}

Tender For Providing Maintenance Of Internal Electrification Including Connection Of Different Equipments In Indoor Hall And Judo Hall At Ddssc Complex Badharghat, badharghat-Tripura

Public Works Department has published Tender For Providing Maintenance Of Internal Electrification Including Connection Of Different Equipments In Indoor Hall And Judo Hall At Ddssc Complex Badharghat. Submission Date for this Tender is 21-09-2023. Bolts Tenders in badharghat Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

39433035
Tender For Providing Maintenance Of Internal Electrification Including Connection Of Different Equipments In Indoor Hall And Judo Hall At Ddssc Complex Badharghat
Open Tender
NCB
Tripura
Badharghat
21-09-2023

Tender Details

Providing Maintenance Of Internal Electrification Including Connection Of Different Equipments In Indoor Hall And Judo Hall At Ddssc Complex Badharghat-Wiring For Light / Fan / Exhaust Fan / Call Bell Point With 2 X1.5 Sq. Mm Pvc Insulated Copper Conductor Cable ( Fr ) In Pvc Casing And Capping Complete With 6 / 10 Amps Modular Type Switch, Cover Plate, Surface Modular Switch Board Including Connection Etc As Required:- 2 Short Point 3 Medium Point 4 Long Point 5 Providing And Fixing Of 3 Pin 6 / 10 Amps Plug Point Withmodulartype 6 / 10Ampsswitch Andsocketincludingconnectionwith 2X1.5 Sq. Mm Pvc Insulated Copper Conductor Cable ( Fr ) On Surface Modularswitch Board, Earthing The 3Rd Pin Etc. As Required:- 6 Providing And Fixing Of 3 / 6 Pin 16 / 20 Amps Plug Point Withmodulartype 16 / 20Ampsswitch Andsocketincludingconnectionwith 2X2.5 Sq. Mm Pvc Insulated Copper Conductor Cable ( Fr ) On Surface Modular Switch Board, Earthing The 3Rd Pin Etc. As Required:- 7 Wiring For Circuit / Sub-Main With Following Sizes Pvc Insulated Copper Conductor Cable ( Fr ) In Pvc Casing And Capping Etc. As Required. 8 2 X 1.5 Sq.Mm 9 2 X 2.5 Sq.Mm 10 2 X 4 Sq Mm 11 2 X 6 Sq Mm 12 4 X 4 Sq Mm 13 4 X 6 Sq Mm 14 4 X 10 Sq Mm 15 4 X 16 Sq Mm 16 Wiring For Circuit / Sub-Main With The Following Sizes Of Pvc Insulated Copper Conductor Cable ( Fr ) In Existing Pvc Casing Capping / Conduit In Recess / Surface Including Connection Etc. As Required:- 17 1 X 1.5 Sq Mm 18 1 X 2.5 Sq Mm 19 1 X 4 Sq Mm 20 1 X 6 Sq Mm 21 1 X 10 Sq Mm 22 4 X 25 Sq Mm 23 Supplying And Fixing Of The Following Pvc Casing Capping With All Accessories Etc. As Required. 24 25Mm X 12Mm 25 32Mm X 12Mm 26 Supplying And Fixing Of The Following Sizes Pvc Conduit ( Medium Gauge ) On Surface With All Accessories Etc. As Required. 27 19 / 20 Mm Dia 28 25 Mmdia 29 32 Mm Dia 30 Supplying And Fixing Of The Following Electrical Accessories Including Necessary Connection Etc. As Required. 31 5 / 6 Amps Piano Type Switch 32 16 / 20 Amps Piano Type Switch 33 3 Pin 5 / 6 Amps Piano Type Socket 34 3 / 6 Pin 16 / 20 Amps Piano Type Socket 35 Electronic 4 Step Mini Fan Regulator 36 Electronic 5 Step Fan Regulator 37 Pandent Holder 38 Angle / Batten Holder 39 Ceiling Rose 40 2.5 Mfd Fan Capacitor 41 3Mm Thick Bakelite Sheet 42 32 Amps Dp Kit Kat Switch:- 43 Supplying And Fixing Of The Following Sizes Gi ( In Recess ) And Plastic ( On Surface ) Modular Switch Boards Etc. As Required. 