Real Time Energy Management System ( Ems ) To Monitor Critical Electrical Equipment Of Pump Stations And Power Consumption Of All Stations In Srpl-Gst % For The Tender Please Select The Rate Of Gst In Cell Ay13. Rate Selected Shall Be Applicable For The Entire Boq. 2 Centralized Ems Req. Chennai Ps 3 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 4 Complete Software Integration - One Time Engineering, Installation & Commissioning Charges For Software On-Boarding, Hardware Configuration, Account Setup Or Any Other Charges.Remarks- 1.For 30 Gateways ( Dcus ) , 185 Meters / Vfds / Process Controllers 5 Software Cost With Lifetime License Including Defect Liability Period Of 12 Months. Remarks- 1. For Server As Well As Clients, Lump Sum. 2.There Shall Be 2 User Credentials For Each Location And 3 User Credentials At Chennai Ps 3. Software Shall Include Compliancetolatestiso Standard, Cyber Security Standard ( Latest Edition ) And 100% Complaint To It Policy. 6 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 7 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Storage With Time Stamp, Field Programmable, Class 0.5, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol 8 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 9 Supply And Laying Of Lan Cat Vi Cable Including Termination . 10 Module Interface Communication: Serial Interface Communication Module 11 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 12 Centralized Server With Intel Core I9 Processor, 1Tb Hdd + 512 Gb Ssd, 16 Gb Ram With Fhd Led 22-24 Inch Monitor With Suitable Os 13 Boq At Srpl Chengalpet For Ems 14 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 15 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 16 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 17 Supply And Laying Of Lan Cat Vi Cable Including Termination . 18 Module Interface Communication: Serial Interface Communication Module 19 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 20 Boq At Srpl Asanur For Ems 21 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 22 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 23 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 24 Supply And Laying Of Lan Cat Vi Cable Including Termination . 25 Module Interface Communication: Serial Interface Communication Module 26 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 27 Boq At Srpl Trichy For Ems 28 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 29 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 30 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 31 Supply And Laying Of Lan Cat Vi Cable Including Termination . 32 Module Interface Communication: Serial Interface Communication Module 33 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 34 Boq At Srpl Chittoor For Ems 35 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 36 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 37 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 38 Supply And Laying Of Lan Cat Vi Cable Including Termination . 39 Module Interface Communication: Serial Interface Communication Module 40 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 41 Boq At Srpl Bengaluru For Ems 42 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 43 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 44 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Storage With Time Stamp, Field Programmable, Class 0.5, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol 45 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 46 Supply And Laying Of Lan Cat Vi Cable Including Termination . 47 Module Interface Communication: Serial Interface Communication Module 48 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 49 Boq At Srpl Madurai For Ems 50 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 51 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 52 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Storage With Time Stamp, Field Programmable, Class 0.5, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol 53 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 54 Supply And Laying Of Lan Cat Vi Cable Including Termination . 55 Module Interface Communication: Serial Interface Communication Module 56 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 57 Boq At Srpl Sankari For Ems 58 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 59 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 60 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Storage With Time Stamp, Field Programmable, Class 0.5, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol 61 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 62 Supply And Laying Of Lan Cat Vi Cable Including Termination . 63 Module Interface Communication: Serial Interface Communication Module 64 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 65 Boq At Srpl Ennore For Ems 66 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 67 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 68 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Storage With Time Stamp, Field Programmable, Class 0.5, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol 69 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 70 Supply And Laying Of Lan Cat Vi Cable Including Termination . 71 Module Interface Communication: Serial Interface Communication Module 72 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 73 Boq At Srpl Ramanathapuram For Ems 74 Supply And Installation Of Iot Energy Gateway Communication Module With Memory Facility Including At Locations Mentioned In Scope Of Work 75 Supply And Laying Of 2Cx1.5 Sq.Mm Multi Stranded Copper Conductors Cable, Twisted, Shielded, Frls Sheathed, Flexible Armoured Control Cables With Generally As Specified Andshall Include The Terminations . 76 Supply And Laying Of Lan Cat Vi Cable Including Termination . 77 Module Interface Communication: Serial Interface Communication Module 78 Plc System Modification:Manday Basis Modification Work / Troubleshooting Wrok In Plc System Logic / Scc Hmi Screens Etc. 79 Supply , Installation, Testing And Commissioning Ofmeter Having, True Rm, Simultaneous Samplingof Volts & Amps, High Low Recordingof Vll & Vln, V, A, Hz, W, Va, Pf, Var Value, Harmonics Individual And Total, Maximum Demand, Time Of Use Etc Storage With Time Stamp, Field Programmable, Class 0.2, Rs 485 Series Channel Connection, Industry Standard Modbus, Modbus Rtu Protocol. 80 Complete Software Annual Maintenance Con 81 Complete Software Annual Maintenance Contract And Upgradation For 2Nd To 5Th Year. Which Implies Quick Response And Rectification Of Any Trouble In Software During Amc Period Occurring Due To Any Kind Of Problem In Software As Well As Hardware.