}

Tender For Annual Maintenance And Minor Hvac Works At Main Building , Lecture Theatre Complex , Animal House , Mendeleev , H Cross , G1 , Dining Block, Guest House, Chiller Plant Room In Iiser Pune Campus During Year 2023-24., pune-Maharashtra

Boards / Undertakings / PSU has published Tender For Annual Maintenance And Minor Hvac Works At Main Building , Lecture Theatre Complex , Animal House , Mendeleev , H Cross , G1 , Dining Block, Guest House, Chiller Plant Room In Iiser Pune Campus During Year 2023-24.. Submission Date for this Tender is 11-09-2023. HVAC Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

39213646
Corrigendum : Tender For Annual Maintenance And Minor Hvac Works At Main Building , Lecture Theatre Complex , Animal House , Mendeleev , H Cross , G1 , Dining Block, Guest House, Chiller Plant Room In Iiser Pune Campus During Year 2023-24.
Open Tender
Indian
Maharashtra
Pune
11-09-2023

Tender Details

Annual Maintenance And Minor Hvac Works At Main Building , Lecture Theatre Complex , Animal House , Mendeleev , H Cross , G1 , Dining Block, Guest House, Chiller Plant Room In Iiser Pune Campus During Year 2023-24. 1 Please Note That Quoted Rates Are Inclusive Of Taxes, Labor, Transportation, Royaltie Etc. Nothing Extra Shall Be Paid Separtely. 2 Supply Installation Testing And Commissioning Of 2.0 Tr / 1.8 Tr Capacity Hiwall Type Indoor Unit With Iseer Value Of Min 4.6 Or Above With Cordless Remote Control & Outdoor Unit With Copper Condenser Coil Mounted With Suitable Metal Stand With R410 Or Equivalent Green Refrigerant Gas Only With Inverter Compresoor Only, This Item Includes 3 Meter Copper Pipe Also. Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make : Toshiba / Mistubishi / Daikin / Hitachi / Blue Star / Lg / Samsung / Carrier / Voltas ) 3 Supply Installation Testing And Commissioning Of 1.5 Tr Capacity Hiwall Type Indoor Unit With Iseer Value Of Min 4.6 Or Above With Cordless Remote Control & Outdoor Unit With Copper Condenser Coil Mounted With Suitable Metal Stand With R410 Or Equivalent Green Refrigerant Gas Only With Inverter Compresoor Only, This Item Includes 3 Meter Copper Pipe Also. Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make : Toshiba / Mistubishi / Daikin / Hitachi / Blue Star / Lg / Samsung / Carrier / Voltas ) 4 Supply Installation Testing And Commissioning Of 1.0 Tr Capacity Hiwall Type Indoor Unit With Iseer Value Of Min 4.6 Or Above With Cordless Remote Control & Outdoor Unit With Copper Condenser Coil Mounted With Suitable Metal Stand With R410 Or Equivalent Green Refrigerant Gas Only With Inverter Compresoor Only, This Item Includes 3 Meter Copper Pipe Also.Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make : Toshiba / Mistubishi / Daikin / Hitachi / Blue Star / Lg / Samsung / Carrier / Voltas ) 5 Chilled Water Cassette :- 2.0 Tr Capacity - Cassette Units With Drain Pumpsupplying, Installing, Testing And Commissioning Of Factory Built Horizontal Fan Coil Units, Blow Through Type, Nos. Complete With 3-4 Rows Deep Chilled Water Coil Of Copper Tubeand Aluminium Fins Construction Withhydrophilic Coating, One Or More Centrifugal Fans With 3 Speed Motor, Cleanable Synthetic Fibre Filters, Casing, Coil Piping Connections, Through Copper Pipes, Condensate Drain Connections With U Trap, Along With Remote And Sensors. Necessary Copper Coil Piping Connections Shall Be Provided.Cassette Units Shall Be Provided With 1.25Mm Thick Stainless Steel Extended Drain Pan With 13Mm Thick Aluminium Foil Faced Insulation To Ensure The Covering Of All Copper Connections And Valves. All Cassette Units Shall Be Suitable For 230 ± 6% Volts, 50 Cycles, Single Phase Power Supply.Noise Level Shall Be45 Db ( A ) At 1 M Distance.Fan Coil Units Shall Be Of Following Capacities As Listed. As Per Technical Specifications With All The Necessary Mounting Accessories Including Rubber Groomets For Vibration Isolation As Required For Complete Installation. ( Make - Kubic / Carrier / Cruise / Midea ) 6 Chilled Water Cassette :- 2.0 Tr Capacity - Hiwall Type Units Supplying, Installing, Testing And Commissioning Of Factory Built Horizontal Hiwall Type Units, Blow Through Type, Nos. Complete With 3-4 Rows Deep Chilled Water Coil Of Copper Tubeand Aluminium Fins Construction Withhydrophilic Coating, One Or More Centrifugal Fans With 3 Speed Motor, Cleanable Synthetic Fibre Filters, Casing, Coil Piping Connections, Through Copper Pipes, Condensate Drain Connections With U Trap, Along With Remote And Sensors. Necessary Copper Coil Piping Connections Shall Be Provided.All Hiwall Type Units Shall Be Suitable For 230 ± 6% Volts, 50 Cycles, Single Phase Power Supply.Noise Level Shall Be45 Db ( A ) At 1 M Distance. Hiwall Type Units Shall Be Of Following Capacities As Listed. As Per Technical Specifications With All The Necessary Mounting Accessories Including Rubber Groomets For Vibration Isolation As Required For Complete Installation. ( Make - Kubic / Carrier / Cruise / Midea ) 7 Supply Of Remotes All In One Type To Match All Makes Of Dx Hiwall Type Air Condition Units. ( Any Make ) 8 Supply Of Remotes To Match Lg Makes Dx Hiwall Type Air Condition Units And Vrf ( Variable Refrigerant Flow ) Indoor Units. ( Any Make ) 9 Supplying & Fixingof Copper Refrigerant Piping Of Suitable Size For 2.0 / 1.5 Tr Hiwall Air Condition Units With Minimum 9 Mm Insulation Complete From Indoor Unit To Outdoor Unit With Supports Etc. ( Make - Mandev / Indigo / Mehta Tubes ) 10 Supplying & Fixingof Copper Refrigerant Piping Of Suitable Size For 1.0 Tr Hiwall Air Condition Units With Minimum 9 Mm Insulation Complete From Indoor Unit To Outdoor Unit With Supports Etc. ( Make - Mandev / Indigo / Mehta Tubes ) 11 Supply And Installation Of L Bracket Stand For Hiwall Air Condition Outdoor Units Of All Capacity ( 1.0 / 1.5 / 1.8 / 2.0 Tr Capacities ) . ( Make - Any ) 12 Supplying & Fixing 25 Mm Size Pvc Drainage Pipe With Min 6Mm Thick Insulation I / C Cutting The Wall, Finishing Etc. As Reqd. ( Make - Astral / Ashirvad / Supreme / Finolex / Prince ) 13 Supplying & Fixing 32 Mm Size Pvc Drainage Pipe With Min 6Mm Thick Insulation I / C Cutting The Wall, Finishing Etc. As Reqd. ( Make - Astral / Ashirvad / Supreme / Finolex / Prince ) 14 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. - 3 Core * 1.5 Sq Mm ( Make - Polycab / Finolex / Rr Cables ) 15 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. - 4 Core * 4 Sq Mm ( Make - Polycab / Finolex / Rr Cables ) 16 Supply Installation Testing And Commissioning Ofof 1.1 Kw Electrical Motor With Facility To Install The Plug Type Bower Fans. Specifications Are 3 Phase Induction Motor, 4 Pole 1450 Rpm, 440 Vac, 50 Hz Supply, 1.1 Kw, 6 Rated Number Terminals Into The Terminal Box With Cover, Provision For Terminations As Per Rating, Ip55 Rating, F Class Insulation, S1 Class. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Siemns / Crompton Greaves / Abb ) 17 Supply Installation Testing And Commissioning Ofof 4.0 Kw Electrical Motor With Facility To Install The Plug Type Bower Fans. Specifications Are 3 Phase Induction Motor, 4 Pole 1450 Rpm, 440 Vac, 50 Hz Supply, 4.0 Kw, 6 Rated Number Terminals Into The Terminal Box With Cover, Provision For Terminations As Per Rating, Ip55 Rating, F Class Insulation, S1 Class. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Siemns / Crompton Greaves / Abb ) 18 Supply Installation Testing And Commissioning Ofof 12.7 Kw Electrical Motor With Facility To Install The Plug Type Bower Fans. Specifications Are 3 Phase Induction Motor, 4 Pole 1450 Rpm, 440 Vac, 50 Hz Supply, 12.7 Kw, 6 Rated Number Terminals Into The Terminal Box With Cover, Provision For Terminations As Per Rating, Ip55 Rating, F Class Insulation, S1 Class. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Siemns / Crompton Greaves / Abb ) 19 Charges Towards Upto 2 Kw Capacity Motor Preventive Servicing ( Cleaning Of Coil, Repainting Completely, Greasing And Etc. ) , The Work Should Be Done On Site Only. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 20 Charges Towards 7.5 Kw Capacity Motor Preventive Servicing ( Cleaning Of Coil, Repainting Completely, Greasing And Etc. ) , The Work Should Be Done On Site Only. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 21 Charges Towards 12.7 Kw Capacity Motor Preventive Servicing ( Cleaning Of Coil, Repainting Completely, Greasing And Etc. ) , The Work Should Be Done On Site Only. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 22 Supply Installation Testing & Commissioning Of Bearing Of Electrical Motor Capcity Upto 2 Kw. ( Make - Skf ) 23 Supply Installation Testing & Commissioning Of Bearing Of Electrical Motor Capacity Upto 7.5 Kw. ( Make - Skf ) 24 Supply Installation Testing & Commissioning Of Bearing Of Electrical Motor Capcity Upto 12.7 Kw. ( Make - Skf ) 25 Supply Installation Testing & Commissioning Of Fire Resistant Canvas Cloth For Ahu Mouth Connection. ( Make - Any ) 26 Supplying, Fixing, Testing And Commissioning Of Following Pressurization Unit Complete With Double Pump ( 2Cmh, 25Mwc ) , Ip55 Control Panel, Pressure Transmitter, Flow Meter, Interconnecting Piping & Wiring, Pn 10 As Specified. ( Model No. - Psu-225, Pn16 ) ( Make - Anergy ) 27 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 3 Tr Capacitycompressor ( Copeland Scroll 3 Phase ) , Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Copeland / Daikin / Equivalent ) 28 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 2 Tr Capacitycompressor ( Copeland Scroll Single Phase ) , Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Copeland / Daikin / Equivalent ) 29 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 1.5 Tr Capacitycompressor ( Copeland Scroll Single Phase ) , Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Copeland / Daikin / Equivalent ) 30 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 2 Tr Capacitycopper Condenser Coil, Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 31 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 2.5 Tr Capacitycopper Condenser Coil, Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 32 Supply Installation Testing And Commissioning Of Dx Hiwall Type Of 3.0 Tr Capacitycopper Condenser Coil, Work Includes Leak Testing With Nitrogen Gas And Then Vacuum Upto The Level Of Oem Recommendations And Filling Of Refrigeranr Gas. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 33 Supply Installation Testing & Commissioning Of Chilled Water 2.0 Tr Cassette Ac Drain Pump With Float Switch. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 34 Supply Of Refrigerant Gas R 134A For Centralised Centrifugal Chillers. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 35 Supply Of Refrigerant Gas R 22 For Hiwall Type Air Condition Units. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 36 Supply Of Refrigerant Gas R 410A For Hiwall Type Air Condition Units. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 37 Supply Of Refrigerant Gas R 32 For Hiwall Type Air Condition Units. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 38 Supply Of Nitrogen Gas For Air Condition Units Leak Testing, The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Any ) 39 Descaling Of 470 Tr Condenser Tubes ( Approximate 500 Nos. Of Tubes ) Of Chiller Model Ksc 087 By Supply Of Acidic Chemical Of Suitable Ph Level As Per The Condenser Approach, Rotate The Acid In The Condenser Tubes ( Min 12 Hours ) And Clean It By Using Brush Attached With The Motor, Repeat The Above Procedure Until The Condenser Approach Rnos.Es A Maximum Of 4 Degree. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 40 Descaling Of 470 Tr Evaporator Tubes ( Approximate 500 Nos. Of Tubes ) Of Chiller Model Ksc 087 By Supply Of Acidic Chemical Of Suitable Ph Level As Per The Evaporator Approach, Rotate The Acid In The Evaporator Tubes ( Min 12 Hours ) And Clean It By Using Brush Attached With The Motor, Repeat The Above Procedure Until The Evaporator Approach Reaches A Maximum Of 4 Degree. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 41 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Arepvc Fill Sheets Mx75-8.1 Lev ( 4* 12 Feet ) Part No. P85-4289-13 ( Make - Paharpur ) 42 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Arepvc Fill Sheets Mx75-8.1 Lev ( 4* 12 Feet ) Part No. P85-4289-14 ( Make - Paharpur ) 43 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Arefill Retainer Cap 44 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Aretarget Nozzles 45 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Arelubricating Oil For Cooling Tower Motors Sae 30 ( Make - Any ) 46 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Aretube 2 Od * 20 Ga Thk * 600 Erw Gi 47 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Aretube 2 Od * 20 Ga Thk * 670 Erw Gi 48 Supply Of Cooling Tower Spare Materials Of Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur, Item Details Areuni-O Strip ( For Leakage Recovery ) 49 Labour Charges For Existing Pvc Fills Cleaning And Reinstallation Of Good Fills And Installation Of New Pvc Fills With Its Accessories Like Fill Retainer Cap, Tubes Uni Ostrip And Target Nozzles By Dismantling The Entire Cooling Tower & Etc. The Cooling Tower Details Are, Model No. 6151, Tb / Sr No. 12-2F0078 And Make - Paharpur ( Cross Flow ) . 50 Supply Of Scacil 9800 ( Regular Treatment ) 51 Supply Of Scacil 9240 ( Regular Treatment ) 52 Supply Of Scacil 9020 ( Regular Treatment ) 53 Supply Of Bionil 9030 ( Regular Treatment ) 54 Supply Of Ph Reducing Acid ( H2so4 ) 55 Supply Of Sodium Hypochlorite ( Liquid ) For Stp. 56 Supply Of Polyaluminum Chloride ( Pac ) ( Powder ) For Stp. 57 Supply Of Aluminim Sulphate ( Alum ) Powder For Stp. 58 Supply Of Blower Greece ( Grade - Ap 3 Greece ) Of Etp ( Effluent Treatment Plant ) Blowers. Make Of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3 / Hr. ( Make - Any ) 59 Supply Of Lubrication Gear Oil ( Grade - Ep 90 Gear Oil ) Of Etp ( Effluent Treatment Plant ) Blowers. Make Of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3 / Hr. ( Make - Any ) 60 Charges Towards 100 Hp Motor Preventive Servicing ( Cleaning Of Coil, Repainting Completely, Greasing And Etc. ) , The Work Should Be Done On Site Only. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 61 Charges Towards 75 Hp Motor Preventive Servicing ( Cleaning Of Coil, Repainting Completely, Greasing And Etc. ) , The Work Should Be Done On Site Only. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 62 Supply Of 100 Hp Motor Bearing Of Model No. Of Bearing 6316 2Z C3 80Mm I.D Plain Deep Groove Ball Bearing, 170Mm O.D ( Make - Skf ) . The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Skf ) 63 Supply Of 75 Hp Motor Bearing ( Model Of Bearing 6310 2Z C3 50Mm I.D Plain Deep Groove Ball Bearing, 110Mm O.D ( Make - Skf ) . The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transportation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Skf ) 64 Charges Towards Installation Of Bearings For 100 Hp And 75 Hp Water Pumps & Motors Wherever Applicable & Alignment Of Motor And Pumps. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 65 Supply Of 150 Bar Stihl Re 143 High Pressure Cleanersthe Ideal All-Rounder With Plus-Level Comfort. Hose Reel With 12 M Steel-Reinforced High-Pressure Hose, Flat Textile Hose With Holder, Brass Pump Head, Pressure / Flow Control, Pressure Gauge, Detergent Tank And Metering. Operating Pressure 10-140 Barmaximum Pressure 1 ) 150 Barmin. Water Throughput 540 L / Hmaximum Water Throughput 610 L / Hmax. Water Supply Temperature 60 °Cpower Output 2, 9 Kwmains Voltage 230 / 1- / 50 V / Hzpower Cable Length 5 Mweight 2 ) 27, 2 Kgsound Pressure Level 3 ) 76, 9 Db ( A ) Sound Power Level 3 ) 90 Db ( A ) Vibration Level 4 ) Fewer 2, 5 M / S²high-Pressure Hose Length 12 Mtransparent Detergent Tank 2, 0 L ( Make - Stihl / Equivalent ) 66 Rewinding Of Electric Motor Of Capacity 100 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 67 Rewinding Of Electric Motor Of Capacity 75 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 68 Rewinding Of Electric Motor Of Capacity 25 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 69 Rewinding Of Electric Motor Of Capacity 20 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 70 Rewinding Of Electric Motor Of Capacity 15 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 71 Rewinding Of Electric Motor Of Capacity 10 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 72 Rewinding Of Electric Motor Of Capacity 7.5 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 73 Rewinding Of Electric Motor Of Capacity 5 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 74 Rewinding Of Electric Motor Of Capacity 2 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 75 Rewinding Of Electric Motor Of Capacity 1 Hp.The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 76 Rubber Bellows - 200 Mm Diasupply, Installing, Testing And Commissioning Ofpn 16 Rating Flexible Pipe Connections ( Expansion Bellows ) With Connecting Rod, In Position Complete With Flanges, Bolts, Nuts, Including Gaskets Etc.Conforming To Specifications. ( Make - Any ) 77 Rubber Bellows - 250 Mm Diasupply, Installing, Testing And Commissioning Ofpn 16 Rating Flexible Pipe Connections ( Expansion Bellows ) With Connecting Rod, In Position Complete With Flanges, Bolts, Nuts, Including Gaskets Etc.Conforming To Specifications. ( Make - Any ) 78 Supply Installation Testing And Commissioning Of Valve Package Of Pipe Size 25 Mm Dia With Pibcv Valve Station Along With Thermostat And Sensors, Wiring, Control Wiring In Conduit From Valve To Air Condition Unit Controller. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transpotation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. ( Make - Siemens / Honeywell / Danfoss / Cruise / 79 Butterfly Valves :- 250 Mm Dia- Insulation Indoor Duty Supply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 80 Manual Butterfly Valves - 200 Mm Dia. - Valves With Insulationsupplying, Fixing, Testing And Commissioning Of Following Valves, Strainers, Gauges In The Chilled Water Plumbing Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 81 Manual Butterfly Valves - 150 Mm Dia. - Valves With Insulationsupplying, Fixing, Testing And Commissioning Of Following Valves, Strainers, Gauges In The Chilled Water Plumbing Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 82 Butterfly Valves :- 125 Mm Dia- Insulation Indoor Duty Supply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 83 Butterfly Valves :- 100 Mm Dia- Insulation Indoor Duty Supply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 84 Butterfly Valves :- 80 Mm Dia- Insulation Indoor Dutysupply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Valves Shall Be Pn-10 Rating, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 85 Butterfly Valves :- 65 Mm Dia- Insulation Indoor Dutysupply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 86 Butterfly Valves :- 50 Mm Dia- Insulation Indoor Dutysupply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 87 Butterfly Valves :- 40 Mm Dia- Insulation Indoor Dutysupply, Fixing, Testing And Commissioning Of Followingvalves, Strainers, Gauges In The Chilled Water Piping Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specification. Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring, Matching Flanges, Nuts & Bolts Pn 16 Pressure Rating For Chilled Water / Hot Water Circulation As Specified, The Quoted Rate Inclusive Of Matching Flanges, Nuts And Bolts Etc. ( Make - Honeywell / Audco / Intervalve / Advance ) 88 Nrv Valve 100 Mm Dia- Non - Return Valve With Duel Plate Of C I Body Ss Plates Vulcanized Nbr Seal Flanged End & Pn 16 Pressure Rating For Chilled / Hot Water Circulation Including Insulation As Specified. ( Make - Honeywell / Audco / Intervalve / Advance ) 89 Nrv Valve 125 Mm Dia- Non - Return Valve With Duel Plate Of C I Body Ss Plates Vulcanized Nbr Seal Flanged End & Pn 16 Pressure Rating For Chilled / Hot Water Circulation Including Insulation As Specified. ( Make - Honeywell / Audco / Intervalve / Advance ) 90 Nrv Valve 200 Mm Dia - Non - Return Valve With Duel Plate Of C I Body Ss Plates Vulcanized Nbr Seal Flanged End & Pn 16 Pressure Rating For Chilled / Hot Water Circulation Including Insulation As Specified. ( Make - Honeywell / Audco / Intervalve / Advance ) 91 Nrv Valve 250 Mm Dia - Supply Of Dual Plate Type Non Return Valve - Pn-16 Ratings For Water Lines. The Body Is Made Of Cast Iron / Stainless Steel, The Operating Temperature Is Between 0 To 90 Degree Celsius And The Pressure Is Around 16 Bar, Of Following Sizes. Location:-Chiller Pumps And Chiller ( Inlet & Outlet ) ( Make - Honeywell / Audco / Intervalve / Advance ) 92 Ball Valve 1 / 2 Inch Diameter- Supply & Installation Of Brass Type Ball Valve. All Complete As Per Specifications Of Following Sizes. ( Make - Rb / Leader / Audco ) 93 Ball Valve 1 Inch Diameter- Supply & Installation Of Brass Type Ball Valve. All Complete As Per Specifications Of Following Sizes. ( Make - Rb / Leader / Audco ) 94 Ball Valve 40 Mm Diameter- Supply & Installation Of Brass Type Ball Valve. All Complete As Per Specifications Of Following Sizes. ( Make - Rb / Leader / Audco ) 95 Supply And Installation Of Compressor ( Including Nitrogen Leak Test, Vacuum And Gas Charging ) , The Capacity Of The Refrigerator Is 1200 Liters. 96 Gas Charging ( Including Nitrogen Leak Test, Vacuum And Gas Charging ) , The Capacity Of The Refrigerator Is 1200 Liters. 97 Supply And Installation Of Sub Zero Controller With Sensor For The Refrigerator, The Capacity Of The Refrigerator Is 1200 Liters. 98 Supply And Installation Of Stainless Steel Door Of Refrigerator Of Capacity 1.2 Kl ( The Size Of The Door Is 500*500*25 Mm Thick. 99 Inline Fans - 600 Cfm / 10 Mm Spsupply Of Toilet Exhaust Ducted Inline Fans Of 10 Mm Static Presuure Of Water Column. The Capacity Of Fans Are Min 600 Cfm. The Body Is Made Of Ms. The Fan Is Compleyetly Single Phase And Not More Than 200 Watts. 100 Axial Type Fanssuppy And Installation Axial Type Exhaust Fans Details Of Requirement Are1 ) Sweep Size - 200 Mm2 ) No Of Blades - 3 / 4 / 5 Nos. Any Of Three3 ) Motor Speed - Normal Speed At About 1400 Rpmbody And Blades - Metallicair Delivery - 480 Cfmnoise Level - 40Db To 50 Dbmax Power Consuption-40 Watts / 230Volts / 50 Hz 101 Axial Type Fanssuppy And Installation Axial Type Exhaust Fans Details Of Requirement Are1 ) Sweep Size - 300 Mm2 ) No Of Blades - 3 / 4 / 5 Nos. Any Of Three3 ) Motor Speed - Normal Speed At About 1400 Rpmbody And Blades - Metallicair Delivery - 800 Cfmnoise Level - 50Db To 61 Dbpower Consuption - 50 Watts / 230Volts / 50 Hz 102 Supply And Installation Of High Flow 400 Mm Diameter Swipe Wall Mounted 3 Pvc Blades 3 Speed Controll Fans. Watt – 50-60 Frequency 50Hz. ( Make : Crompton Greaves / Havells / Usha ) 103 Supply And Installation Of High Flow 400 Mm Diameter Swipe Floor Stand Of Min Hieght 1 Meter From The Ground Mounted 3 Pvc Blades 3 Speed Controll Fans. Watt – 50-60 Frequency 50Hz. ( Make : Crompton Greaves / Havells / Usha ) 104 Sheet Metal Works :- 0-750 -------0.63 Mm ( 24G ) With Flangessupply, Installation, Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular / Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. 105 Sheet Metal Works :- 751-1500------0.80 Mm ( 22G ) With Ms Flangessupply, Installation, Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular / Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. 106 Insulation On Existing Chilled Water Pipe-32 Mm Thicksupplying, Laying, Fixing, Testing And Commissioning Of Followingthickness Closed Cell Elastrometric Nitrile Rubber Of Class O Appliedby Suiatable Adhesive , As Per Specifications And As Requiredcomplete In All Respect. 107 Insulation On Existing Chilled Water Pipe-19 Mm Thicksupplying, Laying, Fixing, Testing And Commissioning Of Followingthickness Closed Cell Elastrometric Nitrile Rubber Of Class O Appliedby Suiatable Adhesive , As Per Specifications And As Requiredcomplete In All Respect. 108 Insulation On Existing Chilled Water Pipe-11 Mm Thicksupplying, Laying, Fixing, Testing And Commissioning Of Followingthickness Closed Cell Elastrometric Nitrile Rubber Of Class O Appliedby Suiatable Adhesive , As Per Specifications And As Requiredcomplete In All Respect. 109 Duct Thermal Insulation :- 19 Mm Thicksupplying And Fixing Of Following Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber ( Class O ) Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required. 110 Supply Of Capacitor Application-General Purpose.Dielectric Characteristic-C0g / Np0.Tolerance- 5%.Capacitence - 40-50 Micro Fared.Frequency-50Hz Mpssh.Operating Temperature-Max 125 Degree C.Operating Temperature-Min 44 Degree C.Operating Temperature Range--40 Degree C To +85 Degree C 111 Supply Of Aluminium Tapes For Wrapping On The Hvac Pipe Lines For Avoiding The Air Leakage ( Size – 50Mmx40 Mtr ) 112 Supply And Installation Of Pressure Gauges Of Dial Size 100 Mm Diameter 10 Kg / Cm², For The Measurement Of Fluid Liquidsthat Are Non Highly Viscous, High Temp ( 60 Degree Celsius ) , The Outer Diameter Of The Threads Will Be 15 Mm 113 Supply And Installation Of Pressure Gauges Of Dial Size100 Mm Diameter 10 Kg / Cm², For The Measurement Of Fluid Liquidsthat Are Non Highly Viscous, High Temp ( 60 Degree Celsius ) , The Outer Diameter Of The Threads Will Be 12 Mm 114 Servicing Of Kitchen Hoods With Suitable Chemicals, Brushes Etc. The Hood Was Loaded With Dirty Oil, Dust And Carbondeposit On The Walls Of The Hoods. The Hood Is Made Up Ofstainless Steel 304 Grade. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transportation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 115 Servicing Of Scrubbers, Pumps, Motors. And Blowers And Entire Ahu Unit. The Scrubber Is Loaded With Dirty Oil, Dust And Carbondeposit On The Walls Of The Ahu Unit. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transportation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 116 Servicing Of Kitchen Hood Exhaust Ducting With Suitable Chemicals, Brushes Etc. The Ducting Was Loaded With Dirty Oil, Dust And Carbondeposit On The Walls Of The Hoods. The Hood Is Made Up Ofstainless Steel 304 Grade. The Quoted Rates Shall Be Inclusive Of All Taxes And Levis, Duties, Lead, Lift, Transportation, Placing, Scaffolding, Core Cutting Of Required Diameter In Walls, Finishing And Minor Civil Works And Nothing Shall Be Paid Separately. 117 Supply Of Non Iodized Salt ( Iodine Free ) Salt In Powder Form For Water Treatment Plant. 118 Flange Size - 610*610*150 And Box Size - 560*560*150 ( Flow Min - 2000 Cfm ) Supply & Installation Of Pre Filters For The Following Specifications, The Filters Of Grade Eu-K Or Eu4 With Efficiency Of 90% Down To 10 Microns, & It Should Be Aluminum Box Type With A Maximum Pressure Drop Of 5.0 Mm Of Water Gauge, The Aluminium Frame Of Minimum 25 Mm Thick.The Size Of Filters Are As Follows. 119 Flange Size - 610*305*150 And Box Size - 560*255*150 ( Flow Min - 1000 Cfm ) Supply & Installation Of Pre Filters For The Following Specifications, The Filters Of Grade Eu-K Or Eu4 With Efficiency Of 90% Down To 10 Microns, & It Should Be Aluminum Box Type With A Maximum Pressure Drop Of 5.0 Mm Of Water Gauge, The Aluminium Frame Of Minimum 25 Mm Thick.The Size Of Filters Are As Follows. 120 Flange Size - 610*610*150 And Box Size - 560*560*150 ( Flow Min - 2000 Cfm ) Supply & Installation Of Fine Filters For The Following Specifications, The Filters Of Grade Eu-K Or Eu6 With Efficiency Of 99% Down To 5 Micron, & It Should Be Aluminum Box Type With A Maximum Pressure Drop Of 6.33 Mm Of Water Gauge, The Aluminium Frame Of Minimum 25 Mm Thick.The Size Of Filters Are As Follows. 121 Flange Size - 610*305*150 And Box Size - 560*255*150 ( Flow Min - 1000 Cfm ) Supply & Installation Of Fine Filters For The Following Specifications, The Filters Of Grade Eu-K Or Eu6 With Efficiency Of 99% Down To 5 Micron, & It Should Be Aluminum Box Type With A Maximum Pressure Drop Of 6.33 Mm Of Water Gauge, The Aluminium Frame Of Minimum 25 Mm Thick.The Size Of Filters Are As Follows. 122 Flange Size - 610*610*300 And Box Size - 570*570*300 ( Flow Min - 2000 Cfm ) Supply & Installation Of Hepa Filters For The Following Specifications, The Section Shall Be Normally Designed For Deep Folded Disposable Synthetic Prefilters For Class Eu13 With Efficiency Of 99.99 % Down To 0.3 Micron, The Filter Should Be Aluminum Anodized Flange Typewith A Maximum Pressure Drop Of 33 Mm Of Wgthe Size Of Filters Are As Follows. 123 Flange Size - 610*305*300 And Box Size - 570*265*300 ( Flow Min - 1000 Cfm ) Supply & Installation Of Hepa Filters For The Following Specifications, The Section Shall Be Normally Designed For Deep Folded Disposable Synthetic Prefilters For Class Eu13 With Efficiency Of 99.99 % Down To 0.3 Micron, The Filter Should Be Aluminum Anodized Flange Typewith A Maximum Pressure Drop Of 33 Mm Of Wgthe Size Of Filters Are As Follows. 124 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 20 125 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 22 126 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 27 127 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 28 128 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 29 129 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 31 130 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 32 131 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 33 132 Supply& Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 34 133 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 36 134 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 37 135 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 38 136 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 41 137 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 42 138 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 44 139 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 45 140 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 46 141 Supply & Installationof V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 47 142 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 48 143 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 54 144 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 61 145 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 66 146 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 72 147 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 73 148 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - A 86 149 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 24 150 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 28 151 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 30 152 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 31 153 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 32 154 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 34 155 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 35 156 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 36 157 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 40 158 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 42 159 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 47 160 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 52 161 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 62 162 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 65 163 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 72 164 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - B 80 165 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spa 3000 166 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spa 3550 167 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spa 3750 168 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spa 4500 169 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spb 1500 170 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spb 1850 171 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spb 2060 172 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spb 2300 173 Supply & Installation Of V-Type Belts For AhuS Of The Following Model Nos. And Sizes. ( Make:Fenner / Poly F Plus / Ecodrive ) - Model No. - Spb 2430 174 Supply Installation Testing And Commissioning Of Vfd For Chilled Water Primary Pump Of Capacity 75 Kw / 1255 Usgpm / 54 M Head, For Primary Pumps ( Ip55 Mounted On Wall ) . 175 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting Fixing In Position And Applying Priming Coatof Approved Steel Primer All Completed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-09-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-09-2023

Key Value

Document Fees
INR 1180 /-
EMD
INR 204000.0 /-
Tender Value
INR 1.02 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail