Repair Of Wiring And P / O Ei At Staff Quarter Maternity Home, C-Block Defence Colony ( Ipp-Viii ) . 1 Od3515 / 2023-2024:Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 2 Od3516 / 2023-2024:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 3 Od3517 / 2023-2024:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 4 Od3518 / 2023-2024:Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 5 Od3519 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 6 Module ( 200Mmx75mm ) . 6 Od3521 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 8 Module ( 125Mmx125mm ) 7 Od3520 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 12 Module ( 200Mmx150mm ) 8 Od3522 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 5 / 6 A Switch 9 Od3523 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 A Socket Outlet 10 Od3524 / 2023-2024:Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 11 Od3525 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 12 Way , Double Door 12 Od3528 / 2023-2024:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 13 Od3530 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required Single Pole 14 Od3529 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 A 15 Od3531 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 A 16 Od3532 / 2023-2024:Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 17 Od3534 / 2023-2024:Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire 18 Od3537 / 2023-2024:Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 19 Od3538 / 2023-2024:Installation Of Exhaust Fan In The Existing Opening , Including Making Good The Damage, Connection, Testing , Commissioning Etc.As Requiredup To 450 Mm Sweep 20 Od3539 / 2023-2024:Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 21 Od3540 / 2023-2024:Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 22 Od3543 / 2023-2024:Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 23 Od3544 / 2023-2024:Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 24 Od3545 / 2023-2024:Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.250 A, 36Ka, Fpmccb 25 Od3546 / 2023-2024:Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.125 A, 36Ka, Fpmccb 26 Od3547 / 2023-2024:Earthing With Gi Earth Pipe 4.5 Metre Long , 40 Mm Dia Including Accessories, And Providingmassonary Encloser With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal / Cock And Salt As Required. ) 27 Od3549 / 2023-2024:Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 28 Od3548 / 2023-2024:Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 29 Od3550 / 2023-2024:Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia ( Nominal ) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. 30 Od3844 / 2023-2024:Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. Group A 31 Od3845 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Up To 35 Sqmm 32 Od3846 / 2023-2024:S / L Of Following Size Dwchdpepipe Isi Marked Along With All Accessories Like Socket , Bend , Couplers Etc.Conforming To Is 14930 , Partii Complete With Fittingand Cutting , Jointing Etc .Direct In Ground ( 75 Cm Below Ground Level ) Including Excavationand Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc, Complete As Required ( A ) 63Mm Dia ( Od-63Mm Id -51Mm Nominal ) . 33 Od3847 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 34 Od3966 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group A 35 122.1.47:Supply Of 250 Mm ( 10 Inch ) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutter Blades Etc. As Required. 36 Od3551 / 2023-2024:Supply Of 1200 Mm Sweep 50 Watt, Energy Saver Isi Marked Bee 5 Star Rating Ac Ceiling Fan Suitable For 230 V, 50 Hertz Ac Supply Without Regulator With Blades , Downrod Etc. Complete As Required. 37 122.1.44:Supply Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 38 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 39 122.1.30:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-4C*25 Sqmm 40 122.2.83:Supply, Installation, Testing And Commissioning Of Power Distribution Board Made Out Of 1.6 Mm Sheet Steel, Epoxypowder Coated , Specially Designed Al Bus Bar 400A To 630A With Heat Shrinkcable Colour Coated Sleeves Suitable For Accommodating Mccbs / Mcbs / Isolators As Incoming And Outgoing As Required ( Without Mccbs / Mcbs / Isolators ) Complete With Digital Meter Module, Including Voltmeter Ammeter With Selector Switch, Cts Control Fuse And Indicating Lights Including Connections Etc. As Required ( Conforms To Is:8623 ) 41 122.2.156. ( B ) :P&F Following Sizes Of Pvc Insulated & Pvc Sheathed Copper Conductor 3 Core Submersible Cable Confirming To Is.694 / 1990 Etc. As Reqd. 3X 4 Sq.Mm 42 122.2.155. ( C ) :Supply, Installation, Testing And Commissioning Of Cubical Type Control Panel Board For Single Phase & Three Phasesubmersible Pumping Set Of Following Rating Complete With Contactor, Relay , Mcb , Condenser , Voltmeter, Ammeter And Indication Lamp Etc Includingconnections Etc As Reqd. 3 Hp ( Three Phase ) 43 122.2.150. ( C ) :Supply, Lowering And Fixing Following Size Of G.I. Pipe ( M-Class ) I / C Cutting Threading On Both Sides Etc. Isi Marked Etcas Reqd. 40Mm ( Nominal Bore ) 44 122.2.154B. ( B ) :Supplying, Lowering, Testing And Commissioning Of Vertical Type, Multistage, Totally Enclosed Water Filled Deep Well Submersible Pumping Set Complete I / C Connection Etc. As Reqd. Single Phase 3.0 Hp Having Discharge Of 100 Lpm Approx. At 52 M Head 45 122.1.2:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*6 Sqmm 46 122.2.142. ( B ) :Comprehensive Amc ( Annual Maintenance Contract ) For Repair Andmaintenance Of Tube Wells Installed At Various Municipal Parks For Depth Of 50 Meters To 100 Meters. Cost For One Tube Wells With Submersible P / Set Etc Of Upto 3 Hp