}

Tender For Periodical Services To Smq Md Accommodation / Airmen Billets / Snco Mess Under Age B/R-I Of Ge (Af) Subroto Park, delhi-Delhi

Military Engineer Services has published Tender For Periodical Services To Smq Md Accommodation / Airmen Billets / Snco Mess Under Age B/R-I Of Ge (Af) Subroto Park. Submission Date for this Tender is 23-08-2023. Rough Finishing Tools Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38897448
Corrigendum : Tender For Periodical Services To Smq Md Accommodation / Airmen Billets / Snco Mess Under Age B/R-I Of Ge (Af) Subroto Park
Open Tender
Indian
Delhi
Delhi
23-08-2023

Tender Details

Periodical Services To Smq Md Accommodation / Airmen Billets / Snco Mess Under Age B / R-I Of Ge ( Af ) Subroto Park. 1 Taking Down Cement Plaster Etc On Brick Wall Or Stone Walls Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc And Disposed Off Unserviceable Materials To Out Side Of Mod Land Complete All As Specified And As Directed. 2 M&L 12 Mm Thick Cement Mortar 1:6, On Unven Surface Ofbrick Work Or Concrete Surfaces On Wallsurface Even And Smooth Without Using Any Extra Cement 3 M&L For Rendering 10Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces Incement Mortar ( 1:3 ) As In Ceiling, Complete All As Specified And As Directed 4 M&L 15 Mm Thick Cement Mortar 1:4 On Other Than Fair Faces Of Brick Work Or Concrete Surfaces On Wallsurface Even And Smooth Without Using Any Extra Cement 5 M & L Preparation Of Newly Plastered Or Unplastered Surface And Applying Two Coats Of Distemper Oil Emulsion On Walls Complete All As Specified. 6 M & Lpreparation Of Newly Plastered Surface And Applying Three Coats Of White Wash On Ceilings. 7 M&L For Preparing New Surfaces ( Plastered Or Unplastered ) Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Alkali Resistant Primer On Surfaces Of Walls Complete All As Specified And As Directed By The Engineer-In-Charge. 8 M&L For Preparation Of Old Decorated Surfaces Of Walls Including Washing, Rubbing Down And Stopping Of Distempered And Painted Surfaces And Applying One Coat Of Oil Bound Distemper ( White / Tinted ) On Walls Complete All As Specified And As Directed By The Engineer-In-Charge. 9 M&L For Complete Removal Of Existing Treatment Of Old Decorated Surfaces Of Walls By Steel Wire Brushing; Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salts And Trading Oil And Greasy Spots And Washing, Rubbing Down Andstoping Of Existing Surface And Making The Surface Even And Smooth And Apply Two Coats Of Distemper Oil Emulsion On Walls Complete All As Specified. 10 M&L For Preparation Of Old Decorative Surfaces Including Scraping Down Smoke Dust Mould, Mean Cut Salt And Trading Oils And Greasy Spot Etc. On Ceiling Including Cornices, Plasters Etc. ( Plastered Or Unplastered Surfaces ) And Applying One Coat Of White ( Lime ) Wash On Old Washed Surfaces All As Specified Complete. 11 M&L For Preparation Of Old Decorative Surfaces Including Scraping Down Smoke Dust Mould, Mean Cut Salt And Trading Oils And Greasy Spot Etc. On Wall Including Cornices, Plasters Etc. ( Plastered Or Unplastered Surfaces ) And Applying One Coat Of White ( Lime ) Wash On Old Washed Surfaces All As Specified Complete. 12 M&L For Prepration Ofold Plastered Or Unplastered Surfaces Of Walls And Applying One Coat Of Cement Base Paint , Complete All As Specified And Directed By Engr-In-Charge. 