| 1 | M & L for comprehensive maintenece and servicing ofSplit type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust frombody with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor,fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioningall as specified and directed by Engineer-in-Charge. |
| 2 | All as per Item No.1 above, but for Water cooler/Deep freezer/Refrigerator of any type and any capacity(Note for sl item No. 1 & 2:Spares parts replaced shall be measured & paid saperately under relevant items here-in-below) |
| 3 | Supply only starting capacitor of suitable capacity for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed. |
| 4 | Supply onlyblower motor capacitor of suitable capacity all as specified and directed. |
| 5 | Supply only starting relay suitable for water cooler,AC, and refrigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed. |
| 6 | Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in single phase 230 volt all as specified and directed. |
| 7 | Supply only themostat switch suitable for Air conditioner,water cooler, deep freezer and refrigerator operated on single phase 230 volts supply all as specified and directed. |
| 8 | Supply only drier filter for AC, water cooler and refrigerator. |
| 9 | Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed. |
| 10 | Supply Only capillary tubes for the following :- |
| 11 | Air Conditioner1.5 ton /2 ton and Water cooler 40 to 150 ltr |
| 12 | Refrigerator & Deep freezer upto 400 ltr |
| 13 | Supply only indoor fan motor of split type AC of any capacity |
| 14 | Supply OnlyCondensor fan motor as per existing make and capacity for the following as under all as specified and directed by Engineer In Charge |
| 15 | Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton |
| 16 | Window type ACof 1.0Ton/1.5Ton/2.0Ton |
| 17 | Water Coolerof 40-80 Ltr and deep freezer upto 400Ltr |
| 18 | Water Coolerof 120-150Ltr |
| 19 | Supply only blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified and directed. |
| 20 | Supply, install, test & commissioning hermatically sealed new compressor for Split type AC of capacity 1.5TR duly charged withfresh freon gasetc complete all asspecified/directed by Engineer-in-Charge including taking down old u/s compressor.Make:- Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site. |
| 21 | All as per item No.13 above, but for split type AC of capacity 2.0 TR |
| 22 | All as per item No.13 above,but for Window type AC of capacity 1.5TR |
| 23 | All as per item No.13 above,but forWindow Type AC of capacity 2.0TR |
| 24 | All as per item No.13 above, but for Water Cooler of capacity 40 to 80Ltr |
| 25 | All as per item No.13 above, but for Water Cooler of capacity 120 to 150Ltr |
| 26 | All as per item No.13 above, but for Refrigerator 165 to 160Ltr Capacity |
| 27 | All as per item No.13 above, but for Refrigerator 286 to 310Ltr Capacity |
| 28 | All as per item No.13 above, but for deep freezer 298 to 310 ltr capacity |
| 29 | M & L for detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge |
| 30 | All as per item No. 22 above, but of water cooler, refrigerator & deep freezer of any type and any capacity |
| 31 | Supply and replace remote control unit of Split type AC1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge |
| 32 | Supply only Electronic PCB unit for main control panel of Split type/Window type AC of any capacity all as specified and directed. |
| 33 | M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making functional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enamelled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:- |
| 34 | 1 KVA |
| 35 | 2 KVA |
| 36 | 4 KVA |
| 37 | 5 KVA |
| 38 | M&L for dismantling of existing unserviceable power UPS for repairs andreplacement of unserviceable parts likerelays , electronic voltage sensor circuits, meters, micro switch , indication light RC fitters, rectifiers, transformers as per existing capacity and specifications and other connected items for making functional as per the entire satisfaction of Engr-in-charge and testing complete for Capacity upto 5KVA |
| 39 | Disconnecting electrical / mechanically and lowering to the ground for repairing / over hauling the desert cooler including replacement of canvas grass / wood wool pads to make it fully functional including replacement of unserviceable/defective spare parts, transportation to and fro, re-installation and testing on completion to the entire satisfaction of Engineer -in - chargeNote : Spares replaced will be measured and paid under seperate Item |
