|
| 1 | SUPPLY OF ITEMS |
| 2 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 3 | Stone Pad (300x300x75mm) |
| 4 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
| 5 | Aerial Bunched XLPE Cable 1X25 (Ph) + 1X16 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
| 6 | LT XLPE cable 4x16 Sq mm |
| 7 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 8 | ACSR Weasel Conductor |
| 9 | ACSR Rabbit Conductor -Jumpering Works |
| 10 | Aluminium binding wire - 6 SWG |
| 11 | 11KV Fuse Set (Drop out) |
| 12 | 11KV TPMO |
| 13 | 25 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
| 14 | LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipmen . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24) |
| 15 | 9 KV LA , 5 KA (Distribution Class) |
| 16 | Earthing Coil connected with nutbolt using Bentonite Powder |
| 17 | GI Flat 25X3 for Earthing |
| 18 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 19 | G.I. Barbed Wire |
| 20 | G.I. Wire No. 16 SWG for binding |
| 21 | G.I. Wire 6 SWG |
| 22 | G.I. Wire 8 SWG |
| 23 | 11 KV Disc Fitting T & C type |
| 24 | 11 KV Polymer Disc Insulators45 KNT&C Type |
| 25 | 11 KV Pin Insulator Polymer Type as per TS |
| 26 | Dead End clamp (Insulated) |
| 27 | End Cap for AB cable |
| 28 | Suspension clamps (Insulated) |
| 29 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
| 30 | Insulating Piercing Connector (16-95 sq.mm) |
| 31 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
| 32 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
| 33 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 34 | PG Clamp for Rabbit |
| 35 | GI Stay Wire 7/10 SWG |
| 36 | HT Guy Insulator |
| 37 | LT Guy Insulator |
| 38 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
| 39 | HT Stay Clamp as per approved drawing-11 KV |
| 40 | LT Stay Clamp as per approved drawing |
| 41 | Pre-fabricated galvanised steel items (zinc 610gms/sqm), like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings,Tea off, guarding channels, back clamp, DT\"s Structure etc made of GS Channels , GS angle , GS flats (50x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
| 42 | GS Nuts, bolts and washers as per technical specification, approved drawings and scope of work. |
| 43 | Eye Bolt |
| 44 | Jointing sleave -ACSR Weasel |
| 45 | 11 KV Danger Board |
| 46 | 11 KV Number Plate |
| 47 | Sign Board as per TS and Approved Drawing |
| 48 | ERECTION PART |
| 49 | Survey , Erection, Testingand commissioning of 11 Kv Line(Complete Work in all respect) |
| 50 | Route survey and pole spotting for 11 KV line |
| 51 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 52 | ACSR Weasel Conductor |
| 53 | Stone Pad (300x300x75mm) |
| 54 | Pre-fabricated galvanised steel items (zinc 610gms/sqm), like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings,Tea off, guarding channels, back clamp, DT\"s Structure etc made of GS Channels , GS angle , GS flats (50x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
| 55 | GS Nuts, bolts and washers as per technical specification, approved drawings and scope of work. |
| 56 | G.I. Wire 6 SWG |
| 57 | G.I. Wire 8 SWG |
| 58 | Eye Bolt |
| 59 | G.I. Wire No. 16 SWG for binding |
| 60 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 61 | 11 KV Pin Insulator Polymer Type as per TS |
| 62 | 11 KV Polymer Disc Insulators45 KNT&C Type |
| 63 | 11 KV Disc Fitting T & C type |
| 64 | PG Clamp for Rabbit |
| 65 | Aluminium binding wire - 6 SWG |
| 66 | Jointing sleave -ACSR Weasel |
| 67 | 11 KV Danger Board |
| 68 | G.I. Barbed Wire |
| 69 | Earthing Coil connected with nutbolt using Bentonite Powder |
| 70 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
| 71 | HT Guy Insulator |
| 72 | GI Stay Wire 7/10 SWG |
| 73 | HT Stay Clamp as per approved drawing-11 KV |
| 74 | 11 KV Number Plate |
| 75 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 76 | Erection, Testingand commissioningof 11/0.433 KV three phase Transformer sub-station -25 KVA(Complete Work in all respect) |
| 77 | 25 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
| 78 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 79 | Stone Pad (300x300x75mm) |
| 80 | Pre-fabricated galvanised steel items (zinc 610gms/sqm), like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings,Tea off, guarding channels, back clamp, DT\"s Structure etc made of GS Channels , GS angle , GS flats (50x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
| 81 | GS Nuts, bolts and washers as per technical specification, approved drawings and scope of work. |
| 82 | 11 KV Polymer Disc Insulators45 KNT&C Type |
| 83 | 11 KV Disc Fitting T & C type |
| 84 | 11 KV Pin Insulator Polymer Type as per TS |
| 85 | 11KV TPMO |
| 86 | 11KV Fuse Set (Drop out) |
| 87 | 9 KV LA , 5 KA (Distribution Class) |
| 88 | LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipmen . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24) |
| 89 | LT XLPE cable 4x16 Sq mm |
| 90 | G.I. Barbed Wire |
| 91 | ACSR Rabbit Conductor -Jumpering Works |
| 92 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
| 93 | HT Guy Insulator |
| 94 | GI Stay Wire 7/10 SWG |
| 95 | HT Stay Clamp as per approved drawing-11 KV |
| 96 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 97 | GI Flat 25X3 for Earthing |
| 98 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 99 | Erection, Testingand commissioning of New LT Line With AB Cable(Complete Work in all respect) |
| 100 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 101 | Stone Pad (300x300x75mm) |
| 102 | Aerial Bunched XLPE Cable 1X25 (Ph) + 1X16 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
| 103 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
| 104 | Pole Clamps with with I-Hook for laying ABC |
| 105 | Dead End clamp (Insulated) |
| 106 | Suspension clamps (Insulated) |
| 107 | End Cap for AB cable |
| 108 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 109 | Insulating Piercing Connector (16-95 sq.mm) |
| 110 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 111 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
| 112 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
| 113 | Earthing Coil connected with nutbolt using Bentonite Powder |
| 114 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
| 115 | LT Guy Insulator |
| 116 | GI Stay Wire 7/10 SWG |
| 117 | LT Stay Clamp as per approved drawing |
| 118 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 119 | Installation of Sign Board with as per TS and Approved Drawing |
| 120 | Sign Board as per TS and Approved Drawing |