44 1-2 Module Plastic Switch Board:- 45 3 Module Plastic Switch Board:- 46 4 Module Plastic Switch Board:- 47 6 Module Plastic Switch Board:- 48 8 Module Plastic Switch Board:- 49 12 Module Plastic Switch Board:- 50 Supplying And Fixing Of The Following Sizes Modular Type Cover Plates For Gi / Plastic Modular Switch Boards Etc. As Required. 51 1-2 Module :- 52 3 Module :- 53 4 Module :- 54 6 Module :- 55 8 Module :- 56 12 Module :- 57 Supplying And Fixing Of The Following Modular Accessories Including Necessary Connection Etc. As Required. 58 6 / 10 Amps One Way Sp Switch ( 1M ) :- 59 16 / 20 Amps One Way Sp Switch ( 1M ) :- 60 Bell Push Sp ( 1M ) :- 61 32 Amps One Way Dp Switch ( 2M ) :- 62 3 Pin 6 / 10 Amps Socket Outlet ( 2M ) :- 63 3 / 6 Pin 16 / 20 Amps Socket Outlet ( 2M ) :- 64 3 / 6 Pin 25 Amps Socket Outlet ( 2M ) :- 65 4 Step Fan Regulator ( 1M ) :- 66 5 Step Fan Regulator ( 2M ) :- 67 Blank Plate ( 1M ) :- 68 20 / 25 Amps Single Phase Motor Starter Switch ( 2M ) :- 69 Earthing With 40 Mm Dia G.I. Earth Pipe ( Medium Gauge ) 4.5 M. Long Complete With Masonry Enclosure On Top Ci Cover Plate Size 12X 12 Having Locking Arrangement Including Cc Work, Holes On Earth Pipe Etc. As Required. 70 Extra For Using Salt ( 5 Kg ) And Charcoal ( 46Kg ) For Pipe Earth Electrode As Required. 71 Proving And Fixing / Drawing Of 4.06 Mm Dia ( 8 Swg ) G.I. Wire On Surface Or In Existing G.I / Pvc / Polythene Pipe For Loop Earthing As Required. 72 Supplying And Drawing 2.5 Sq. Mm Copper Conductor Wire Along With Other Wire For Loop Earthing Including Connection Etc. As Required. 73 Providng And Laying 15Mm Dia ( Medium Gauge ) G.I. Pipe For Drawing Of4.06Mm ( 8Swg ) Dia G.I. / Copper Wire Forearth Connection From Earth Electrodes Etc As Required. 74 Supply And Fixing Of 25Mm X 5Mm Gi Strip On Wall / Floor Of The Building For Horizontal / Vertical Run Including Necessary Spacers And Porcelain Insulators At Regular Intervals. 75 Supply And Fixing Of 25Mm X 3Mm Copper On Walls / Floor Of The Building For Horizontal / Vertical Network Including Necessary Spacers And Porcelain Insulators At Regular Intervals. 76 Supplying & Fixing Of 1200 Mm Sweep White Color Ac Ceilingfan Capacitor Typedouble Ball Bearing Complete With 300 Mm Down Rod, Canopies, Shackles, 3Nos Blades, Including Wiring The Down Rod With 2X1.5 Sqmm Pvc Insulated Copper Conductor Cable ( Fr ) ( Isi Marked, Bee 1Star / Minimum Service Value 4.0 M3 / Min / W ) : - 77 Supplying & Installation Of 225 / 230 Mm Sweep Metalic Body Exhaust Fan Including Connection Etc As Required:- 78 Supplying & Installation Of 300 Mm Sweep Metalic Body Exhaust Fan Including Connection Etc As Required:- 79 Supplying & Installation Of Shutter For 225 / 230 / 300 Mm Sweep Metalic Body Exhaust Fan In The Existing Hole As Required:- 80 Dismantling The Existing Ceiling Fan And Making Winding By ( 34 / 35 / 36 S.W.G ) Copper Wire, Varnish, Oiling, Greasing And Re-Fixing The Same Including Wiring The Down Rod Of Standard Length ( Up To 30 Cm ) Etc. As Required :- 81 Supplying And Fixing Of 20 Mm Dia Extra Down Rod ( Gi Pipe Medium Guage ) With Necessary Hole For Installation Of Ceiling Fan As Required. 82 Making Different Sizes Of Hole In The Wall For Fixing Of Exhaust Fan Including Finishing The Same With Cement Plastering And Painting Etc As Required: 83 Supplying And Fixing Of Following Luminaries Complete Withnecessary Accessories And Connection Etc. As Required ( Commercial Lighting Fixtures With 50, 000 Burning Hours ) :- 84 Box Type Single Ftl Fittings Of Crca Steel Sheet Housing Complete With 36 / 40 W Ftl, Electronic Ballast And High Quality Reflector Cover : - 85 Box Type Double Ftl Fittings Of Crca Steel Sheet Housing Complete With 2 Nos. 36 / 40 W Ftl, Electronic Ballast And High Quality Reflector Cover: - 86 Bulk Head Fittings With Frosted / Clear Glass Suitable For Gls Or Retrofit Cfl / Led ( Without Lamp ) : - 87 Decorative Wall Mounting Fancy Bracket Light Fixture Suitable For Gls Or Retrofit Cfl / Led ( Without Lamp ) : - 88 Supplying And Fixing Of The Following Lamps & Accessoriesincluding Connection Etc. As Required. 89 36 / 40 Watt T-8 / T-12 Ftl Lamp:- 90 36 / 40 Watt Electronic Ballast:- 91 Ftl Starter:- 92 Supplying And Fixing Of Following Surface / Recess Mounted Led Luminaries In Powder Coated Die Cast Housing Complete With High Efficiency Polycarbonate Diffuser And Necessary Connection Etc.As Required ( With 50000 Burning Hours And Minimum Lumen Output Of 100 Lm / Watt ) :- 93 Surface Mounted Integrated 20 Watt Led Batten With Polycarbonate Diffuser:- 94 Surface Mounted Box Type Batten Suitable For Single 18 / 20 Watt Integrated Led Tube Lamp ( Without Lamp ) :- 95 Surface Mounted Box Type Batten Suitable For Double 18 / 20 Watt Integrated Led Tube Lamp ( Without Lamp ) :- 96 Surface Mounted Round / Square Shaped 12 Watt Led Downlight With Integral Driver And High Quality Polycarbonate Diffuser:- 97 Surface Mounted Round / Square Shaped 18 / 20 Watt Led Downlight With Integral Driver And High Quality Polycarbonate Diffuser:- 98 Supplying And Fixing Of Following Outdoor Led Luminaries In Powder Coated Die Cast Housing Complete With Heat Resistant Tempered Glass / Diffuser Including Necessary Connection Etc. As Required ( 50000 Burning Hours And Minimum Lumen Output Of 100 Lm / Watt ) :- 99 180 Watt Led Flood Light Fixture With Integral Driver And Secondary Lens ( Ip 66 ) :- 100 200 Watt Led Flood Light Fixture With Integral Driver And Secondary Lens ( Ip 66 ) :- 101 Supplying And Fixing Of Following Led Tubes, Retrofit Bulbs / Lamps For Led Luminaries Including Necessary Connection Etc. As Required:- 102 18 / 20 Watt Led Tube With Integral Driver And Polycarbonate Diffuser ( 50000 Burning Hours And Minimum Lumen Output Of 100Lm / Watt ) :- 103 9 Watt Led Retrofit Lamp With Polycarbonate Body And Aluminium Heatsink :- 104 12 Watt Led Retrofit Lamp With Polycarbonate Body And Aluminium Heatsink :- 105 Supplying And Installation Of Bus Bar Chamber Of The Following Ratings And Sizes Made Of Steel Sheet Enclosure With All Accessories Including Necessary Connection Etc. As Required:- 106 100 Amps 415 Volts Four Strip Copper Busbar Chamber 4 Ways Of Size ( 455Mmx330mmx120mm ) :- 107 Supplying And Installation Of Fuse Unit Kitkat / Hrc / Hbc Of The Following Ratings In Existing Main Switch / Panel Board Including Necessary Connection Etc As Required:- 108 100 Amps Kitkat Porcelain Fuse Unit With Base ( Rewireable ) 109 200 / 250 Amps Kitkat Porcelain Fuse Unit With Base ( Rewireable ) :- 110 Supplying And Installation Of Powder Coated Steel Sheet Enclosure ( Mcb Db ) Suitable For 240 / 415 Volts Mcb / Isolator / Rccb ( Sp / Spn / Dp / Tp / Tpn / Fp ) Complete With Necessary Bus Bar, Neutral Link, Din Rail, Earth Bar Etc I / C Connectionas Required. 