Tender For Development Of Sports Complex At Sector – 19, Dwarka.Sub Head:Sitc Of Dg Set At Sector-19 Dwarka.; 1 Part-I Sitc Of D.G Setproviding, Installing, Testing & Commissioning Of Silent Type D.G Set Having Prime Power Rating Of 500 Kva, 415 Volts At 1500 Rpm, 0.8 Lagging Power Factorat 415 Voltsuitablefor 50 Hz 3 Phase System & For 0.85 Loadfactoralong Withsuitableratingelectricalmanual Control Panel And Consisting Of The Following:A ) Diesel Enginedieselengine 4Stroke Water Cooled, Electric Start Of Suitable Bhpat1500 Rpmsuitable For Delivering Required Output Of Alternatorat Ntpconditionsandconfirming Tobs 5514, Bs 649, Is 10000, Capable Oftaking10% Over Loadingfor Onehour After12 Hour Of Continuous Operation. The Engine Will Be Fitted Complete With All The Required Accessories Along With Electronic Governor Ao.B ) Engine Mounted Instrument Panel Fitted With And Having Digital Display For Following:I ) Start-Stop Switch With Key.Ii ) Water Temperature Indication.Iii ) Lubrication Oil Pressure Indication.Iv ) Lubrication Oil Temperature Indicationv ) Battery Charging Indication.Vi ) Rpm Indication.Vii ) Over Speed Indication.Viii ) Low Lubrication Oil Trip Indication.Ix ) Engine Hours Indication.X ) Inbuilt Diesel Tank.C ) Alternatorsynchronous Alternator Rated 500 Kva, 415 Voltat 1500 Rpm 3 Phase 50 Hz Ac Supply With 0.8 Lagging Power Factor At 40º C, 50% Rh & At 1000Meter Msl. The Alternator Shall Be Having Spdp Enclosure, Brushless, Continuous Duty, Self-Excited Andself-Regulated Through Avr Conforming To Is 4722 / Iec 60034 Suitable For Tropical Condition And With Class H Insulation.D ) Base Frame Foundationboth The Engine And Alternator Shallbemounted On Suitable Base Frame Made Ofm.S. Channel With Necessary Reinforcement Which Shall Be Installedon Suitablecementconcretefoundationand Vibration Isolation Arrangement As Per Recommendations Of Manufacturer.E ) Fuel Tankdaily Service Fuel Tank Of 700Ltrs. Capacity Fabricated Out Of 3Mm Thick M.S Sheet Complete Withall Standard Accessories Andfuel Piping Between Fuel Tank And Diesel Engine With M.S Class C Pipes Of Suitable Diameter. Complete With Valves, Level Indicator & Accessories As Required As Per Specifications:F ) Exhaust Systemdry Exhaust System Manifoldwith Residentialexhaust Silencer.G ) Starting System12 V / 24 Vdcstarting SystemcomprisingofstartermotorS Voltage Regulator And Arrangement For Initial Excitation Completewith Suitable Nos. Of Batteries ( 180 Ah Capacity Lead Acid Type ) As Required As Per Specification.H ) Acoustic And Weather Proof Enclosure With Arrangement For Fresh Air Intake For Cooling Of The Engine And Alternator, Extraction, Discharginghot Air Into The Atmosphereas Per Specifications, For In House Power Generation For Emergency Loads. ( Note:- D.G Set Shall Confirm With Latest Cpcb- Iv+ Guidelines ) 2 Providing, Installing, Testing & Commissioning Of Silent Type D.G Set Having Prime Power Rating Of 83 Kva, 415 Volts At 1500 Rpm, 0.8 Lagging Power Factorat 415 Voltsuitablefor 50 Hz 3 Phase System & For 0.85 Loadfactoralong Withsuitableratingelectricalmanual Control Panel And Consisting Of The Following:A ) Diesel Enginedieselengine 4Stroke Water Cooled, Electric Start Of Suitable Bhpat1500 Rpmsuitable For Delivering Required Output Of Alternatorat Ntpconditionsandconfirming Tobs 5514, Bs 649, Is 10000, Capable Oftaking10% Over Loadingfor Onehour After12 Hour Of Continuous Operation. The Engine Will Be Fitted Complete With All The Required Accessories Along With Electronic Governor Ao.B ) Engine Mounted Instrument Panel Fitted With And Having Digital Display For Following:I ) Start-Stop Switch With Key.Ii ) Water Temperature Indication.Iii ) Lubrication Oil Pressure Indication.Iv ) Lubrication Oil Temperature Indicationv ) Battery Charging Indication.Vi ) Rpm Indication.Vii ) Over Speed Indication.Viii ) Low Lubrication Oil Trip Indication.Ix ) Engine Hours Indication.X ) Inbuilt Diesel Tank.C ) Alternatorsynchronous Alternator Rated 125 Kva, 415 Voltat 1500 Rpm 3 Phase 50 Hz Ac Supply With 0.8 Lagging Power Factor At 40º C, 50% Rh & At 1000Meter Msl. The Alternator Shall Be Having Spdp Enclosure, Brushless, Continuous Duty, Self-Excited Andself-Regulated Through Avr Conforming To Is 4722 / Bs 2613 Suitable For Tropical Condition And With Class H Insulation.D ) Base Frame Foundationboth The Engine And Alternator Shallbemounted On Suitable Base Frame Made Ofm.S. Channel With Necessary Reinforcement Which Shall Be Installedon Suitablecementconcretefoundationand Vibration Isolation Arrangement As Per Recommendations Of Manufacturer.E ) Fuel Tankdaily Service Fuel Tank Of 225Ltrs. Capacity Fabricated Out Of 3Mm Thick M.S Sheet Complete Withall Standard Accessories Andfuel Piping Between Fuel Tank And Diesel Engine With M.S Class C Pipes Of Suitable Diameter. Complete With Valves, Level Indicator & Accessories As Required As Per Specifications:F ) Exhaust Systemdry Exhaust System Manifold With Residential Exhaust Silencer.G ) Starting System12 V / 24 Vdcstarting SystemcomprisingofstartermotorS Voltage Regulator And Arrangement For Initial Excitation Completewith Suitable Nos. Of Batteries ( 25-Plate 180 Ah Capacity Lead Acid Type ) As Required As Per Specification.H ) Acoustic And Weather Proof Enclosure With Arrangement For Fresh Air Intake For Cooling Of The Engine And Alternator, Extraction, Discharginghot Air Into The Atmosphereas Per Specifications, For In House Power Generation For Emergency Loads. ( Note:- D.G Set Shall Confirm With Latest Cpcb- Iv+ Guidelines ) 3 Supply, Installation, Testing And Commissioning Of Automatic Mains Failure Control Auto By-Pass Panel, Suitable For 500Kva Silent Type D.G Set Complete With All The Protection And Digital Display Of All The Parameters With Multifunction Controller, Control Cabling From Amf Panel To Diesel Engine And Elsewhere If Required, All Complete And Inter Locking The Following:A ) 2 Nos 4 Pole 1000 Amp Power Contactor.B ) Auto / Manual / Test / Off Selector Switch.C ) 2 Nos. Over Voltage Relay, 2 Nos. Reverse Power Relay And 2 Nos. Under Voltage Relay.D ) 3 Sets Of Current Transformer 15 P 10 Accuracy For Protection And 15 Va Class-I For Metering.E ) Indication Lamp For Load On Mains And Load On Set..F ) Battery Chargerwith Auto Cutg ) On / Off / Control Circuit Switch With Indicator.H ) Audio / Video Annunciation Fori ) Low Lubricating Oil Pressureii ) Engine Over Speed Iii ) Engine Fails To Start Iv ) Full Load / Maximum Load Warningfor Automatic Switching On / Off Of D.G Supply. 4 Supply, Installation, Testing And Commissioning Of Automatic Mains Failure Control Auto By-Pass Panel, Suitable For 83Kva Silent Type D.G Set Complete With All The Protection And Digital Display Of All The Parameters With Multifunction Controller, Control Cabling From Amf Panel To Diesel Engine And Elsewhere If Required, All Complete And Inter Locking The Following:I ) 2 Nos 4 Pole 250 Amp Power Contactor.J ) Auto / Manual / Test / Off Selector Switch.K ) 2 Nos. Over Voltage Relay, 2 Nos. Reverse Power Relay And 2 Nos. Under Voltage Relay.L ) 3 Sets Of Current Transformer 15 P 10 Accuracy For Protection And 15 Va Class-I For Metering.M ) Indication Lamp For Load On Mains And Load On Set..N ) Battery Chargerwith Auto Cuto ) On / Off / Control Circuit Switch With Indicator.P ) Audio / Video Annunciation For I ) Low Lubricating Oil Pressureii ) Engine Over Speed Iii ) Engine Fails To Start Iv ) Full Load / Maximum Load Warningfor Automatic Switching On / Off Of D.G Supply. 5 Earthing With Copper Earth Plate 600Mm X 600Mm X 3Mm Thick Including Accessories And Providing Masonry Enclouser With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal Or Coke And Salt Complete As Required. 6 Earthing With Gi Earth Plate 600Mm X 600Mm X 6Mm Thick Including Accessories And Providing Masonry Enclouser With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal Or Coke And Salt Complete As Required. 7 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 8 Providing And Fixing 25 Mm X 5 Mm Gi Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required