Provision Of Fire Exit Signage & Refilling Of Fire Fighting Extinguishers In Glm Hospital-Electrical Work ; 2 Od7016 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Group C 3 Od7018 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 4 Od7019 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( C ) 15 / 16 Amp Switch 5 Od7020 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 Amp Switch 6 Od7022 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 Amp Socket Outlet 7 Od7023 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedpvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 8 Od7024 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedpvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 9 Od7026 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required ( A ) Single Pole 10 Od7030 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 A 11 Od7037 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 12 Module ( 200 Mmx150 Mm ) 12 Od7038 / 2023-2024: Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required 13 Od7039 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 12 Way Double Door 14 Od7040 / 2023-2024:Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal / Coke And Salt ) As Required. 15 Od7041 / 2023-2024:Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Reqd. 16 121.1:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374- 2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 17 Od7065 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required ( A ) Upto 35 Sq. Mm 18 Od7066 / 2023-2024:Laying Of One No Pvc Insulated And Pvc Sheathed / Xple Al Conductor Armoured Power Cable Of 1.1Kv Grade Of Following Sizeon Wall Surface As Required. Up To 35 Sq, Mm ( Clamped With 1Mm Thick Saddle ) 19 Od7074 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5 Sq. Mm 20 Approved Item 21 122.2.131:Supply, Installation, Testing And Commissioning Of 1.5 Ton, 5 Star Rated Inverter Split Air Conditioner With Rotary Compressor ( R32 Refrigerant ) Having Copper Condenser Complete With Outdoor Unit As Required. 22 122.2.117:S / I / T / C Of Copper Pipe For Split Ac 23 122.2.115:S / I / T / C Of 4 Kva Voltage Stabilizer Having Input Voltage 150V-270V And Output Voltage 195-245V 24 122.1.3:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*10 Sqmm 25 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 26 122.2.33:Sitc Of 60W Led Street Light Luminaire Fitted With Lens, Top Opening Driver Cover Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =60 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 27 122.2.190:Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe ( Medium Class ) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. 28 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 29 122.1.35:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Un-Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*4 Sqmm 30 122.2.114:S / I / T / C Of Stand For Split Ac 31 122.1.54:Supply Of Extra Drain Pipe 32 122.2.119:S / I / T / C Of 3 Core, 4 Sqmm. Electrical Wire For Air Conditioner