111 2 Way Spn Mcb Db ( Single Door ) :- 112 4 Way Spn Mcb Db ( Single Door ) :- 113 ( 2+6 ) / 8Way Spn Mcb Db ( Double Door ) :- 114 ( 2+10 ) / 12Way Spn Mcb Db ( Double Door ) :- 115 4Way Horizontal Tpn Mcb Db ( Double Door 116 6Way Horizontal Tpn Mcb Db ( Double Door ) :- 117 Supplying And Installation Of Powder Coated Steel Sheet Enclosure For 415 Volts Mccb ( Tp / Fp ) Complete With Necessary Connection Etc As Required:- 118 Enclosure Suitable For Mccb Upto 100 Amps:- 119 Supplying & Installation Of 10 Ka Breaking Capacity, B / C Curve Mcb Of Following Ratings In The Existing Mcb Db Including Connectionas Required:- 120 6 To 32 Amps Sp Mcb:- 121 6 To 32 Amps Dp Mcb:- 122 6 To 32 Amps Tpn Mcb:- 123 Supplying & Installation Of Isolators Of Following Ratings In The Existing Mcb Db Including Connection Etc As Required:- 124 40 Amps Dp Isolator:- 125 40 Amps Fp Isolator:- 126 Supplying & Installation Of Tp / Fp Mccb Of Following Ratings In The Existing Mccb Enclosure / Panel Board Including Connection Etc As Required ( Ics=100% Of Icu With Adjustable Settings ) :- 127 16 To 100 Ampstp Mccb, Breakingcapacity 16 / 18Ka ( Thermal Magnetic ) :- 128 16 To 100 Amps Fp Mccb, Breakingcapacity 16 / 18Ka ( Thermal Magnetic ) :- 129 200 Amps Fp Mccb, Breakingcapacity 25Ka ( Thermal Magnetic ) :- 130 250 Amps Fp Mccb, Breakingcapacity 36Ka ( Thermal Magnetic ) :- 131 Supplying & Installation Of Following Switchgear Accessories Including Connection Etc As Required:- 132 Copper Spreader Links / Terminals ( Set Of 8 ) For 160A-250A Fp Mccb:- 133 Supplying And Laying Of The Following Sizes Xlpe Insulated Pvc Sheathed Aluminium Conductor Armoured Cable With Necessary Connection Etc As Required 134 3.5 Core 35 Sq Mm 135 Supplying And Laying Offollowing Sizes Xlpe Insulatedpvc Sheathed Aluminium Conductor Un-Armoured Cableincludingnecessary Connection Etc As Required. 136 3 Core 4 Sq Mm 137 3 Core 6 Sq Mm 138 Supplying & Fixing Of G.I. Pipe ( Medium Gauge ) Bracket Fabricated At Suitable Angle For Fixing Of Outdoor Light On Wall / Rcc Base With Necessary Ms Clamp, Nut, Bolt Etc As Required:- 139 Supplying & Fixing Of 40 Mm Dia G.I Pipe ( Medium Gauge ) Cross Bar For Fixing Of Ceiling Fan / Luminaries Including Painting & Necessary Accessories Etc As Required. 140 Supplying Of ‘U’ Clamp Made With 40Mm X 6 Mm Ms Flat And Fixing With Necessary Fasten Nuts Including Painting Etc As Required. 141 Supplying &Fixing Of 12Mm Thick Marine Plywood Conforming To Is:710 With Necessary Painting Etc As Required:- 142 Excavation Of Earth For Cable Trench Of 800Mm Depth & 300Mm Width In All Kinds Of Soil Including Back Filling Of Cable Trench With The Excavated Soil With 20Cm Layer Of Sand, 3.5 Nos Bricks Per Metre For Protection Including Ramming, Consolidating To The Original Shape As Per Dirrection Of Site Engineer :- 143 Drawing Of Armoured / Un-Armoured Cable With Proper Saddling Etc As Required:-

Key Value

Document Fees
INR 1000 /-
EMD
INR 18593.0 /-
Tender Value
INR 9.29 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail