}

Tender For Provision Of Tech Accommodation For Dental Unit At Yol, Kangra-Himachal Pradesh

Military Engineer Services has published Tender For Provision Of Tech Accommodation For Dental Unit At Yol. Submission Date for this Tender is 23-10-2023. Vehicle Hiring Service Tenders in Kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38852844
Corrigendum : Tender For Provision Of Tech Accommodation For Dental Unit At Yol
Open Tender
Indian
Himachal Pradesh
Kangra
23-10-2023

Tender Details

Tender For Provision Of Tech Accommodation For Dental Unit At Yol ; 1 Lumpsum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I. 2 Lumpsum Price Worked Out By The Contractor For Internal Watersupply Works As Listed In Schedule A Part-Ii. 3 Lumpsum Price Worked Out By The Contractor For Plumbing Works As Listed In Schedule A Part-Iii. 4 Lumpsum Price Worked Out By The Contractor For Internalelectrification Works As Listed In Schedule A Part-Iv. 5 Lumpsum Price Worked Out By The Contractor For Rain Water Harvesting Works As Listed In Schedule A Part-V. 6 Lumpsum Price Worked Out By The Contractor For Site Clerance And Development Works As Listed In Schedule A Part-Vi. 7 Lumpsum Price Worked Out By The Contractor For Road Path And Culvert Works As Listed In Schedule APart-Vii. 8 Lumpsum Price Worked Out By The Contractor For Protective Works As Listed In Schedule A Part-Viii. 9 Lumpsum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule A Part-Ix. 10 Lumpsum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-X. 11 Lumpsum Price Worked Out By The Contractor For Security Fencing And Compound Wall Works As Listed In Schedule A Part-Xi. 12 Lumpsum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Xii. 13 Lumpsum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-Xiii. 14 Lumpsum Price Worked Out By The Contractor For Hot Water Supply As Listed In Schedule A Part-Xiv. 15 Lumpsum Price Worked Out By The Contractor For Demolition And Dismantling Work As Listed In Schedule A Part-Xv. 16 Internal Electrification Supply And Fixing Of Dboxx Mcb Protected Socket With Sheet Steel Enclosure Single Pole 25 Amp With 3 Pin Plug Topfor Ac Connection From Socket Point To Stabilizer Complete All As Specified And As Directed. 17 Supply And Fixing For Led Lamp 10 Watt B-22 Holder Base With Polycarbonate Body And Aluminium Heat Sink Warm White Complete All As Specified And Directed By Engineer - In - Charge. 18 S & F High Performance Ip66 Led Street Light 20 Watt, Housing Madeof Die-Cast Aluminium, With Street Optic Lens, With All Accessories And Connecting Up With And Including Provision Of 3 Core Flexible Copper Wire Of Size 1.5Sqmm From Ceiling Rose, And 20W Led Light Etc. Drawn Through And Including 32Mm Bore Gi Light Grade Protecion Pipe Upto 1.0M Length With Suitable Fixing Accessories On Walls, Complete All As Specified And As Directedcomplete All As Specified And As Directed. 19 S&F Supply And Fixing Mccb 160 Amp 415V 25Ka Fixed Thermal And Magnatic 3 Pole In The Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed. 20 S & F Vtpn Dbs Double Door4 Way Suitable For G Frame Mccb Incomer, Ip 43 Protection 415 V Ac, 50 Hz Ac Loadline Dbs Are Fitted With Bus Bars, Neutral Links, Blanking Plates Complete All As Specified And Directed 21 External Electrification Supply, Installation, Testing And Commissioning Of Lt Panel Of Suitable Size For 415 Volts, 50 Hz, ( 3 Phase, 4 Wire Supply ) Floor Mounted, Factory Assembled, Outdoor Type Weather And Vermin Proof ( Protection Class Ip-54 ) Made Out And 3.15Mm Thick Ms Sheet Crca Sheet Aluminiumbus Bar Of Suitable Size ( Current Carrying Capacity Upto 500 Amp ) With Hingedopening, Rubber Lining , Lockingarrangement, Painted Externally And Internally With Two Coats Of Synthetic Enemel Paint. Lt Panel Compromising Of Following : ( A ) Mccb4 Pole , 400 Amps, Rupturing Capacity 35 Ka, 440 Volts, Adjustable Type - 01 Nos As Incoming ( B ) Mccb4 Pole , 200 Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type 01 No As Outgoing ( C ) Mccb4 Pole , 100 Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type - 02 Nos As Outgoing ( D ) Mccb4 Pole , 63 Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type - 03 Nos As Outgoing ( E ) Mcb Spn 32 Amp , Rupturing Capacity 10 Ka, 230 Volts - 02 Nos ( F ) Timer Switch 415A Three Phase Of 20A Rating With Contactor Fitted Inside Steel Enclouser-01 No ( G ) Indicator Led Phase Lamps 03 Nos ( R, Y, B ) - 01 Set ( H ) Volt Meter 0-500 Volts With Pts And Selector Switch - 01 No ( J ) Ammeter With Selector Switch With Cts - 01 No ( K ) Platform Of Suitable Size For The Feeder Pillar Board With Pcc 1:3:6, Type C-2, 300Mm Thick In Foundation , Using 20Mm Graded Stone Aggregate And Grouting Legs Of Panel All As Specified & As Directedby Engineer-In-Harge. 22 Supply, Installation, Testing And Commissioning Of Lt Panel Of Suitable Size For 415 Volts, 50 Hz, ( 3 Phase, 4 Wire Supply ) Floor Mounted, Factory Assembled, Outdoor Type Weather And Vermin Proof ( Protection Class Ip-54 ) Made Out And 3.15Mm Thick Ms Sheet Crca Sheet Aluminiumbus Bar Ofsuitable Size ( Current Carrying Capacity Upto 200 Amp ) With Hingedopening, Rubber Lining , Lockingarrangement, Painted Externally And Internally With Two Coats Of Synthetic Enemel Paint. Lt Panel Compromising Of Following : ( A ) Mccb4 Pole , 100 Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type - 01 Nos As Incoming ( B ) Mccb4 Pole , 63Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type - 01 Nos As Outgoing ( C ) Mccb4 Pole , 32Amps, Rupturing Capacity 25 Ka, 440 Volts, Adjustable Type - 01 Nos As Outgoing ( D ) Indicator Led Phase Lamps 03 Nos ( R, Y, B ) - 01 Set ( E ) Volt Meter 0-500 Volts With Pts And Selector Switch - 01 No ( F ) Timer Switch 415A Three Phase Of 20A Rating With Contactor Fitted Inside Steel Enclouser-01 No ( G ) Indicator Led Phase Lamps 03 Nos ( R, Y, B ) - 01 Set 23 S&F Ms Junction Box Out Door Tye Of Size 300 Mm X 200 Mm X 150 Mm Made From 16 Gauge Ms Sheet With Front Openable Hinged Cover Complete With Two Number Aluminium Bus Bars Mounted On Porcelain Insulator Including Clamps Of Ms Flat Iron 25 X 3 Mm With Bolts And Nuts And One Mcb Spnof 10A, 10 Ka For On / Off Street Light To Fixed On Pole All As Specified And Directed. ( Note:- Box To Be Painted Inside And Outside With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer ) . 24 M&L For Street Light Braket 1.20 M Long Made Of Gi Pipe 40Mm ( Medium Grade ) Bend To 120 With Attached Suitable Size Of Ms Clamp For Fixing Of Street Light Complete All As Spd And Directed. 25 Supply And Fix Hand Dryer High Speed Flow Sensor Operated Wall Mounted Made Of Stainless Steel Body Complete All As Specified And Directed By Engr - In - Charge. 26 Supply And Fix Soap Dispenser Automatic Type 800 Ml Cap Abs Body Wall Mounted Complete All As Specified And Directed By Engr - In - Charge. 27 Material And Labour Platform Brick Masonry With Surface Finishing Using Extra Cement For The Installation Of Transformer Of Size 3000X2500x1200 Mm Complete With Chain Link Fencing And Gate All As Shown In Drg No. Cepz / Td / 350 / 08 Sheet 1 / 2 And As Specified And Directed By Engr-In-Charge. 28 Cutting Of Roads For Laying Of Pipe Of Any Size And Type, Complete All As Specified And Directed.Repair To Road Cutting By Providing Soling With Broken Boulders Or Quarried Stone And Applying Cold Emulsion Mixed With Aggregate As Per Existing Specifications Including Necessary Compaction By Rolling Etc. Match Complete All As Specified And Directed. 29 Supply, Install, Testing And Commissioning Of 11Kv / 0.433K V, 3 Phase, 50Hz, Dyn-11 Vector Group, Step Down, Outdoor Type, Copper Wound, Onan Type Transformers Of Capacity 250Kva With On Load Tap Changer With Rtcc ( Olg Make ) Andhigh Voltage Windings For Varying Low Or High Voltage In The Range Of +5% To -15%In 17 Steps. Class A Of Thermal Insulation Suitable For Ambient Temperature 45º C. Maximum Winding Temprature 105º C The Following Fittings Shall Be Provided With All Required Accessories:- Rating & Terminal Marking Plate, Earthing Terminals, Lifting Lugs For Main Tank & Top Cover, Filter Valve , Drain Cum Sampling Valve, Thermometer Pocket, Dial Type Oil Temperature Indicator, Air Release Plug, Silica Gel Breather, Oil Conservator, Explosion Vent, Inspection Cover, Arcing Horn, Radiators Mounted On Tank, 4 Nos. Bi-Directional Rollers, First Filling Of Transformer Oil As Per Is:335, Magnetic Oil Level Gauge, Oil Temperature Indicator, Winding Temperature Indicator, Marshalling Box, Epoxy Bushing, Pu Paints, Palm, Lv Bus Bar, Radiator Valves, Cable Box On Lt Side & Cable Box On Ht Side. Transformer Shall Compliance Tois:1180 & Is:2014 All Parts Latest As On Date Whichever Is Higher. Complete With All Accessories The Transformer Shall Be Delivered Along With After Complete Factory Tests And Temprature Rise Test, Operational & Maintenance Manual And Test Certificate Of Unconditional Guaranteed Against Manufacturing Defects For A Period Of 18 Months From The Date Of Supply. Make : Abb / Schneider / Bhel / Siemens Complete All As Specified:- Note : ( I ) The Erection Of Transformer Shal Be Done Under The Supervision Of ManufacturerS Auth Rep & Certificate In This Regard Shall Be Submitted By Contractor Duly Signed By Auth Rep Of Manufacturer & Engineer-In-Charge. 30 ( Ii ) Rtcc And Avr Panel Shall Be Suitable For Automatic Voltage Regulation With Master Follower Scheme With Tap Position Indicator As Per Tap Indication In The Oltc Mechanism.Rtcc Should Also Be Provided With Control Gear In Respect Of Fan On / Off Indication, Auto & Manual Control Switch Ac Supply On And Tap Changer In Progress Indication Lamp, Tap Struck Indication And Alarm. ( Iii ) The Core Shall Be Constructed From High Grade , Non Ageing, Prime Grade Crgo With M4 Grade Or Better, Silicon Steel Laminations And Shall Be Of Bottle Ness Design . The Core Material Shall Be Purchased Directly From Manufacturer ( Posco / Nippon / Novex / Ak Steels ) Or From Their Accredited Marketing Organisation . ( Iv ) Manufacturer Shall Have In House Automated Core Cutting Facility To Ascertain That There Is No Mixing Of Second Grade Core . ( V ) The Core And Core Assembly Should Be Dried Through A High Efficient Vaccum Drying Autoclave For Heating And Drying. ( Vi ) Manufacturer Shall Have In House Nabl Accredited Lab To Ascertain The Authenticity Of Test Results. ( Vii ) Inspection Of Transformer Shall Be Carriedout By The Representative Of Accepting Officer In The Factory Promises Before Despatch. 31 External Water Supplym&L For Brick Masonary Valve Pit Of Size 900Mmx900mmx900mm ( Internal Dimension Of Chamber ) With Earth Work In Any Type Of Soil, Pcc M-10 Type C-2 Using 40Mm Graded Crushed Stone Aggregate As In Foundation, Bricks Work In Cm 1:6, 23 Cm Thick, 15 Mm Thick Plaster In Cement Mortar 1:4 Internally And Externally Flush Pointed In Same Mortar As The Work Proceeds Out Side Of Valve Pit. Flooring Shall Be 40 Mm Thick In Pcc M-15 ( Nominal Mix ) Laid Over 75 Mm Thick Hard Core. Top Cover Shall Be Made Out Of Ms Sheet 3.15Mm Thick Fixed In Angle Iron Frame Made Out Of Angle Iron 40X40x6mm With Two Number Of Hinges On One Side And Locking Arrangement At Other Side With 50 Mm Pad Lock Complete Including Painting With 2 Coat Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Shown On Drawing. 32 M&L For Cutting Of Existing Ms Pipe Two Cut Of Dia 150Mm In Position For Intersection Of Newtee Of Size 150X150x80 Mm Dia For Branch Connection With All Fitting Complete All As Specified And Directed. 33 Rain Water Harvestingm&L For Trial Bore Of 300Mm Dia Upto 200Mtr Depth Below Ground Level In Any Kind Of Soil Strata Including Hard Stone / Boulder Etc Cpmplete All As Specified And As Directed By Engineer-In-Charge. 34 Central Air Compressor Unitsupply, Fixing, Testing And Commissioning Of Centralised Air Compressor Unit Dental Compressor Consists Of 8 Nos Of Cylinder With 90 Ltr Tank For Up To 10 User, Having Operating Voltage 415 Volts , 50 Hz , Pressure Range 5.5 To 7.5 Bar, And Compromisingof Following : ( A ) 2 Aggregate With Membrane Dryser Of 8.5 Hp. ( B ) Composite Pipes Having 32Mm ( Internal Dimension ) And 40Mm ( External Dimension ) = 350 Rm ( C ) Other Accessories:- ( Fitting Of Brass ) Chair Side Gate Valve, Main Line, Equal Elbow , Male Thread Connector, Female Thread Connector, T Connector, Clamps To Hold The Pipeline ( Qty As Required At Site ) ( D ) Air Conditioner For Dental Compressor Room - 01 No ( E ) Fire Fighting For Compressor Room - 01 No ( F ) Clinical Visualization System - 01 Noincluding Cabling For Electrical Connection With Three Phase Supply And Foundation As Recommeded By The Manufacturer Complete All As Spd And Directed By Engr - In - Charge. 35 Hot Water Supply Supply, Installation, Testing And Commissioning Of Solar Water Heating System With Etc Techonology Of Capacity 300 Lpd With Electric Backup As Per Recommendations Of Manufacturer Suitable For Single Phase 220 Volts Ac Supply Complete With Etc Type Collectors , Hot Water Tanks , Tank Stands Etc With The Following Specifications :- ( A ) Collector Etc Type With Nos, Size, Level Of Vaccum Transmittance Of Cover Glass Tubes, Reflectance Of Glass Tubes, Absorbance Of Glass Tubes, Type Of Coating And Reflectance Of Coating As Recommended By Manufacturer Having Wind Resistance Upto 100 Km, With Freezing Resistance Minus 20 Degrees C Heating Up Coefficent 240 Degrees C Having Average Thermal Efficiency 58.76% And Maximum Rise In Temp 53.04 Deg C Without Night Losses Fixed At Angle Of Inclination From Horizontal, As Per Recommendations Of Manufacturer. ( B ) Hot Water Tank : Hot Water Tank Of 300 Itrs Capacity Made Out Of Stainless Steel Sheet Not Less Than 0.5Mm Thick Duly Insulated With Puff Insulation 50Mm Thick Having Density Not Less Than 36 Kgs Having Thermal Conductivity 0.29M / K Duly Covered With Ppgi Cladding Fixed With Temperature Gauge, Inlet And Outlet Valves Of Suitabvle Size Duly Installed On Staging Fabricated Out Of Ms Angle Of Appropriate Size As Recommended By Manufacturer Duly Fixed Properly And Painted With Two Coats Of Anti Corrosive Paint Over A Coat Of Red Oxide Primer. Note:- Pcc / Foundation Work As Recommended By The Manufacturer Shall Be Deemed To Be Included In The Rate Quoted For This Work. 36 Air Conditioning & Refrigerationsupply And Fix Air Cooled Split Unit Air Conditioner Electric Driven, Outdoor And Indoor Unit Single Phase Of Capacity Of 1.5 Tr, Bee 5 Star Rated ( Hot And Cold Type ) With Ms Angle Iron Stand For Fixing With Nut Bolt Of Outdoor Unit, Drain Pipe Upto 5-7 Mtr Suitable For Water Outside Area Of Bldg Complete All As Specified And As Directed By Engr-In-Charge. 37 Supply And Fix Air Cooled Split Unit Air Conditioner Electric Driven, Outdoor And Indoor Unit, Single Phase Of Capacity Of 2.0 Tr, Bee 5 Star Rated ( Hot And Cold Type ) With Ms Angle Iron Stand For Fixing With Nut Bolt Of Outdoor Unit, Drain Pipe Upto 5-7 Mtr Suitable For Water Outside Area Of Bldg Complete All As Specified And Directed By Engr-In-Charge. 38 Supply And Fix Voltage Stablizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stablized At 230 V With Accuracy Of + 2.5% And Capacity 5 Kva Complete All As Specified. 39 Supply And Fix Refrigerator, Electric Driven ( Single Phase ) , Capacity Of 195 Litres, Bee 5 Star Rated Complete All As Specified And As Directed. 40 Supply, Installation, Commissioning Of Water Cooler Fully Stainless Steel Body Electric Driven Single Phase Having Approx Storage And Nominal Cooling Capacity Of 150 Litres Per Hour With Ms Stand For Fixing Complete All As Specified And As Directed. 41 Dg Set Supply, Install, Testing And Commissioning Of Outdoor Type Factory Assembled Diesel Driven Generating Set With Silent ( Acoustic ) Enclosure With Fully Wired Alternator Ac For Ambient Conditionsto Give Output Of 62.5 / 63 Kva ( 50 Kw ) Continuous Rating At Power Factor 0.8, 415 Volts + 2.5% Ac 3 Phase, 4 Wire, 50 Hz + 1 %, 1500 Rpm Directly Coupled With Diesel Engine Water Cooled Mounted On Common Base Frame Placed On & Including Pcc Platform With Floor Mounted Fuel Tank Of Adequate Capacity With Fuel Lines, Anti Vibration Pads, Standard Control & Amf Panels And Other Accessories Etc Complete All As Specified & Directed Consisting Of Following :- ( A ) Prime Mover ( Diesel Engine ) :- Adequate Capacity Diesel Engine Of Standard Design Consist Of Direct Injection Type, Turbo Charged Four Stroke, Liquid Cooled Technology Conforming To Bs 5514 And Is 10000 Suitable For Prime Duty Generating Set 62.5 Kva / 50 Kw Of Suitable Bhp @ 1500 Rpm With Multi Cylinders To Drive Independently Alternator As Per Site Condition After Generating And Reducing Power Consumed By Accessories, Directly Coupled Through Coupling Having Overload Capacity Of 10% For One Hour In Every 12 Hrs Continuous Runningmounted On Base Frame Withfollowing Salient Features And Standard Accessories For Safe Handling & Operation Of Engine As Under:- ( A ) The Gen Set Should Have Capacity To Run Continously In Variable Load Condition For Unlimited Hoursand Should Also Have A 110% Load Capacity Of 01 Hour In Every 12 Hours Of Operation. ( B ) Air System - Inlet & Exhaust Comprising ( I ) Dry-Type Paper Element Air Cleaner ( Ii ) Restriction Indicator / Vacuum Indicator ( Iii ) Optimised Turbocharger ( Iv ) Intake Manifold ( V ) Exhaust Manifold ( Vi ) Silencer Mufflerand ( Vii ) Stainless Steel Exhaust Flexible Coupling ( C ) Cooling System Comprising ( I ) Radiator To Suitambient Conditions ( Ii ) Cooling System Piping ( Iii ) Thermostat ( Iv ) Pressure Cap ( V ) Coolant Inhibitor And ( Vi ) Engine Driven Fan 42 ( D ) Fuel System Comprising ( I ) Fuel Pump -Low Pressure Type ( Ii ) Injectors ( Iii ) Cartridge Paper Filters Primary And Secondary For Fuel ( E ) Governor :- Engine Electronic Governor For A1 Governing Of Engine Speed From No Load To Full Load. ( F ) Lub Oilsystem :- ( I ) Plate Type Lub Oil Cooler ( Ii ) Filters-Lubrication Oil. ( G ) Electric Starting System Comprising ( I ) Electrical Starter - 12 Volts ( Ii ) Engine Driven Battery Charging Alternator ( Iii ) Cut Out And ( Iv ) Oneno Of 12 Volts Of 150 Ah Maintenance Free Battery With Suitable Connection Terminals And Leads For Proper Battery Connection ( H ) Engine Monitoring, Protection Anddiagnostics Relay Suitable To Display Following ( I ) Lub Oil Pressure ( Ii ) Coolant Temperature ( Iii ) Engine Speed ( Iv ) Hours Run ( V ) Battery Voltage, Battery Charging Voltage ( Vi ) Fuel Level In Percentage, ( Vii ) Ac Voltage 3 Phase ( Viii ) Current Ryb 3 Phase ( Ix ) Power Factor ( X ) Frequency ( Xi ) Kva ( Xii ) Kilowatt Andsuitable For ( I ) Start And Stop ( Ii ) Common Shutdown ( Iii ) High Coolant Temp Warning And Shutdown ( Iv ) Low Tube Oil Pressure Warning And Shutdown ( V ) Low Fuel Level Shutdown ( Vi ) Overspeed Shutdown ( Vii ) Alternator Protection ( Viii ) Over Voltage ( Ix ) Under Voltage ( X ) Over And Under Frequency ( Xi ) Over Current ( J ) Engine Fitted With Low Lube Oil Pressure ( Llop ) & High Water Temperature ( Hwt ) Safety Devices And Also Fitted With Requisite Temperature And Pressure Gauges. ( B ) Alternator :- Self Excited, Self Regulated Screen Protected Drip Proof Type With Class H Insulation Salient Pole Revolving Field Andelectronic Automatic Voltage Regulator For Voltage Regulation Of + 0.5% From No Load To Full Load, Standard Enclosure 415 Volt 50 Hz 4 Pole 62.5Kva Cap Complete As Per Is-13364-2 And Conf To Is-4722 Or Bs 2613-1970 All As Required Or Recommended By Manufactrurer. ( C ) Base Frame :-Made Of Ismc Fabricated And Welded Construction Channel Duly Painted For Mounting Engine And Alternator All As Per ManufacturerS Design Along With Specially Designed In Built Vibration Pads. 43 ( D ) Lt Control & Amf Panel:-Amf Panel Board Free Standing Floor Mounted Factory Made Outdoor Type Made Out Of Crca Sheet 3.15 Mm Thick Totally Enclosed, Weather Dust And Vermin Proof With Front Opening, 440 Volts 3 Phase 4 Wire 50 Hz Having Aluminium Bus Bar Of Suitable Capacityfor Three Phases And Neutral Duly Powder Coated With Coloured Heat Shrinkable Pvc Sheelves, Multifunctional Digital Controler Relay For Amf Operation And Display Of Electrical Parameters, Manual / Auto Start / Stop Facility, Two Nos Electrically Operated Contactor 4 Pole Of Suitable Capacity For Dg Set And Main Supply ( Auto Shifting Of Electrical Load Is Required ) , 100 Amps Mccb Fp -01 No For Load, And Suitable Protection Arrangements For Contactors Complete All As Specified, With On / Off Controller Indicator, Phase Indicators, Engine Start Push Button, Engine Stop Push Button And Fault Accept / Reset Push Button Including Battery Charger Comprising Transformer, Rectifier, Resistance, Dc Volt Meter Dc Amp Meter And Charge Rate Selector Switch, All Accessories Prewired With Suitable Size Copper Conductor Cable Or Strip All As Required Or Recommended By Manufacturer. ( E ) Acoustic Enclosure ( Canopy ) :- Shall Conform To Central Pollution Control Board ( Cpcb ) Norms Of 75 Dba At One Metre Under Free Field Conditions, Having Air Inlet Louvers Specially Designed To Operate At Rated Load Even At Ambient Conditions On Air Inlet Temperature, Powder Coated For Long Lasting Service Life And Superior Finish With Uv Resistant Powder Coating To With Stand Extreme Environments, Designed To Have Minimum Ease For Unloading & Shifting , I.E With Central Lifting Facility, Rust Free Hardware Made Of Stainless Steel, Insulation Material To Meetis:8183 Specifications. ( F ) Fuel Tank :- Draw Out Type Integral Fuel Tank Made Of Ms Sheet ( Duly Painted ) Of Capacity Min 200 Ltrs Or As Recommended By Manufacturer With Level Indicator In Ltrs, Provided With Drain Plug And Air Vent / Breather And Inlet And Outlet Connections. ( G ) Foundation :- Size And Type Of Pcc Platform For Mounting Dg Set And Amf Panel Required To Be Constructed As Per ManufacturerS Specification Or As Recommeded By Engr - In - Charge. ( H ) Arrangement Of Pol For Testing Of Dg Set Done By The Contractor And Rates Deemed To Be Included In Quoted Rate.J ) Spares And Tools Will Be Supplied By Contractor. 44 Total Amount Of Credit I.E, Rs 192218.00As Per Sch Of Credit ( Sch A Part-Xvi ) Shall Be Deducted From The Total Amount Of Boq To Arrive At Contract Sum.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-10-2023 corrigendum7 Other 16-10-2023
2 04-10-2023 Corrigendum7 Other 16-10-2023
3 06-10-2023 corrigendum Other 16-10-2023
4 06-10-2023 corrigendum8 Other 16-10-2023
5 08-09-2023 corrigedum2 Date 22-09-2023
6 09-09-2023 corrigendum3 BOQ 22-09-2023
7 15-09-2023 corrigendum4 Date 30-09-2023
8 16-10-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-10-2023
9 23-09-2023 corrigendum5 Date 07-10-2023
10 26-08-2023 corrigendum1 Date 15-09-2023
11 30-09-2023 corrigendum6 Date 16-10-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 610000.0 /-
Tender Value
INR 5.70 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail