Tender For Budgetary Offers Of Ex-Works Rates For Supplying Of Various Switchyard Equipments & Associated Accessories At Jigaon Lift Irrigation Scheme Dist. Buldana -1 Power Transformer 33000 / 433 Volt 160 KVA and other Specification Providing, erecting and commissioning out door type copper wound transformer as per IS 1180 (Part I) : 2014 Level I continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45º C by thermometer in oil and 50ºC by the resistance in winding after continuous run resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY 11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushings / cable end box on HT side and cable end box on LT side. 2 Nos. channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. transformer shall be of latest manufacturing standards as per amended IS specifications and the Load & No Load losses shall be as per IS. With Off Load Tap changer -12.5% to + 2.5% in steps of 2.5% 2 33 KV Transformer Control & Relay Panel without differential relay 3 Isolator without EB 2000Amp, 145 kV, 3 Phase, 50 HZ, 40 kA, BIL 650 kVp, outdoor, Horizontal centre break type isolator and Horizontal Centre rotating Double Break type isolator shall be gang operated through motor from local as well as from remote control panel. There should be provision for mechanical operation by hand of isolator locally. 4 Single phase, 145 kV, 800-400/1Amp 5 core, burden 20 VA, 50 HZ, 40 kA/sec, BIL 650 kVp, outdoor with Hermetically Sealed for line circuit breaker complete with accuracy class Core 1‐0.2 and other cores-4- PS ,with all other necessary accessories. 5 Single phase, 145 kV, 2400-1200/1Amp 5 core, burden 20VA, 50 HZ, 40 kA/sec, BIL 650 kVp, outdoor with Hermetically Sealed for line circuit breaker complete with accuracy class Core 1‐0.2 and other cores 4-PS ,with all other necessary accessories. 6 Single phase 36 kV, 1600-800/1-1-1-1 Amp, 20 VA, 50 HZ, 40 kA/sec, BIL 170 kVp, outdoor Hermetically Sealed, 4 core current transformer for line circuit breaker complete with accuracy class Core 1‐0.2 and other cores 3-PS ,with all other necessary accessories. 7 132 kV class potential transformer (P.T) etc. complete with all leads and lifts with contractors own material. 132kV/v3/110 V /v3/110 V /v3/110 V /v3 8 Single phase Metering Current Transformer with 145 kV, 200/1Amp, 0.2S class 1 core, burden 15VA as per MSEDCL/MSETCL specification 9 Single phase Metering Current Transformer with 145 kV, 50/1Amp, 0.2S class 1 core, burden 15VA as per MSEDCL/MSETCL specification 10 Single phase Metering Potential Transformer with 132kV/v3/110V/v3, burden 50VA, 0.2 class, 1 core, as per MSEDCL/MSETCL specification 11 ABT 4 Quadrant Import/Export type, --- /1 amp, class 0.2S, PTR-11000/v3/110/v3, KVAH, compliant meter as per MSEDCL specification 12 MFM ABT metering arrangment, 4 Quadrant Reactive energy along with AMR with integration to SLDC Airoli as per MSETCL Specification 13 100 KV Metering Cubical for ABT Meter ( For MSEDCL) 14 3Ø 4W 1A 0.2 CL Interface Energy Meter (AMR Meter) 15 IEM Panel with Accessaries 16 Preparation of PTCC route approval Proposal of 132 kV Transmission line and approval from the Divisional Engineer,Telegraph (PTCC), Mumbai and charging permission from the concern telecom, railway, defence authority and other department etc. as applicable 17 XLPE insulated, galvanised steel formed wire armoured (round) cable 33 kV(E), 3 C x 120 sq. mm. copper conductor laid in provided trench / pipe 18 XLPE insulated, galvanised steel formed wire armoured (round) cable 33 kV(E), 1C x 1000 sq. mm. copper conductor laid in provided trench / pipe 19 Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E) /33 kV (UE)XLPE HT cable 1C x 1000 sq. mm. with necessary material 20 Galvanised steel structure required for Gantry Towers station for L.A. Isolator with EB & without EB, CT, PT, PI alongwith Hardware such as nut bolts, washers, foundation bolts etc. complete. 21 220V, VRLA maintenance free battery, 300Ah, 110 cells etc. complete with all lead & lift 22 220V, battery charger, 20/30Amp, Float & boost along with DCDB etc. complete. 23 48 V battery 200 AH, VRLA, 24 Cells 24 48 V, 50 A, Float cum Boost charger (Micro Controller based) alongwith DCDB 25 ACDB 440V, 2-incomer & B/S interlocked (A) type 26 132kV Single bus Configuration Bus Bar material, ACSR conductor, suspension, tension/support insulator hardware, power connector, clamp etc. complete. 27 132kV Main + Transfer bus Configuration Bus Bar material, ACSR conductor, suspension, tension/support insulator hardware, power connector, clamp etc. complete. 28 SCADA - Substation atomation system for supervisory control & data acqursition of 132 kV switchyard. SAS shall also include accessories such as GPS clock, invertor, remotegateways for LDC, furniture etc. as per MSETCL specification. 29 SCADA for Remote end control and VSAT for prviding connectivity from Proposed Substation to MSETCL DC (Data Concentrator) with necessary configuration required for visibility of data at MSETCL SLDC/ALDC location under rental model for both way of transfer of data between remote substation and SLDC/ALDC control center. 30 145KV, 4KN Bus post insulator for conductor support. 31 33kV fuse element, with outdoor type with insulator completely erected on provided cross arm, each set comprising 3 units of 5/10 Amp 32 132kV Transfer Bus Coupler Control & Relay Panels Feeder Protection Scheme suitable for 2 BUS system having Numerical Protection Relay compliance to IEC61850 protocol as per MSETCL specification. 33 132kV, Numirical Bus Sectionaliser Control & Relay Panels as per MSETCL specification. 34 132 kV numerical feeder Control relay panel with BCU for metering Bay 35 132kV, Incoming line (Feeder) Numerical Control & Relay panel etc. complete. 36 132 kV , Numerical Busbar Protection Panel suitable for 10 circuite including 2 TBC & 1 Bus sectionaliser ( main + 1 transfer bus arrangment) as per MSETCL specification. 37 33 kV Feeder control & relay panel, Line feeder panel with Numerical type as per MSETCL standard technical specification. 38 33 Feeder control & relay panel, double feeder panel with Numerical type as per MSETCL standard technical specification. 39 33kV Bus Sectionaliser Control & Relay Panels Feeder Protection Scheme suitable for 2 BUS system having Numerical Protection Relay compliance to IEC61850 protocol as per MSETCL specification. 40 Power Transformer 33000 / 433 Volt 200 KVA and other Specification as per Providing, erecting and commissioning out door type copper wound transformer as per IS 1180 (Part I) : 2014 Level I continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45º C by thermometer in oil and 50ºC by the resistance in winding after continuous run resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY 11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushings / cable end box on HT side and cable end box on LT side. 2 Nos. channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. transformer shall be of latest manufacturing standards as per amended IS specifications and the Load & No Load losses shall be as per IS. With Off Load Tap changer -12.5% to + 2.5% in steps of 2.5% 41 Preparation of 132/33 kV Switchyard Plan Layout, Single Line Diagram & Sectional Layout (printing 10 copies on A-2 Size Paper) as per approved scheme by MSETCL and MSEDCL. 42 Preparation of 33 kV line route map. 43 Double tension hardware (DTN) suitable for 0.2 ACSR Panther conductor. 44 Single tension hardware (STN) suitable for 0.2 ACSR Panther conductor. 45 Single Suspension hardware (SSN) suitable for 0.2 ACSR Panther conductor. 46 Double suspension hardware (DSN) suitable for 0.2 ACSR Panther conductor. (1 arcing horn on line side & with 2 arcing horn on line side as well as tower side.) 47 Vibrasion damper for 0.2 ACSR Panther conductor. 48 PA rod (performed Armour) for 0.2 ACSR Panther conductor.49 Mid span joint for 0.2 ACSR Panther conductor. 50 Repair Sleeve for 0.2 ACSR Panther conductor. 51 Tower accessories of 132KV line i.e Danger Board, Number plate, Phase Plate (R,Y,,B), Circuit plate (C1. C2), Anti-climbing devices with Barbed wire., Bird Guard etc. 52 0.2 Panther ACSR, conductor 53 36kV Rated voltage, 3 Ph, 50 Hz, triple pole ,outdoor type ,SF6 Circuit Breaker, rated short circuit breaking current 25 kA for 3 sec., spring mechanism, breaker operation & protection circuit with 110VDC, with supporting structure & necessary equipment etc complete for rated normal current of