Tender For Supply And Installation Of Ht Cable From Substation 4A To Substation 5 At Aiims Patna, patna-Bihar

All India Institute Of Medical Sciences has published Tender For Supply And Installation Of Ht Cable From Substation 4A To Substation 5 At Aiims Patna. Submission Date for this Tender is 22-08-2023. Bolts Tenders in patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

38953253
Tender For Supply And Installation Of Ht Cable From Substation 4A To Substation 5 At Aiims Patna
Open Tender
Indian
Bihar
Patna
22-08-2023

Tender Details

Tender For Supply And Installation Of Ht Cable From Substation 4A To Substation 5 At Aiims Patna ; 1 Supplying Of Under Ground Power Cable 3Core 300Sqmm Stranded Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Inuslation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cross Laid Up, Innersheath Of Pvc, Galvenised Steel Flat Strip Armoured & Overall Pvc Sheathed Cable Confirming To Is 7098 ( Part-2 ) 2011 With Upto Date Amendmets Suitable For 11Kv ( Make Havells Model Aluminium Conductor A2xfy / / Rr / Polycab Or Similar / Superior ) 2 Supplyingandinstallingfollowingsizeofperforatedpaintedwith Powder Coating M.S. Cable Trays With Perforation Not More Than17.5%, Inconvenientsections, Joinedwithconnectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 3 Layingandfixingofonenumberpvcinsulatedandpvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required.Above185sq.Mmandupto400 Sq.Mm ( Clampedwith 40X3mm Ms Flat Clamp ) 4 Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cmx50cmat Thetopwithathicknessof10cmincluding Inscription Duly Engraved As Required. 5 Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. 6 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Powercableof11kvgradeoffollowingsizedirect Inground Includingexcavation, Sandcushioning, Protectivecoveringand Refilling The Trench Etc As Required.Above 120 Sq. Mm And Upto 400 Sq. Mm 7 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 11 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. Above 120 Sq. Mm And Upto 400 Sq. Mm 8 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Powercableof11kvgradeoffollowingsizeintheexisting Masonry Open Duct As Required.Above 120 Sq. Mm And Upto 400 Sq. Mm 9 Supplyingandmakingindoorcableendterminationwithheat Shrinkablejointingkitcompletewithallaccessoriesincluding Lugssuitableforfollowingsizeof3core, Xlpealuminium Conductor Cable Of 11 Kv Grade As Required : 300 Sq Mm 10 Supplying And Making Outdoor Cable End Termination With Heat Shrinkablejointingkitcompletewithallaccessoriesincluding Lugssuitableforfollowingsizeof3core, Xlpealuminium Conductor Cable Of 11 Kv Grade As Required : 300 Sq Mm 11 Supplying And Making Straight Through Cable Jointing With Heat Shrinkablejointingkitcompletewithallaccessoriesincluding Ferrulessuitableforfollowingsizeof3core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required : 300 Sq. Mm 12 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Alongwithallaccessorieslikesocket, Bend, Couplersetc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation Andrefilling The Trenchbut Excludingsandcushioning And Protective Covering Etc., Complete As Required.160 Mm Dia ( Od-160 Mm & Id-135 Mm Nominal ) 13 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returningthe Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm 14 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 15 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mmnominal Size Derived From Natural Sources ) 16 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement -All Work Up To Plinth Level : 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 17 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 18 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 19 Half Brick Masonry With Common Burnt Clay F .P .S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 20 Finishing12 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) 21 Road Workdry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete :With Common Burnt Clay F .P .S. ( Non Modular ) Bricks Of Class Designation 7.5

Key Value

Document Fees
INR 1500 /-
EMD
INR 110348.0 /-
Tender Value
INR 55.17 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail