in Masonry Open Duct Loose/loop/in panel etc. complete etc as required. |
| 336 | 2 X 16 Sq.mm |
| 337 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 338 | 2 X 16 sq. mm (22mm) |
| 339 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching(75 cm deep) and refilling etc. |
| 340 | 50 mm dianominal bore |
| 341 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 342 | 63 mm dia ( OD-63 mm & ID-51 mm Nominal) |
| 343 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 344 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. |
| 345 | 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 346 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 347 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 348 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. |
| 349 | Bituminous portion |
| 350 | The road crossings of power cablethrough trenchless boring. Trenchless boring using Manual/ Machine Moling techniqueat 0.75 metre below the ground level for following size pipes,including survey of under ground utilities,excavation of pits,moling with the hole size not exceeding 20% of the pipe dia,backfilling, compaction and restoration of the pits to original condition etc. as required.The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction andrestoration of the pits to original condition.Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department.The length of the Hole (excluding the sizes of the pits on both ends) shall |
| 351 | be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i)Upto 150 mm dia DWC HDPE / G.I. /PVC |
| 352 | Supplying and fixing polycarbonate weatherproof, IP66 outdoor type cable junction box with minimum dimensions of 155 mm x 210 mm x 92 mm on a pole, complete with the following accessories fixed in, and two sets of 25 mm x 3 mm GI clamps with G. I. bolts, nuts and washers, for mounting on a street light pole, including connections etc., complete as required. i) Din-rail suitable for fixing the following accessories-1 Nos. ii) Feedthrough terminals 75 A-4 Nos with endplate as required. iii) shorting link -2 Nos.v) End Clamps -2 Nosvi) SP MCB\"C\" curve, 10KA, 6 A - 1Nos.v) PVC Cable Gland- 2 Nos Junction box make: (MakeHensel KF 1600G/ Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO)Terminal Bock: Connect well/Elmex/ Phoenix/ Wago/ EssenCable Gland : Hensel/ Dowells/ Barco/ Connectwell/ Elmex /Eaton/ Legrand |
| 353 | Add 1.0633 multiplying factor for GST on DSR |