}

Tender For The Rate Contract And Supply Of Medical Equipment To Chhattisgarh Medical Services Corporation Limited, Raipur-Chhattisgarh

Government Departments has published Tender For The Rate Contract And Supply Of Medical Equipment To Chhattisgarh Medical Services Corporation Limited. Submission Date for this Tender is 11-08-2023. Medical Equipment Tenders in Raipur Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

38883919
Tender For The Rate Contract And Supply Of Medical Equipment To Chhattisgarh Medical Services Corporation Limited
Open Tender
Indian
Chhattisgarh
Raipur
11-08-2023

Tender Details

Tender For The Rate Contract And Supply Of Medical Equipment To Chhattisgarh Medical Services Corporation Limited 1 EQP0147 Dental X-Ray 2972 2 EQP0156 Electrophoresis Machine 55375 3 EQP0174 Nebulizer (baby) 1000 1. Dental X-Ray (EQP0147) 1. Generator High Frequency DC 2. Tube kV 50 to 70 kV (DC) Selectable 3. Tube mA 4-8mA Max 4. Exposure Time 0.01s to 3.2s settable 5. Focal Spot 0.4mm IEC 6. Duty Cycle 1:30 Auto Control 7. Leakage Radiation <10mR/hr(<0.1mGy/hr) 8. Source to Skin Distance 200mm Minimum 9. Line Voltage 190V-240V (Inbuilt Regulation) 10. Line Current 3A 11. X-ray Field 60mm at 200mm 12. Total Filtration 2mm Al eq 13. X-ray Controls Wired hand held + IR Remote 14. Control Panel Graphical Display with keypad with Anatomical Presets Mounting Options Wall Mounted Scissor Arm[Max reach 1650mm + Extension] 2. Electrophoresis Machine (EQP0156) Tank Specification  Should have the capacity to hold at least 3x10 cm size cellulose acetate paper  Should have the electrode assembly, tank, lid with power cables and mini cell buffer dam.  Length: 15 cm, Width: 10 cm, Height: 6cm Height of buffer dam 4 cm and width of buffer dam 7 cm Power pack specification  Should have output range of 10-300 B and 4-400mA. Fully adjustable  Should have poer of approx 75 W fully adjustable.  Should have at least 2 pairs of output jacks  Operational voltage should be 220 ± 20 V  The power supply should be capable to operate minimum two electrophoresis units  Type of output-constant voltage and constant current. 3. Nebulizer (Electric) (EQP0174) NAME Name Nebulizing systems GENERAL 1. USE 1.1 Clinical purpose designed to generate aerosolized medication/fluids (finely dispersed airborne droplets in a liquid phase) intended to be inhaled by a patient witha respiratory disorder. 1.2 Used by clinical department/ward All TECHNICAL 2. TECHNICAL CHARACTERISTICS 2.1 Technical characteristics (specific to this type of device) Medicine cup capacity of minimum 5ml. 2.2 Settings Manual 2.3 Users interface Manual 2.4 Software and/or standard of communication (where everrequired) NA 3. PHYSICAL CHARACTERISTICS 3.1 Dimensions (metric) Should be compact 3.2 Weight (lbs, kg) <2kg. 3.3 Configuration 3.4 Noise (in dBA), heat dissipation <60dBA 3.5 Mobility, portability Yes 4. ENERGY SOURCE (electricity, UPS, solar, gas, water, CO2 ) 4.1 Power Requirements 220 V AC + 10%, 50Hz power supply; 5A plug; 4.2 Battery operated NA 4.3 Tolerance (to variations, shutdowns) ± 10% of input AC 4.4 Protection Electrical protection by resettable overcurrent breakers or replaceable fuses,fitted in both live and neutral lines 4.5 Power consumption Should be compatible with other life saving equipments running parallel 4.6 Other energy supplies NA Done by : (name/institution) HCT/NHSRC NAME name Nebulizing systems GENERAL 1. USE 1.1 Clinical purpose designed to generate aerosolized medication/fluids (finely dispersed airborne droplets 1.2 Used by clinical department/ward All TECHNICAL 2. TECHNICAL CHARACTERISTICS 2.1 Technical characteristics (specific to this type of device) Medicine cup capacity of minimum 5ml. 2.2 Settings Manual 2.3 Users interface Manual 2.4 Software and/or standard of communication (where everrequired) NA 3. PHYSICAL CHARACTERISTICS 3.1 Dimensions (metric) Should be compact 3.2 Weight (lbs, kg) <2kg. 3.3 Configuration 3.4 Noise (in dBA), heat dissipation <60dBA 3.5 Mobility, portability Yes 4. ENERGY SOURCE (electricity, UPS, solar, gas, water, CO2 ) 4.1 Power Requirements 220 V AC + 10%, 50Hz power supply; 5A plug; 4.2 Battery operated NA 4.3 Tolerance (to variations, shutdowns) ± 10% of input AC 4.4 Protection Electrical protection by resettable overcurrent breakers or replaceable fuses,fitted in both live and neutral lines 4.5 Power consumption Should be compatible with other life saving equipments running parallel 4.6 Other energy supplies NA 5. ACCESSORIES, SPARE PARTS, CONSUMABLES 5.1Accessories & Spares With necessary accessories- nebulization mask(both adult and pediatric size), PVC tubing for nebulizer (two pair extra); cable cord 5.2Consumables/reagents (open,closed system) aerosol/medicinal solutions 6. ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATONS 6.1Atmosphere/Ambiance (air conditioning, humidity, dust ...) Capable of being stored continuously in ambient temperature of 0 to 50 degC and relative humidity of 15 to 90%. Capable of operating continuously in ambient temperature of 10 to 40 deg C and relative humidity of 15 to 90%. 6.2Users care, Cleaning, Disinfection & Sterility issues The unit should be cleanable with alcohol and/or other chemical agents. 7. STANDARDS AND SAFETY 7.1Certificates (pre-market, sanitary, ..) FDA (US)/CE (EU) and BIS/ISO 13485:2003; ISO 27427-2013; IEC-60601-1. 8. TRAINING AND INSTALLATION 8.1 Pre-installation requirements:nature, values, quality, tolerance Supplier to perform installation, safety and operation checks beforehandover. 8.2 Requirements for sign-off Certificate of calibration and inspection from the factory. 8.3 Training of staff (medical,paramedical, technicians) Training of users in operation and basic maintenance shall be provided. 9. WARRANTY AND MAINTENANCE 9.1 Warranty 3 Years 9.2 Maintenance tasks Maintainance manual detailing complete maintaining schedule 9.3 Service contract clauses,including prices Local clinical staff to affirm completion of installation 10. DOCUMENTATION 10.1 Operating manuals, servicemanuals, other manuals Advanced maintenance tasks required shall be documented User, technical and maintenance manuals to be supplied in englishlanguage. List to be provided of equipment and procedures required for localcalibration and routine maintenance 10.2 Other accompanying documents List to be provided of important spares and accessories, with their part numbers and cost. Certificate of calibration and inspection to be provided. 11. NOTES 11.1 Service Support Contact details (Hierchy Wise; including a toll free/landlinenumber) Contact details of manufacturer, supplier and local service agent to beprovided 11.2 Recommendations orwarnings List to be provided of important spares and accessories, with their part numbers and cost. Certificate of calibration and inspection to be provided.

Key Value

Document Fees
INR 5000 /-
EMD
INR 55375.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail