}

Tender For Provision Of Electrical Installations In Newly Constructed S. K. Shelter At M - Pkt Dhalao, Phool Wali Gali, Dilshad Garden In Ward No. 217, Under Shahdara ( North ) Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Provision Of Electrical Installations In Newly Constructed S. K. Shelter At M - Pkt Dhalao, Phool Wali Gali, Dilshad Garden In Ward No. 217, Under Shahdara ( North ) Zone.. Submission Date for this Tender is 08-08-2023. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38933149
Tender For Provision Of Electrical Installations In Newly Constructed S. K. Shelter At M - Pkt Dhalao, Phool Wali Gali, Dilshad Garden In Ward No. 217, Under Shahdara ( North ) Zone.
Open Tender
NCB
Delhi
Delhi
08-08-2023

Tender Details

Tender For Provision Of Electrical Installations In Newly Constructed S. K. Shelter At M - Pkt Dhalao, Phool Wali Gali, Dilshad Garden In Ward No. 217, Under Shahdara ( North ) Zone. 2 Od5232 / 2023-2024:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 3 Od5233 / 2023-2024:Supplying And Fixing 20 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 4 Od5234 / 2023-2024:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, 10 Ka C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. ( Single Pole ) 5 Od5235 / 2023-2024:Supplying And Fixing Extra Conduit Down Rod Of 20 Cm Length G.I. Pipe 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. ( Note : More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored ) 6 Od5236 / 2023-2024:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 7 Od5237 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required ( A ) 3 Pin 5 / 6 Amp Socket Outlet 8 Od5238 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required ( A ) 5 / 6 Amps Switch 9 Od5239 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. A. 2X 6 Sq.Mm + 1X 6 Sq.Mm Earth Wire 10 Od5240 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. A. 2X4 Sq.Mm + 1X4 Sq.Mm Earth Wire 11 Od5241 / 2023-2024:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. A. 2X2.5 Sq.Mm + 1X2.5 Sq.Mm Earth Wire 12 Od5242 / 2023-2024:Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 13 Od5243 / 2023-2024:Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 14 Od5244 / 2023-2024:Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal / Coke And Salt ) As Required 15 Od5245 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 16 122.1.2:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*6 Sqmm 17 122.1.47:Supply Of 250 Mm ( 10 Inch ) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutter Blades Etc. As Required. 18 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 19 122.2.27:Sitc Of 30W Led Flood Light Luminaire Fitted With Lens, Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =30 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 20 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 21 Od5272 / 2023-2024:Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) Ms Flat Clamp ) 22 Ar Items 23 2.3.2:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator8 Way, Double Door 24 2.12.2:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 25 2.14.1:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps

Key Value

Document Fees
INR 590 /-
EMD
INR 1514.0 /-
Tender Value
INR 74870.0 /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail