Supply Of Fabric Compensators For Ptps, Panipat-1 Boiler Spares Item Name:Fabric Compensator Size:L:8 Mtr W:250Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:110 Mw Additional Information: For Pa Rah, Working Temperature:400 Deg Celcius 2 Boiler Spares Item Name:Fabric Compensator Size:L:12 Mtr W:400Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:110 Mw Additional Information:For Sa Rah Outlet To Wind Box, Working Temperature:400 Deg Celcius 3 Boiler Spares Item Name:Fabric Compensator Size:L:20 Mtr, W:600Mm Assembly:Ducting Guide Vanes Equipment:Air Heater Make:Bhel Model:27 Vitm 1850 ( 2000 ) Capacity:210 Mw Additional Information:For Eco.Outlet, Working Temperature:350°C 4 Boiler Spares Item Name:Fabric Compensator Size:L:21 Mtr, W:300 Mm Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:For Secondary Air Rah Outlet, Working Temperature 350 Degree Celcius, Design Temp. 400 Deg. Celcius, Dust Concentration 50 Gm / Nm3 5 Boiler Spares Item Name:Fabric Compensator Size:L:17 Mtr, W:500 Mm Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:For Primary Air From Rah Outlet, Working Temperature:350°C, Design Temp.:400°C, Dust Concentration:50 Gm / Nm3, Pressure Rating:1000Mmwc 6 Boiler Spares Item Name:Fabric Compensator Size:L:13 Mtr, W:400 Mm Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:For Flue Gas Rah Outlet, Est Vertical, Working Temperature:350°C, Design Temp.:400°C, Dust Concentration:50Gm / Nm3 7 Boiler Spares Item Name:Fabric Compensator Size:L:26 Mtr, W:200 Mm Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:For For Rah Utlet, Size:3364X8470, Working Temperature:350°C, Design Temp.:400°C, Dust Concentration:50Gm / Nm3 8 Boiler Spares Item Name:Fabric Compensator Size:L:12 Mtr, W:300 Mm Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature: 350°C; Suitable For Hot Pa To Mil 9 Boiler Spares Item Name:Fabric Compensator Size:L:17Mtr, W:400 Mm Material:Silicon Coated Reinforcement With Treated Glass Fabric Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:Suitable For Rcej Of Flue Gas Duct From Rah To Esp Inlet Duct, Working Temperature= 350°C; Design Temp.=400 Deg. Celcius, Dust Concentration- 50Gm / Mm3, Pressure Rating: 1000Mmwc 10 Boiler Spares Item Name:Fabric Compensator Type:Multilayered Size:L:12Mtr, W:600 Mm Material:Silicon Coated Reinforcement With Treated Glass Fabric Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:Suitable For Rcej Of Hot Primary Air Duct From Rah To Mill , Working Temperature= 350°C; Design Temp.=400 Deg. Celcius, Dust Concentration- 50Gm / Mm3, Pressure Rating: 1000Mmwc 11 Boiler Spares Item Name:Fabric Compensator Type:Multilayered Size:L:14Mtr, W:500 Mm Material:Silicon Coated Reinforcement With Treated Glass Fabric Equipment:Ducts, Dampers, Gates Make:Bhel Model:Not Available Capacity:210 Mw Additional Information:Suitable For Rcej Of Secondary Air Duct From Rah To Wind Box Inlet , Working Temperature= 350°C; Design Temp.=400 Deg. Celcius, Dust Concentration- 50Gm / Mm3, Pressure Rating: 1000Mmwc 12 Boiler Spares Item Name:Fabric Compensator Size:L:18 Mtr, W:300 Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:300 Deg Celcius 13 Boiler Spares Item Name:Fabric Compensator Size:Length:27Mtr, Width:600 Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:350°C;Suitable For Eco Outlet In Flue Gas 14 Boiler Spares Item Name:Fabric Compensator Size:Length:31Mtr, Width:400Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:350°C;Suitable For Aph Inlet In Flue Gas 15 Boiler Spares Item Name:Fabric Compensator Size:Length:31Mtr, Width:300Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gn / Nm3, Working Temperature:200°C;Suitable For Aph Outlet In Flue Gas 16 Boiler Spares Item Name:Fabric Compensator Size:Length:22Mtr, Width:300Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:300°C; Suitable For Aph Outlet In Secondary Air 17 Boiler Spares Item Name:Fabric Compensator Size:Length:14Mtr, Width:300Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:300°C;Suitable For Secondary Air Interconnection 18 Boiler Spares Item Name:Fabric Compensator Size:Length:9.5Mtr, Width:300Mm Equipment:Ducts, Dampers, Gates Make:Not Available Model:Not Available Capacity:250 Mw Additional Information:Dust Concentration:50Gm / Nm3, Working Temperature:270°C;Suitable For Hot Pa To Mill