Tender For Maintenance Of Underground System= 1 1.1Kv Lt Armoured Powercable 3.5X240sqmm 2 1.1Kv Lt Armoured Powercable 3.5X150sqmm 3 Lt Service Cable From Db To Meter: 1.1Kv Lt Xlpecable 3.5X70sqmm 4 Lt Service Cable From Db To Meter: 1.1Kv Lt Xlpecable 4X25sqmm 5 Lt Service Cable From Db To Meter: 1.1Kv Lt Pvccable 4X16sqmm 6 Lt Service Cable From Db To Meter: 1.1Kv Lt Pvccable 4X10sqmm 7 1.1Kv Lt Armoured Powercable 2X10sqmm 8 Supply Of Lt Cable Heavy Duty Double Compression Termination Brass Glands And Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 9 Supply Of Lt Cable Heavy Duty Double Compression Termination Brass Glands 10 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X400sqmm 11 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X240sqmm 12 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X150sqmm 13 1.1Kv Lt Xlpe Cable 4X25sqmm 14 1.1Kv Lt Xlpe Cable 4X10sqmm 15 1.1Kv Lt Xlpe Cable2x10sqmm 16 1.1Kv Lt Xlpe Cable2x6sqmm 17 Supply Of Lt Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 18 Al Lugfor 1.1Kv Lt Xlpe Cable 3.5X400sqmm 19 Al Lug For 1.1Kv Lt Xlpe Cable 3.5X240sqmm 20 Al Lug For 1.1Kv Lt Xlpe Cable 3.5X150sqmm 21 1.1Kv Lt Xlpe Cable 4X25sqmm 22 1.1Kv Lt Xlpe Cable 4X10sqmm 23 1.1Kv Lt Xlpe Cable2x10sqmm 24 1.1Kv Lt Xlpe Cable2x6sqmm 25 Supply Of Smart Street Light Management System With Box, 10-60 Amp. As Per Specifications Complete Set 26 Street Light Management Timer Switch Along With Energy Meter As Per Already Approved Gtp 27 Mcb 63 Amp For Street Light Management Box Double Pole Havells Or Above Quality 28 Supply Of 33 Kv Ring Type Metering Ct 600-300 / 1, Cl0.5 For 33 Kv Rmu 29 Supply Of 33 Kv Ring Type Protection Ct 600-300 / 1, 5P10 For 33 Kv Rmu 30 Supply Of 33 Kv Pt 33Kv / 110Voltfor 33 Kv Rmu 31 Supply Of 11 Kv Ring Type Metering Ct 400-200-100 / 1, Cl 0.5 For 11 Kv Rmu 32 Supply Of 11 Kv Ring Type Protection Ct 400-200-100 / 1, 5P10 For 11 Kv Rmu 33 Supply Of 11 Kv Pt 11Kv / 110Volt For 11 Kv Rmu 34 Supply Of Air Circuit Breaker, 50 Ka, 4 Pole Fixed Manual Type, Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-2000 Ampere ( Abb ) As Per Approved Gtp For Css 35 Supply Of Mccb, 4P 50 Ka Fixed Manual Type Microprocessor Based Release With O / C, E / F & S / C Protection-400 Ampere ( Abb ) As Per Approved Gtp For Css 36 Supply Of Mccb, 4P 50 Ka Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-250 Ampere ( L&T, Havells, Abb ) As Per Incoming In Lt Distribution Box 37 Supply Of 400Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Incoming & Outgoing ( L&T, Havells, Abb ) 38 Supply Of 100Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) 39 Supply Of 63 Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) 40 Supply Of Series Trip, Self-Powered Microprocessor Based Numerical Over Current Relay ( Idmtl + Inst. ) . O / C For Css ( Ashida Make ) 41 Supply, Ofal Bus Bar Of L.T C Pannelof Size50x5mmfor 3Phase + N, Off Standard Size. 42 Supply Of Ht Cable Termination Kits / Straight Through 43 33 Kv ( E ) Xlpe Ht Cable J / Ktype 3 X 400 Sq.Mm ( O / D ) Type ( Make Raychem 3M ) 44 33Kv ( E ) Xlpe Ht Cable 3X400sqmm ( Straight Thro ) ( Make Raychem 3M ) 45 33Kv Touch Proof Termination Kits 3X400sq Mm ( I / D ) Type ( Suitable For 33Kv ( Rmu ) ( Make Raychem 3M ) 46 33 Kv ( E ) Xlpe Ht Cable J / K 1 X 630 Sq.Mm ( Outdoor ) ( Make Raychem 3M ) 47 33Kv ( E ) Xlpe Ht Cable J / K1x630sqmm ( Straight Thro ) ( Make Raychem / 3M ) ) 48 33Kv Touch Proof Termination Indoor Kits 1X630sq Mm ( Suitable For 33Kv ( Rmu ) ( Raychem / 3M ) 49 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Indoor ) ( Raychem 3M ) 50 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Outdoor ) ( Raychem 3M ) 51 11Kv ( E ) Xlpe Ht Cable J / K3x300sqmm ( Straight Thro ) ( Raychem 3M ) ) 52 Supply Of Lt Cable Termination Kits / Straight Through 53 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X400sqmm 54 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X240sqmm 55 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X150sqmm 56 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X70sqmm 57 Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X50sqmm 58 1.1 Kv Cable Kit Size For Cable Of Size 4X16sqmm, 4X10 Sqmm / 2X10sq Mm / 2X6sq Mm Complete Set Including Mastic Tape Complete 59 Supply Of Hdpe Pipefor Laying 11Kv & L.T Cable 60 ( A ) 100Mm 61 ( B ) 75 Mm 62 ( C ) 50Mm 63 Supply Of Lt C Pannel 64 T-Connector For 11 Kv D / P 65 Mastic Tape 66 Flr 67 Wrsm Recron Sheet For Covering Minor Cuts In Cable 68 Supply Of Insulator For C Pannel Bus Bar 69 Total ( A ) 70 Erection Work 71 Routine Maintenance, Preventive Maintenance Of Complete Network Which Includes Routine Inspection Of All Equipments ( With Thermovision Camera Where Ever Applicable ) , All Kinds Of Panels, Transformers, All Types Of Overhead Structures, Tightening Of Joints / Lugs, Cable Health Monitoring, Maintaining Record / Log Book / Photos. As Per Direction & Shedule Provided By Officer In Charge. 72 ( A ) :-Digging Of Pit For Replacement Of Damage 33 Kvkit / Straight Thruoght& Removed Old Existing Damage J / K 73 ( B ) :-Digging Of Pit For Replacement Of Damage 11 Kv Kit / Straight Thruoght& Removed Old Existing Damage J / K 74 ( C ) :-Digging Of Pit For Replacement Of Damage 0.4Kvkit / Straight Thruoght& Removed Old Existing Damage J / K With Supply 75 ( A ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( 33Kv And Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 76 ( B ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( 11Kvand Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 77 ( C ) :-.Back Fillingof Pit By Earth &Stone After Filling Of Straight Through Of ( Lt ) And Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 78 C-Consumer S / C 79 ( A ) :-Digging Of Pit For Damage Consumer S / C 80 ( B ) Jointing Of Damage Consumer, S Cable ( Including Jointing Material ) 81 ( C ) :-.Back Filligof Pit After Jointing / Fixing Of Consumerservice Cableand Repairing Of Road Inclusing Cost Of Cement, Sand & Stone 82 Under Grounding Of All 33 Kv Lines And Other Related Works Under The Project Area 83 Jointing / Replacement Of Damage Or Burnt / Laying Of Ht Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 84 33Kv ( E ) Xlpe Ht Cable 3X400sqmm 85 33Kv ( E ) Xlpe Ht Cable 1X630sqmm 86 Replacement Of Damage Or Burnt / Laying Of Ht Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 87 11Kv ( E ) Xlpe Ht Cable 3X300sqmm 88 Erection, Testing, Replacement Of Damage Or Burnt And Commissioning Of Ht Cable Termination Kits / Straight Through 89 33 Kv ( E ) Xlpe Ht Cable 3 X 400 Sq.Mm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 90 33 Kv ( E ) Xlpe Ht Cable 1 X 630 Sq.Mm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work Including 91 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Outdoor ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work Including 92 33Kv Touch Proof Termination Kits 3X400sq Mm ( Suitable For 33Kv ( Rmu ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, 93 33Kv Touch Proof Termination Kits 1X630sq Mm ( Suitable For 33Kv ( Rmu ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, Duly Plumbing 94 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Indoor ) On Switchgears After Carefully Removing The Insulation Of The Cable, Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs, Duly Plumbing. 95 33Kv ( E ) Xlpe Ht Cable 3X400sqmm ( Straight Thro ) After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 96 33Kv ( E ) Xlpe Ht Cable 1X630sqmm ( Straight Thro ) Aftercarefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 97 11Kv ( E ) Xlpe Ht Cable 3X300sqmm ( Straight Thro ) Aftercarefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work 98 Repairing Of 33 / 11 Kv Rmu Door With Locking Arrangement & Gasket / Rubber Around The Panel Door.With Tightness Ofindoor Joints In 33 Kv / 11 Rmu & Css With Washers 99 Replacement Of Phase Indicators, With Supply 100 Replacement Of Phase Sensors With Supply 101 Rewiring / Repairing Of Internal Connection In 33 / 11 Kv Rmu & Css For Any Malfunctioning ( Supply Wire & Lugs ) 102 Refilling Of Sf6 Ges In 33 / 11 / Css Rmu Includinmgsf6 Ges Supply 103 Replacement / Errection Of Damaged Motor For Spring Charging For 33 / 11 Kv Rmu Including Supply And Fixing Abb Make 104 El Machanisam For Rmu Brakerincluding Supply Andfixing Abb Make 105 33 Kv Rmu Bushing ( 3 No. ) Including Supply Andfixing Abb Make 106 11 Kv Rmu Bushing ( 3 No. ) Including Supply Andfixing Abb Make 107 Tripping Coil 24 V Dc Including Supply Andfixing Abb Make 108 Closing Coil 24 V Dc Including Supply Andfixing Abb Make 109 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Of 33 / 11 Kv Ring Type Metering / Protection Ct For RmuS 110 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Of 33 / 11 Kv Pt For RmuS 111 Earthing For Dtr , Rmu, Css And Lt Feeder Panels 112 Installation / Replacement Of Chemical Earthing Station As Per Is 3043 Complete With Gi Earthing Electrode , Bentonite, . Conductor Upto Test Link, Test Link, Earthing Chamber, 450X450 Mm C.I. Manhole Chamber Etc. 113 Replacement Of Damage Or Burnt / Laying Of Al Conductor Pvc Insulated1.1 Kv Grade Armoured Lt Power Cable As Per The Code Of Practice For Installation And Maintenance Of Power Cables As Per Is 1255 :1983 Or Latest Amendments Through Manual Hdd Which Is As Good As Open Excavation. 114 1.1Kv Lt Armoured Powercable 3.5X400sqmm 115 1.1Kv Lt Armoured Powercable 3.5X240sqmm 116 1.1Kv Lt Armoured Powercable 3.5X150sqmm 117 Lt Service Cable From Db To Meter: 1.1Kv Lt Xlpecable 3.5X70sqmm 118 Lt Service Cable From Db To Meter: 1.1Kv Lt Xlpecable 4X25sqmm 119 Lt Service Cable From Db To Meter: 1.1Kv Lt Pvccable 4X16sqmm 120 Lt Service Cable From Db To Meter: 1.1Kv Lt Pvccable 4X10sqmm 121 Lt Service Cable From Db To Meter: 1.1Kv Lt Pvccable 2X6sqmm 122 1.1Kv Lt Armoured Powercable 2X10sqmm 123 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Lt Cable Heavy Duty Double Compression Termination Brass Glands 124 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X400sqmm 125 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X240sqmm 126 Brass Gland For 1.1Kv Lt Xlpe Cable 3.5X150sqmm 127 1.1Kv Lt Xlpe Cable 4X25sqmm 128 1.1Kv Lt Xlpe Cable 4X10sqmm 129 1.1Kv Lt Xlpe Cable2x10sqmm 130 1.1Kv Lt Xlpe Cable2x6sqmm 131 Errection Of Lt Long Barrel Heavy Duty Al Lugs Suitable For The Following Cable Sizes: 132 Al Lugfor 1.1Kv Lt Xlpe Cable 3.5X400sqmm 133 Al Lugfor 1.1Kv Lt Xlpe Cable 3.5X240sqmm 134 Al Lug For 1.1Kv Lt Xlpe Cable 3.5X150sqmm 135 1.1Kv Lt Xlpe Cable 4X25sqmm 136 1.1Kv Lt Xlpe Cable 4X10sqmm 137 1.1Kv Lt Xlpe Cable2x10sqmm 138 1.1Kv Lt Xlpe Cable2x6sqmm 139 Replacement Of Door With Hinges & Locking Arrangement In Lt C Type Distribution Boxes With Supply 140 Erection, Testing And Commissioning / Replacement Of Damage Or Burnt Smart Street Light Management System With Box, 10-60 Amp. As Per Specifications 141 Erection, Testing And Commissioning Of Air Circuit Breaker, 65 Ka, 4 Pole Fixed Manual Type, Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-2000 Ampere ( Abb ) As Per Approved Gtp For Css 142 Erection, Testing And Commissioning Of Mccb, 4P 36 Ka Fixed Manual Type Microprocessor Based Release With O / C, E / F & S / C Protection-400 Ampere ( Abb ) As Per Approved Gtp For Css 143 Erection, Testing And Commissioning Of Mccb, 4P 50 Ka Microprocessor Based Lsig Release With O / C, E / F & S / C Protection-250 Ampere ( L&T, Havells, Abb ) As Per Approved Gtp For Incoming In Lt Distribution Box 144 Erection, Testing And Commissioning Of 400Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Incoming & Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 145 Erection, Testing And Commissioning Of 100Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 146 Erection, Testing And Commissioning Of 63 Amps Tp Mccb 50Ka Tm Based O / C, S / C Release For Outgoing ( L&T, Havells, Abb ) As Per Approvedgtp 147 Erection, Testing And Commissioningseries Trip, Self-Powered Microprocessor Based Numerical Over Current Relay ( Idmtl + Inst. ) . O / C For Css ( Ashida Make ) As Per Approved Gtp 148 Checking Of Earth Strip With Welding Joints Are Smooth Painted With Anti Corrosion Paint Or Checking Of Suitable Size Nuts & Washer Used 149 Replacement Of Damage Busbar Of C Pannelincluding Disconnection / Reconnection Ofassociated Consumer 150 Repairing Of Existing Damagefencing 151 Reparing Of Damageequipmentplinth Including Material 152 Erection And Filling Of Lt J / Kit 153 Erection And Fillingheat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X400sqmm 154 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X240sqmm 155 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X150sqmm 156 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X70sqmm 157 Erection And Filling Heat Shrinkable 1.1Kv Xlpestraight Though J / Kit Size Of 3.5X50sqmm 158 1.1 Kv Cable Kit Size For Cable Of Size 4X16sqmm, 4X10 Sqmm / 2X10sq Mm / 2X6sq Mm Complete Set Including Mastic Tape Complete 159 Laying Of Hdpe Pipefor Laying 11Kv & L.T Cable 160 ( A ) 100Mm 161 ( B ) 75 Mm 162 ( C ) 50Mm 163 Erection Of Lt C Pannel With Making All Lt Connection 164 T-Connector For 11 Kv D / P 165 Total ( B ) 166 Total ( A+B ) 167 Company / Firm Name 168 Name 169 Designation 170 Date