| 1 | Providing and fitting , fixing 3 pole power contractor Type 415, 50 HZ ( L & T make) as per direction of the Engineer-in-Charge |
| 2 | ML 1.5 |
| 3 | ML2 |
| 4 | Providing and fitting , fixing Bimetal overload relay Type ML series L & T make as per direction of the Engineer-in-Charge.(i)15-21 Amp |
| 5 | ii).20-32 Amp |
| 6 | Providing and fitting , fixing Std. operating coil for 415 V , 50 HZ, L & T make as per direction of the Engineer-in-Charge.(i) ML 1.5 |
| 7 | (ii) ML2 |
| 8 | Providing and fitting, fixing combination coil ML2 with Timer L & T make as per direction of the Engineer-in-Charge. |
| 9 | Providing & fitting, fixing Thermal Timer Type GT 200 , 415V , 50 HZ for 5-18 Sec, L & Tmake as per direction of the Engineer-in-Charge. |
| 10 | Providing and fitting, fixing Electronic Timer Type ET100, 415V, 50Hz, for 9-30 Sec, L & T make as per direction of the Engineer-in-Charge. |
| 11 | Providing and fitting , fixing spare kit withoutcoil ( L & T) make as per direction of the Engineer-in-Charge.(i).ML1.5 |
| 12 | ii).ML2 |
| 13 | Supplying and fitting, fixing of 3.5 mm thick rubberinsertion for different dia. |
| 14 | Providing & fitting , fixing of fully Automatic star Delta Motor Starter sheet enclosure for submersible motor output at 415 volt , 3 ph, 50 HZ relay range 20-32A ( ML2 , FASD cat No.SS90705) ( L & T make). |
| 15 | Providing & fitting fixing of fully automatic star Delta Motor starter in sheet enclosure for submersible motor output at 415 V , 3Ph , 50 HZ relay range 13-21A ( ML 1.5 FASD Cat No. SS90705 L & T make). |
| 16 | Providing and fitting fixing Single phasing preventor selectable over voltage on delay 5 sec & off delay 15 sec phase asymmetry 10% L & T/BCH/HAVELS/Siemens etc. make complete as per specification and direction of the Engineer-in-charge. |
| 17 | Supplying & fitting , fixing of 2/3HP submersible panel starter, relay range(17.40-24.00 Amps of BCH make. |
| 18 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), current range415/500 Volt, L & T / Havell\"s/BCH make etc. complete as per specification and direction of the Engineer-in-charge. |
| 19 | i).32Amps |
| 20 | ii).63 Amps |
| 21 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge.(i).10sqmm |
| 22 | ii).16sqmm |
| 23 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 24 | Providing and fitting fixing of moving iron type, Range 0-100/0- 200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 25 | Providing & fitting, fixing of Volt-Ammeter 500V, 60A,Cat No.CS94817EOTO (L&T make) as per specification and direction of the Engineer-in-charge. |
| 26 | Providing & fitting ,fixing of 40A, double pole Isolator, Cat No.BE204000 (L&T make) as per specification and direction of the Engineer-in-charge. |
| 27 | Providing & fitting of 6A, 2 pin plug top, Cat No.OP02W06(L&T make) as per specification and direction of the Engineer-in-charge. |
| 28 | Providing & fitting, fixing of 6A, 3 pin plug top, Cat No.OP01W06(L&T make) as per specification and direction of the Engineer-in-charge. |
| 29 | Providing & fitting fixingof 16 Module grid frame+ cover, Cat No.OF16WOO (L&T make) as per specification and direction of the Engineer-in-charge. |
| 30 | Providing & fitting fixingof 16 Module surface box Cat No.OW16WOO (L&T make) as per specification and direction of the Engineer-in-charge. |
| 31 | Providing & fitting, fixing of 6A, 2 pin euro socket, Cat No.OC11W06(L&T make) as per specification and direction of the Engineer-in-charge. |
| 32 | Providing & fitting, fixing of 6A, 1-way switch with LED, Cat No.OS13W06(L&T make) as per specification and direction of the Engineer-in-charge |
| 33 | Providing & fitting, fixing of63 Amps 415 V kit kat rewireable fuseCat No. IHKKRN4032(L&T make) as per specification and direction of the Engineer-in-charge. |
| 34 | Providing & fitting, fixing of100 Amps 415 V kitkat rewireable fuseCat No. IHKKRN4100(L&T make) as per specification and direction of the Engineer-in-charge. |
| 35 | Providing & fitting, fixing of MK1 starter contactor 220VCat No. SS95200K000L&T makeas per specification and direction of the Engineer-in-charge. |
| 36 | Providing & fitting, fixing of MK1 starter relay,9-14ACat No. SS9003500AOL&T makeas per specification and direction of the Engineer-in-charge. |
| 37 | Providing & fitting, fixing of MK1 starter standard operating coil220VCat No. SS90044000L&T makeas per specification and direction of the Engineer-in-charge |
| 38 | Providing & fitting, fixing of MK1 starter thermal timer without combination coil Cat No. SS90224000L&T makeas per specification and direction of the Engineer-in-charge. |
| 39 | Providing & fitting, fixing of MK1 starter Aux. contact block :1 NO+1NCCat No. SS90120000L&T makeas per specification and direction of the Engineer-in-charge. |
| 40 | Providing & fitting, fixing of MK1 starter push bottom unit Cat No. SS90004000L&T makeas per specification and direction of the Engineer-in-charge |
| 41 | Providing & fitting, fixing of MK1 starter Arc shieldCat No. SS50004000L&T makeas per specification and direction of the Engineer-in-charge |
| 42 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to IScode for submersible motor withall necessary equipments & fitting s as requiredas per specification and direction of the Engineer-in-charge.i.4.0 sqmm |
| 43 | ii.10.0 sqmm |