| 40 | Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge. |
| 41 | Supply only fan motor of desert cooler of any capacity includingsupporting legs , nuts and bolts etc. |
| 42 | Supply only fan blade with bush for desert cooler motor |
| 43 | Supply only selector switch/rotory knobfour way suitable for desert cooler as per existing size and make |
| 44 | Supply only electronic control circuit board (PCB) as per existing type for desert cooler. |
| 45 | Supply only swing motor for air cooler |
| 46 | S & F in repair Metal Plug Tops for 2 Pin and earth socket AC Box of capacity 240V, 20 A all as specified and directed |
| 47 | Supply OnlyPVC flexible pipe 25 mm dia as in drain pipe suitablefor water cooler outlet |
| 48 | S&F in repair connecting sheet metal enclosure with two pin and earth plug and socket complete, with one double pole MCB20 Amp Make : Havells/ Standard/ HPL. |
| 49 | S&F in repairs Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore. |
| 50 | S & F in repair Push tap Self closing taps of size 15 mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler |
| 51 | Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers including taking down old pipe |
| 52 | M&L for wiring for circuit /sub main wiringwith earth wire of size 2x 4.0sqmm + 1 x 2.5sqmm of FR PVC insulated copper conductor, single core cable in surface drawing in and includingPVCcasing capping. |
| 53 | M&L for wiring for circuit /sub main wiringwith earth wire of size 2x 2.5sqmm + 1 x 1.5sqmm of FR PVC insulated copper conductor, single core cable in surface drawing in and includingPVCcasing capping. |
| 54 | Taking down unserviceable/damaged Sub main wiring any type any size including continuous earth wire, conduit/casing and making good disturbed surfaces of walls/ceiling matching with existing tint. |
| 55 | M&L in repairs point wiring for light/fan/Bell with FRLS cable 2.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/capingwith all accessories and 2.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly inclPVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators,etc complete all as specified and directed for multipin 15 amps socket outlet flush type on independent board controlled by one switch & making goodto disturbed surface of wall etc all as specified and directed. |
| 56 | Material and labour for cross arms, bracing supports, clamps fabricated out of structural steel such as ISMC, angle iron, flat iron sections including hot galvanised nuts & bolts, washers for single and two pole structure welding,bending cold or hot, drilling holes for bolts, in any shape or size as specified and including of one under coat and finishing coat with aluminium paint over a coat of red oxide primer.Note: Fabrication,welding and transportation is inclusive in the rate itself. Also, including excavation returning, filling, removing (if required) and connected jointing and fabrication work all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.wall mounted including taking down old one. |
| 58 | M & L for repair/replacement tostainless steelwaste water tray including welding, polishing, riveting, provision of fixing screws and refixing. |
| 59 | S & F in repair for gaskets for top cover forwater cooler of any capacity and make as per site requirement. |
| 60 | M & Lforreplacement damage cooling coil for refrigerator of capacity 210/300 ltrs |
| 61 | M & L for replacement damage condensor coil for refrigerator of capacity 210/300 ltrs |
| 62 | Supply only door switch for refrigerator of any type and any capacity |
| 63 | Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator |
| 64 | Supply only fridge door as per existing make and type for refrigerator |
| 65 | Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs |
| 66 | S&F in replacement galvanised, corrugated mild steel sheeting of 0.50 mm thickness having tensile strength of min 250 Mpa fixed with coach screws and ashers, in roofs, walls etc.complete all as specified by EIC. |
| 67 | M&L for PCC (1:4:8) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc. |
| 68 | M&L for printed letters, figures or symbols (i.e comma, hyphen, stops, etc) with super glue to stick to any surface (weather proof) of size 2 cm each in black colour and arial font and bold letters.Note: Number of letters,symbols may vary machine to machine, hence rate quoted should be of per machine basis. The contractor shall get the letters,symbols approved by EIC before sticking it to the machines. |
| 69 | M & L for carry out routine maintenece and servicing of Package type air conditioner of capacity 8.5TR & 11TR including removing the dust frombody with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checkingfunction of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT Control panel, VFDs,electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioningall as specified and directed by Engineer-in-Charge.Note: 1. Spares parts replaced shall be measured & paid under saperate item |
| 70 | Supply only V-Belt Type 13x813A 32A840EL for Blower fan of Package AC Unit of Capacity 8.5TR/11TR |
| 71 | Supply only relay HP & LP for package type AC plant of capacity 8.5TR |
| 72 | Supply only relay HP & LP for package type AC plant of capacity 11TR |
| 73 | Supply only condensor fan motor , 230V,50Hz 920rpm 2 HP for package type AC,Model: 14B606A1E/2L-FP7 Make: Micro Instrument Co. or equivalent |
| 74 | Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 Volt with auxilary contact 1NO + 1NC, having coil voltage 380 to 400 Volts Make Simens cat refC4NE22 or equivalent of L &T/Havells. |
| 75 | Supply, fixing and connecting in replacementIntigrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner. |
| 76 | Supply, fixing and connecting in replacementIntigrated circuit board with all electronic components suitable for 11 TR capacity Carrier Pakage type Air conditioner. |
| 77 | Supply, fixing and connecting in replacement SPPR Circuit board suitable for 8.5TR/11TR cap Package AC of Make Carrier. |
| 78 | Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 11TR suitable for package type AC |
| 79 | Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 4.25TR suitable for package type AC |
| 80 | Supply only thermostatic expansion valve for package type AC plant of capacity 8.5/11TR |
| 81 | ..do.. all as per Item No.1 above, but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ductable type ACindoor and outdoor unit of capacity 8.5TR complete all as specified and as direted by Engineer In Charge. |
| 82 | Supply and fixing of condensate drain pump of ductable type AC of capacity8.5TR |
| 83 | Supply and fixing of Condensor fan motor suitable for ductable type AC of capacity8.5TR |
| 84 | Supply and fixing of fan blade suitable for outdoor unit of capacity 8.5TR ductable AC |
| 85 | Supply and fixing of Blower Motor suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 86 | Supply and fixing of Direct driven forward curved type centrifugal Blower fan suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 87 | Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 88 | Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 8.5TR for carrier make ductable Air conditioner |
| 89 | Supply only thermostatic expansion valve for ductable type AC plant of capacity 8.5TR |
| 90 | All as per Item No.1 above, but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ceiling Mounted Cassette type ACindoor and outdoor unit of Capacity 4.0TR complete all as specified and as direted by Engineer In Charge. |
| 91 | M & L for replacement of condensate drain pump assembly of cassette type AC of capacity 4.0TR |
| 92 | Supply and fixing ofSensor unit for water pump of carrier make casset type ACindoor unit (as per existing). |
| 93 | Supply and fixing of Condensor fan motor suitable for cassette type AC of capacity 4.0TR |
| 94 | Supply and fixing ofFan blade made of HD PVC suitable for Carrier make assette type AC of capacity 4.0TR outdoor unit incl lock nut. |
| 95 | Supply and fixing ofBlower Motor/Indoor fan motorsuitable for Carrier Make Cassette type AC of capacity 4.0 TR |
| 96 | Supply and fixing ofElectronic PCB Kit for control panel suitable for Carrier Make Cassette type AC of capacity 4.0 TR |
| 97 | Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 4.0TR for carrier make Cassette type Air conditioner |
| 98 | Supply and fixing of three phase 3Ph, 415V, 50Hz overload protection relay suitable for ductable/casstte AC. |
| 99 | Supply and fixing ofAir brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR Cassete type Air Conditioner.Make: Siemens/C&S/L&T/BCH |
| 100 | Supply and fixing ofsingle phase preventor relay suitable for ductable/casstte AC. |
| 101 | Supply only thermostatic expansion valve for cassettee type AC plant of capacity 4 TR |
| 102 | All as per Item No. 1 above, but for carry out repair/maintenance of 3Phase, 415V, 50HzWalk in Chiller and Coolerindoor and outdoor unit of Capacity 3.0 TR complete all as specified and as direted by Engineer In Charge. |
| 103 | M & L for replacement of condensate drain pump assembly of capacity 3.0TR |
| 104 | Supply and fixing ofSensor unit for water pump of carrier make indoor unit (as per existing). |
| 105 | Supply and fixing of Condensor fan motor suitable for of capacity 3.0TR |
| 106 | Supply and fixing ofFan blade made of HD PVC suitable for Carrier make of capacity 3.0TR outdoor unit incl lock nut. |
| 107 | Supply and fixing ofBlower Motor/Indoor fan motorsuitable for Carrier Make of capacity 3.0 TR |
| 108 | Supply and fixing ofElectronic PCB Kit for control panel suitable for Carrier Make of capacity 3.0 TR |
| 109 | Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 3.0TR for carrier make. |
| 110 | Supply and fixing of three phase 3Ph, 415V, 50Hz overload protection relay suitable for 3.0 TR walk in chiller |
| 111 | Supply and fixing ofAir brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 3.0 TR walk in chiller.Make: Siemens/C&S/L&T/BCH |
| 112 | Supply and fixing ofsingle phase preventor relay suitable for Walk in chiller. |
| 113 | Supply only thermostatic expansion valve for walk in chiller type AC plant of capacity 3 TR |
| 114 | M & L for detecting the gas leakage,rectifyiong the defects including repair to condenser coil/evaporator coil by means of welding soldering etc vacumizing,testing complete for the 11 TR pakage type AC . |
| 115 | All as per Item No.106 above, but for 4.25TR Compressor of 8.5TR Package type AC plant. |
| 116 | All as per Item No.106 above, but for 8.5TR Compressor of ductable type AC. |
| 117 | All as per Item No.106 above, but for 4.0TR Compressor of ceiling mounted ductable type AC. |
| 118 | All as per Item No.106 above,but for 3.0TR Compressor of Walk in chiller and cooler |
| 119 | S&F in replacement copper tubing 5/8\" as specified and directed by E-in-C. |
| 120 | S&F in replacement copper tubing 1/4\" as specified and directed by E-in-C. |
| 121 | S&F in replacement copper tubing 3/8\" as specified and directed by E-in-C. |
| 122 | Supply & charging ofrefrigerant gas R-22/404/134a/32 for charging in any summer cooling appliances complete and checking of leakage, testing for proper functioningall as specified & directed by Engineer-in-charge. |
| 123 | M&L for cleaning of Package type AC and surrounding area by surface excavation upto 10 cm depth incl removing shrubs,grass,miniplants and other unwanted materials and levelling complete in soft/loose soil all as specified and directed. |
| 124 | Supply and fixing Integral LED Street Light Luminaire 50 W, 6500K comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe complete with accessories like GI pipe, wire, etc complete. Make : Havells/phillips all as specified here-in-after including taking down old fitting. |
| 125 | M&L for maintenance free grounding Solution set earthing comprising of Earthing rod, outer pipe in Gl and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. GI terminal size of 100x50x6mm with 2 Nos M8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr.The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition.The Earth pit cover Square 300×300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : U-PROTEC or equivalent in Ashlok earthings/JEF technology NOTE :- (a) Rates of boring 3 Mtr for earth electrode, GI strip 20×3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b) On testing, after, after completion, if the earth resistance <3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (C) Test certificate from the OEM has to be produced by the contractor for the material used in earthing |
| 126 | S & F in replacement of Solenoid valve for Walk in chiller AC suitable for 3 TR |
| 127 | S & F in replacement of Solenoid coil of suitable size for Walk in chiller AC suitable for 3 TR |
| 128 | S & F in replacement of strainer for4 to 11 TR Package type Acs/Ductable/Cassettee AC |
| 129 | S & F in replacement of unserviceable/leakage Service Valve suitable for4 to 11 TR capacity Package /Ductable/Cassette AC Plant. |
| 130 | S & F in replacement of unserviceable Solid state indicating lamps 230 Volt AC with RYB and green indication (LED type ) including adopter ring / washer and cable connection complete. Make: Altos |
| 131 | S&F in replacement of digital type temperature indicator including sensor and multicore copper cable ( Length of cable as per requirement ) |
| 132 | Supplying & laying in replacement insulating mat of size 2000x1000x12mm thick with ISI mark of LT side |
| 133 | S&F in replacement single phase preventer of model VSP D-1A/SP-3, Make : Minilec |
| 134 | S&F in replacement copper tubing 3/4\" for the package/Ductable/Cassettee/Walk in chiller AC of capacity 3 TR to 11 TR as specified and directed by E-in-C. |