13 M&L For Preparation Of Old Surfaces Of Walls Including Corrices ( Plastered Or Unplastered Surfaces ) By Scraping Down Smoke Soot, Moulds, Moss And Effloresnt Salt And Trading Oil Or Greasy Spots Etc, Including Cornices And Applying One Coats Of Exterior Weather Proof Paint On Old Decorated Any Surfaces Walls / Foot Paths , Etc., All As Specified And As Directed By Engineer-In-Charge. 14 M&L For Complete Removal Of Existing Treatment From External Surfaces Of Walls By Brushes And Washing Down And Stopping Of Surface And Levelling / Edging The Disturbed Portion Plane / Edges Using Necessary Filling Compound Of Putty To Obtain Smooth / Regular / Even Finish Surface With Using Of Sand Paper Etc And Prepare Surface, Applying Two Coats Ofexterior Weather Proof ( Coat ) Paint On Plastered / Concrete Surfaces Of Walls, Paths , Etc., Over A Coat Of Cement Base Paint Primer Complete All As Specified And As Directed By The Engineer-In-Charge. 15 M&L For Preparation Of Old Painted Wooden Surface Of Any Description, Not Otherwise Described Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint. Complete All As Specified And As Directed By The Engineer-In-Charge. 16 M&L For One Coat Of Synthetic Enamel Paint Including Preparation Of Old Decorated Steel Surfaces / Concrete Surfaceof Any Description Over 10 Cm Width Or Girth Not Otherwise Described. 17 Demolition Of Any Type Of Roof Treament ( I.E App Membrance, Brick Tiles, Mud Phuska, Cement Concrete / Lime Concrete Etc ) From Roof Any Thickness Including Leaping Plaster Including Removing The Demolished Material From Roofout Side Defence Land Complete All As Specified And Directed By Engineer-In-Charge. 18 M & L For Cement Concrete 1 : 2 : 4 Type B-0 ( Using 12.5 Mm Graded Stone Aggregate ) Laid As In Paddingover Roof Slabs With Wpc As Per Manufacturer Instruction For Providing Proper Slope Including Finishing Surface By Using Extra Cemnt Even And Fair All As Specified. 19 M&L For Three Layer Prefabricated Atactic Polypropylene Polymer ( App ) Modified 3 Mm Thick Membrane ( Weight Not Less 3 Kg / Sqm ) Reinforced With 160 Gms Polester Non-Woven Fabric With Scratched Tool Before Finishing Roof Surface. When The Concrete Surface Is Still Green, The Roof Surface Shall Be Throughly Wire Brushed Washed Dried Up And Cleaned Of All Foreign Matter And Dust Prior To The Application Of Primer On The Dried Surface One Coat Of Approved Bituminous Primer, Having Density In The Range Of 0.87 To 0.89 / Kg At 25 Dgree And Viscositing Of 70 To 160 Cps Manufactured By The Same Manufacturer @ 0.40 Litres / Sqm Shall Be Applied. App Membrane Shall Be Laid On Primed Surfacetourch Application Mehtod After Allowing 24 Hours Of Primer To Dry. Laying Of App Membrane Shall Be Commneced At The Lowest Level And Worked Upto The Crest. App Membrane Will Normally Be Laid In Length At Right Angle To The Direction Of Slope. The Overlaps Shall Be Of Minimum 100 Mm On Longitudinal Direction And 150Mm On The Transverse Direction. All Overlaps Shall Be Bonded With Bitumen Primer And Levelled By The Heating The Overlaps With Brutane Tourch. This Treatment Shall Be Done By Theapproved Authorised Applicator. Guarantee Of Treatment Shall Be For 10 Years. Thereafter App Membrane Shall Be Painting With Two Coat Of Water Proofing Paint With Aluminium Finish. ( Ii ) Independent Testing Of Membrane For The Approval Technical Parameters Specified Hereinafter Shall Be Carried Out The Approved Laboratories Like National Test House Any Other Govt Approved Laboratory Having Facilities For The Testing Of Membrane. 20 Supply Only Liquid Water Proofing Compound Complete All As Specified And As Directed By Engineer-In-Charge. 21 Disconnecting Existing Tanks Exc 250 And N.Exc 500 Ltrs And Above, Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position. ( Cleaning Repairing, Etc. Measured Separately 22 Dismantling Existing Tanks Capacity Exc. 250 Ltr But N.Exc 500 Ltr, And Removing. 23 S&F Tripple Layer Rotational Moulded Vertical Water Storage Tanks With Closed Tops ( Cylinderical ) Fixhoisted And In Position 500 Ltr Capacity Incl Disconnecting And Refixing The Existing Gi Fitting And Pipe Complete 24 S&F Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed Suitable For Iron Pipe 20Mm Bore Having Weight Not Less Than 210 Gms Complete All As Specified And Directed By Engineer-In-Charge. 25 S&F In Repairs Hdpe Pvc Lid ( Cover ) For 500 / 1000 Litres Capacitypvc Tank Complete All As Specified And Directed By Engineer-In-Charge. 26 M&L For Removing Plants / Sherbs Grown On Wall / Junctions With Roots Duly Rendering Berbicide Chemical And Making Good Of The Existing Brick / Concrete Surfaces Of Area N.Exc 0.50 Sqm Complete All As Specified And As Directed By The Engineer-In-Charge. 27 Demolition Of Cement Concrete ( Un Reinforced ) Paving N. Exc. 15 Cm Thickness ( Below Or Above Ground Floor ) . 28 M&L For Pcc ( 1:5:10 ) Type E-2 Using 40 Mm Graded Brick Aggregate As In Sunken Portioncomplete All As Specified And As Directed 29 M & L For Cleaning The Sunken Floor Surfaces By Wire Brushes, Brooming, Removing Dust By Dismantling Of Floor, Lime Terracing And Applying Following :- ( A ) 10 Mm Thickscreed Bedin Cement Mortar 1:3 Complete Mixed With Water Proofing Compoundas Per Manufacturers Instructions Complete All As Specified And Directed. ( B ) Bitumen Primer Confirming To Is-3384-1965 @ 0.50 Kg Per Sqm. ( C ) Applying A Tack Coat Of Hot Blown Bitumen 85 / 25 @ 1.2 Kg / Sqm Confirming To Is - 702-1998 For Water Proofing Membrane. ( D ) Applying Of Polymeric Water Proofing Membrane Weight Not Less Than 3 Kg / Sqm Over Entire Are With Overlaps And Sealed All As Specified Directed. ( E ) Again Applying A Tack Coat Of Hot Blown Bitumen 85 / 25 @ 1.2 Kg / Sqm Over Water Proofing Membrane. ( E ) Dusting Dry Sand @ 0.75 Kg Per Sqm Over Water Proofing Membrane. 30 S&F In Repair 32Mm Diagalvanised Iron Spoutlightgradeforsunken Portion Completeallspecified And As Directed. 31 Supply And Fixing In Repair Windows / Ventilators Fabricated From 0.60Mm Thick Rollformed Section Made Of Galvanisedsteel Powder Coated ( Base Steel As Per Is-513D Quality ) Galvanised As Per Is-277 With Zinc Of 120Gm / Sqm .Windows / Ventilators Having Frame Suitable For Dual Shutter I.E. Inner And Outer Shutter With Grill, Glazed And Wire Mess Shutter And All Fitting, Fixtures Accessories Incl6mmx12mm Flat Ironwith 10Mm Square Bar M.S. Grills Complete As Specified And Shown In Drawing No Ceaf / Std-191 / 2014, Sheet 1 / 2 & 2 / 2 Dated 11.12.14 ( 4000 Series ) . 32 S & F In Repair Aluminium Door Single Leaf With Anodized Aluminium Frame Of Section 62.5 X 37 X 2.5 Mm Thick, Shutter With Bottom & Middle Rail Of Section 112.50 X 37 X 2.5 Mm Thick And Styles & Top Rail Of Section 83 X 37 X 2.5 Mm Thick With Centrally Locking Arrangement With Lock Make Of ‘Godrej’ Or ‘Link’ 7 Lever And Self Closing Device With Rebate Includingjointingcleats, Fixing Of Builders Hardware Fittings, Necessary Numbers Of Floor Spring And Glazing With 5.5 Mm Thick Ordinary Plain Glass Includingnecessary Fittings, Fixtures & Aluminium Snap Beads Including Taking Down Any Type Of Door Complete All As Specified And Directed. 33 S & F Aluminum Window With Aluminum Anodized Frame Of Aluminum Section 62.5 X 37 X 2.5 Mm Thick With Shutters Having Styles & Rails Of Aluminum Section 44.45 X 44.45 X 2.5 Mm Thick Including Jointing Cleats, Glazing Clips, Rubber Packing, Aluminum Snap Beading, Screws Anodized Aluminum Fittings Such As Hinges, Tower Bolts, Handles Etc Including 5.5 Mm Thick Ordinary Plain Glass Complete. Including Providing And Fixing Aluminum Chequered Grill Of Anodized Section Of Mesh 100X100mm Of 08 Mm Dia Of Bar Fixed To Frame With 20X20 Mm Aluminum Flat With Stainless Steel Wire Mesh Fixed With Screw Including Taking Down Old One Complete All As Specified And As Directed. 34 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specifiedand Directed 35 M&L Non Skid Ceramic Coloured Printed Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tiles Exc 0.11 Sqm But N. Exc 0.18 Sqm, In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over 15 Mm Thick Screed Bed Or Bedding Layer In Cm ( 1:4 ) .Complete All As Specified And As Directed By The Engineer-In-Charge. 36 M&L Non Skid Ceramic Coloured Printed Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tiles Exc 0.11 Sqm But N. Exc 0.18 Sqm, In Floors Or Dado Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over 15 Mm Thick Screed Bed Or Bedding Layer In Cm ( 1:4 ) Complete All As Specified And Directed. 37 M&L Forvitrified Tiles 10Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.38 Sqm, In Floorsetc, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Etc Over 15 Mm Th Screed In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 38 M&L Glazedcoloured Ceramic Tiles In Vertical Surface450 X 300X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specifiedand Directed. 39 Taking Down Or Up Steel Water Tubing And Connections Of 15 Mm Bore Removing The Debris Including Mortar Out Side Defence Land Complete All As Specified And Directed By Engineer-In-Charge. 40 All As Per Above Item No 39 But 20 Mm Bore. 41 S & F Steel Water Tubing, Galvanised, Medium Grade, Isi Marked With All Fittings Andfixed On Walls And Ceilingsor Laid In Floors Bore Of Pipe 15 Mm Complete All As Specified And Directed By Engineer-In-Charge. 42 All As Per Item No 41 Above But 20 Mm Bore. 43 Dismantling Of Stone Slabs Laid, Bedded And Pointed In Any Mortar Complete All As Specified And Directed 44 M&L Machine Cut Kota Stone Slab 18 To 20 Mm Thick Laid Over And Inluding 15 Mm Thick Screedbed In Cm 1:6 Laid And Jointed With Grey Cement Slurry Including Cutting And Pre Polished Mirror Polishing All As Specified And Directed By Engr-In-Charge. 45 All As Per Item No44 Above But In Skirting Over 10Mm Thick Rendering In Cement Mortar 1:4 Pre Polished Complete. 46 M&L For 75Mm Thick Cement Concrete 1:4:8 Type D2 ( Using 40 Mm Graded Stone Aggregate ) As In Sub Base For Floors Finishes All As Specified. 47 S&F Precast Machine Pressed Pcc Interlocking Paver Block Of 60 Mm Thickness, M-35 Grade Of Any Shape And Size Confirming To Is -15658-2006 With Grey Cement And Pigment As Approved Complete All As Specified And Directed. 48 M&L Forsand Filling Under Floors Or In Foundations Including Watering And Consolidation In Layers Not Exc 25Cm Thickness All As Specified And Directed. 49 M&L For Coloured Chequered Cement Concrete Tiles 25Cm X25cm Or 30Cmx30cmx22 / 25 Mm Thick, Set, Jointed & Pointed In Neat Cement Slurry Over 20 Mm Screed Bed In Cm ( 1:6 ) , Demoilition Of Pcc And Removing Of Debris Away From Mod Land, Complete All As Specified And As Directed By The Engineer-In-Charge 50 S&F In Reapir Vitreous China Squatting Pan “Orrisa” Pattern Of Size 580Mmx440mm “White” With Integral Foot Rest ( Excluding Flushing Cistern And Flush Pipe ) Incl Provision Of Cement Concrete Bedding, Ci ‘P’ Trap 100Mm Dia Connection To Trap And Flushing Pipe, Anti-Syphonage Complete All As Specified And Directed By Engineer-In-Charge. 51 S&F In Repairs Vitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) Excluding Flushing Cistern And Flush Pipe And Including P Or S Trap And Seat Cover Complete All As Specified And As Directed By Engineer-In-Charge. 52 S&F10 Litre Pvc Valve Less Symphonic Action Type Low Levelflushing Cistern With Inlet Ball Valve Float And Handle Incl Cibracketand 32Mm Bore Pvc Flush Pipe And Connection To Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 53 S&Fplastic Water Closet Seat Cover White Closed Pattern With Flat Bottom And Cover Incl Mild Steel Chromium Plated Hinging Device Complete All As Specified And As Directed By Engineer-In-Charge. 54 S&F In Repair Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed Suitable For Iron Pipe 20Mm Bore Having Weight Not Less Than 210 Gms Complete All As Specified And Directed By Engineer-In-Charge. 55 S& Finrepair110 Mmborepvc ( Swr ) Pipesinglesocketedinany Lengthwithrubber Ringjoints, Laidintrenchesorinfloorsetcincludingremovingfromsite Completeallasspecifiedanddirectedbyengr - In- Charge. 56 S&F In Repair Pvc ( Swr ) Bends Any Radius For 110 Mm Bore Pvc Pipe With Cement Joints Complete All As Specified And As Directed. 57 S&F Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal ( Supplied And Fixed Bore Of Pipe In 110Mm ) 58 S& Finrepair75 Mmborepvc ( Swr ) Pipesinglesocketedinany Lengthwithrubber Ringjoints, Laidintrenchesorinfloorsetcincludingremovingfromsite Completeallasspecifiedanddirectedbyengr - In- Charge. 59 S&F In Repair Pvc ( Swr ) Bends Any Radius For 75 Mm Bore Pvc Pipe With Cement Joints Complete All As Specified And As Directed. 60 M & L Cleaning And Removing All Scales And Dirt, Etc, From Water Tanks And From Mouths Of Circulating Pipes, Etc ( Capacity Of Tank Exc 250 Ltrs & N Exc 500 Ltrs ) And Writing Date Of Cleaning On Water Tank. 61 S&F In Repair Curtain Rods With Mild Steel Conduit Pipe 20 Mm Bore Pvc Coated Of 1 Mm Thick Including Temples, Brackets Etc Complete All As Specified And Directed By Engineer-In-Charge 62 S&F In Repair Bib Taps Long Body, Cast Copper Alloy, Fancy Type With Crutch Or Butterfly Handles, Chromium Plated, Screwed Down To Iron Pipes Or For Brass Ferrule Of 15 Mm Borecomplete All As Specified And Directed By Engineer-In-Charge. 63 S & Fin Repair Ptmtlong Body Bib Tap 15Mm Dia Pipe With Crutch Or Butter Fly Handle Screwed Down, Screwed For Iron Pipe And Fixed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-08-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail