| 1 | A. 3.3 kV H.T. Cable, control cables, End Termination (Heat shrinkable type)& Cable Laying (as TONODL Specifications) |
| 2 | Supplying, Laying, Testing & Commissioning of 3C x 150 Sq.mm, 3.3kV GRADE XLPE aluminium conductor steel armored cable in the existing masonry open duct/open surface/RCC/HUME pipe/Cable Tray as required. |
| 3 | Supplying and Making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3CX150 Sqmm., XLPE aluminium conductor cable of 3.3 KV grade as required. |
| 4 | Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3CX150 Sqmm., XLPE aluminium conductor cable of 3.3 KV grade as required. |
| 5 | Supplying, Laying, Testing & Commissioning of 3C x 95 Sq.mm, 3.3kV GRADE XLPE aluminium conductor steel armored cable in the existing masonry open duct/RCC/HUME pipe/Cable Tray as required. |
| 6 | Supplying and Making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3CX 95 Sqmm., XLPE aluminium conductor cable of 3.3 KV grade as required. |
| 7 | Coordination for NOC from Electrical Inspector: |
| 8 | The NOC from the Electrical Inspector after the completion of work is in the scope of the vendor. |
| 9 | B. Indoor HT Panels & Soft Starter Panels |
| 10 | 3.3KV H.T. SWITCHGEAR |
| 11 | Design, supply, installation, testing and commissioning(DSITC) ofExtendable type 3.3kV VCB Indoor HTswitchgear panel module consisting of 3nos.- Incomer feeders (2nos. for transformer & 1no. for DG set) and (6nos.- Outgoing feeders,1 nos.-Bus Coupler, 1 no.-Bus Riser, 2 nos.-Bus PT Panel) including 1 no.-Earthing Truck & all accessories conform to the relevant IS/IES 61439 standard and all breakers shall be with A/V/KWH meters and the necessary power pack shall be provided all incomers & outgoing cables shall be a top entry in the panel. Also having provision of Electromechanical interlocking with castle key and PLC logic controller. Scope includes manufacturing, transportation, loading, unloading, shifting to the final location, and interconnection between accessories mounted on HT VCB with the mounting of loose accessories supplied by the vendor. As per special conditions of the contract making good the damages caused complete as per the direction of the Engineer-in-charge. |
| 12 | INCOMER FEEDERS-3 Nos.(2 nos Transformer & 1 no. DG Set): 3.3 kV Indoor Electromechanically Draw out type VCB-800A, 26.3 kA/3 SEC, Busbar 1000A(Copper) & (CT 800-400/5-5-5A) for Transformer Protection Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel. |
| 13 | 1 no- Digital Multi functional Meter |
| 14 | 1 no- Power Pack for Electrical Closing Mechanism |
| 15 | 1 Set - Phase indicating lamps (R,Y,B), ON/OFF, Trip and Spring Charged. |
| 16 | 1 no- Emergency Trip Push Button. |
| 17 | 1 Set - Trip Circuit Healty Test Push Button with Indicating Lamp |
| 18 | 1 no - Trip/ Neutral/ Close switch |
| 19 | One-(1)- Master Trip Relay with Electrical Reset Facility Push button |
| 20 | One (1)- Numerical Relay (50/51,50N/51N, 27/59) |
| 21 | One (1)- 8-Window facia annunciator with accept, reset & test push button. |
| 22 | BUS COUPLER-1 no. : 3.3kV Bus-Coupler Indoor Electromechanically Draw out type VCB consisting of Breaker-800A, 26.3 kA/3SEC & CT (800-400/5-5-5A) for bus coupler. Relays are to be installed on the panel, Multi-function Meter is to be installed above the panel, Energy meter is to be installed on the panel. |
| 23 | BUS PT -2 Nos.: 800 A 3.3kV, 2 Core, Single Phase, IVT (3.3/v3 kV / 110/v3-110/v3V), 3nos in a set, in a separate draw out the chamber with Digital Voltmeter inside Control Room separately for Bus-1 & Bus-2 plug-in type with disconnector along with PT removal trolly. |
| 24 | OUTGOING FEEDERS-6 Nos.(2 nos APFC-1&2, 2nos Soft starter panels and 2 nos spares): 3.3kV Indoor Electromechanically Draw out type Air Insulated switchgear consisting of Breaker-630A, 26.3kA/3SEC, Busbar-1000A (Copper), CT (600-300/5-5-5A) for Feeder protection Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel. |
| 25 | 1 no- Digital Multi functional Meter |
| 26 | 1 no- Power Pack for Electrical Closing Mechanism |
| 27 | 1 Set - Phase indicating lamps (R,Y,B), ON/OFF, Trip and Spring Charged. |
| 28 | 1 no- Emergency Trip Push Button. |
| 29 | 1 Set - Trip Circuit Healty Test Push Button with Indicating Lamp |
| 30 | 1 no - Trip/ Neutral/ Close switch |
| 31 | One-(1)- Master Trip Relay with Electrical Reset Facility Push button |
| 32 | One (1)- Numerical Relay (50/51,50N/51N, 27/59) |
| 33 | One (1)- 8-Window facia annunciator with accept, reset & test push button. |
| 34 | Coordination for NOC from Electrical Inspector: |
| 35 | The NOC from the Electrical Inspector after the completion of work is in the scope ofvendor. |
| 36 | Panel as above |
| 37 | Design, supply, installation, testing, and commissioning(DSITC) of 3.3 kV FCMA type Soft Starter for 225kW Pump sets (Indoor Type) with Vacuum bypass Contactor, C.T, Ammeter, RTD\"s, PLC, Current Transducer and Indicating Lamps including control circuit and Local Control Switch to be connected at Line Side of the H.T. Motor. Also having 5 years of Extended Warranty after DLP(1st yr warranty). |
| 38 | Coordination for NOC from Electrical Inspector: |
| 39 | The NOC from the Electrical Inspector after the completion of work is in the scope of vendor. |
| 40 | Design, supply, installation, testing, and commissioning(SITC) of 3-stages 3.3kV 150 kVAR 3- Ph APFC Panel (Indoor Type) conforming to the relevant IS/IES standard and as per special conditions of the contract making good the damages caused complete as per the direction of the Engineer-in-charge. |
| 41 | Coordination for NOC from Electrical Inspector: |
| 42 | The NOC from the Electrical Inspector after the completion of work is in the scope of the vendor. |
| 43 | C. HT DG Set & Other Accessories |
| 44 | 3.3kV DG Set |
| 45 | 750 KVA 3.3KV DG set comprising of : engine developing suitable power at 1500 rpm complete with standard accessories coupled to an alternator mounted on a channel iron base frame, Under NTP conditions of BS :5514 with an overload capacity of 10% for one hour in every 12 hours operation. |
| 46 | Make: Perkins Engine model 4006D-E23TAG2 or equivalent of Cummins/caterpillar/mitsubishi /MTU |
| 47 | Cooling system: radiator cooled engine, mounted blower fan , engine mounted water pump, and thermo stat.Initial filling of corrosion inhibitor coolant by vendor |
| 48 | Fuel system: Two nos of 990 ltr capacity fuel tanks with connected pipes lines/hoses, stand for two fuel tanks, overflow pipes, drain valves, air vent valves, strainers openings for inspection and cleaning with cover, level indication in the tank with scale to indicate the fuel stored, common outlet of two tanks should be connected to the engine), full flow spin-on filters to the engine, fuel pump, injectors. The initial filling of fuel (high-speed diesel). Vendor to confirm DG foundation with AVM Pad as per BIS, lubricating system: oil pump, strainer, spin-on filter, pipes, intimate lube grade, the capacity of the sump, initial tank filling of lube oil & Diesel by the vendor. |
| 49 | Air intake system: Dry type filter , air manifold with necessary connection ,turbo charger with after cooler . |
| 50 | Exhaust system : 300 mm dia exhaust pipe, manifold, stainless steel flexible / pipe , canopy , residential silencer .heat resistance epoxy painting coat on pipe , insulation and hanger , support structurer starting from engine to side DG room ( aluminium cladding, chiken mesh mineral wool up to canopy, etc ), provision for temperature and pressure, test and measurement for checking compliance with statutory requirement . |
| 51 | PCB: stack of required height as per pcb norms has to be provided.Emission shall be with in norms specified by Pollution control board and environment protection rules . Room design to be given by vendor.Room construction by BHEL . |
| 52 | Governing system : electronic governer controller |
| 53 | Starting system :DC starter motor , battery charging alternator with in built regulator. suitable stand,suitable nos. of charged maintainace free batteries , with cable leads and terminal holders. battery make :exide/ amaron/cummins pulse / amco/prestolite/sf |
| 54 | Spare parts of filters Includes Lub Oil , Fuel & Air filter to be replaced up to 1000 hrs at free of cost whenever required. Motor driven prime pump for lube oil Cylinders in the Engine is Maximum of 12 Numbers. Fly wheel housing,flexible coupling,coupling guard, base frame : sturdy, fabricated, welded costruction, channel iron frame for mounting the above engine and below alternator . Battery charger from mains 230V AC Starting. |
| 55 | Alternator: |
| 56 | Power Rating (KVA) - 750 KVA, Output Voltage & Frequency -3.3K V, 50 Hz Frequency RegulationPower Factor (lagging) - 0.80No.of Phases - 3 Phase + NeutralSelf regulated,brushless, horizontal mounted , single shaft with double bearing. Automatic Voltage Regulator suitable for parallel operation of generators. Voltage Regulation (+/-1%)- no load to full load. Insulation Class H. Enclosure: Make Kirloskar/Stamford/ToyoDenki/Leroysomer/ Sterling |
| 57 | Panel: |
| 58 | Supply and Installation AMF Panel with 01 No. I/C 800 Amp VCB. (Make: ABB/Siemens/Schneider) for 1 x 750 KVA DG Set. Supply and Installation NGR & NIS Panel. |
| 59 | Microprocessor based control panel for Alternator and Engine for monitoring, metering, control and protection against fault: |
| 60 | All control cables & their wiring are in the Scope of the Vendor. Battery Voltage Sensing & Monitoring and charging current. Push Buttons for Manual Start / Stop , Manual Test -Mode Selector Switch, Annunciation, Alarm & Trip Features, Indications for DG \"ON/OFF”, Indications for MAINS \"ON\" for load, Indications for Over Current & Earth Fault, Coolant temp., LOP, RPM indication, Service hour meter, Protection, High Water Temperature, Low Lube Oil Pressure, Over / Under speed, Air Filter Clog Indicator, Starting Failure, Generator Overload , Battery Voltage Low. |
| 61 | Errection & Commissioning: |
| 62 | Supplier shall be responsible for carrying out the Erection, start up testing and commissioning of the new DG Set required technical personnel and labour for the same shall be provided by the vendor. Tools, tackles, required for the same shall be a arranged by the vendor. Erection of the Stack and thermal insulation of the exhaust system is also the responsibility of the vendor. |
| 63 | Operating Condition : |
| 64 | The DG Set should work trouble free and efficiently under following operating conditions: |
| 65 | Ambient Conditions: Temperature = 20 to 50 degree Celsius Relative Humidity = 95% max. |
| 66 | Guarantee: |
| 67 | The DG set shall be guaranteed for a period of 24 months from the date commissioning or 5000 hrs from the date of commissioning whichever occurs earlier. |
| 68 | Coordination for Approval from Statutory Authority: |
| 69 | Coordination for Approval from Statutory Authority all Input like Drawing & other Supporting Document & Coordination with the agency Vendor Scope SEB, CEIG,CEA,CPCB etc approvals in the scope of the vendor. |
| 70 | DG SET AS ABOVE |
| 71 | D. Indoor LT Panels |
| 72 | Supply, installation, testing and commissioning of cubicle type sectionalise, front operated top entry dust and vermin proof M.V. Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrinkable PVC sleeve, base channel, wiring with a space heater, thermostat and control MCBs shall be provided for all vertical sections of main LT Panel, all hinged door shall be earthed through2.5 sq mm tinned braided, the incoming and outgoing feeders shall be accommodated in a modular arrangement, detachable gland plates, adequate size cable alley, Signwriting, Painting, Earthing, Numbering, Danger plate, including PVC insulated copper FRLS wires of minimum 1.5 sq.mm & 2.5 sq.mm for CT\"s, etc. with all accessories including interconnections, earth bus, Surge Protection Device(SPD) etc. as required.(All the incomers & outgoings of the panel must be mounted with RS 485 communication port for BMS Compatibility) (As per approved SLD) |
| 73 | Main Distribution Board(MDB) |
| 74 | One (1)Incomer from 100kVA 33/0.433kV S/s- 200 Amp, TPN 36 KA, MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter,Digitaal ammeter and selector switch. |
| 75 | One(1) set of –200/5A , 15VA, CL1.0. CTs |
| 76 | Busbar - 315 Amp Al busbar with SC rating of 36 KA suitable for operation at 415 Volt, 50 Hz, 3 Phase supply. |
| 77 | OUTGOING FEEDERS:- |
| 78 | Two (2) - Outgoing Feeder (For one Pump Room Panel& 1no spare) each comprising of |
| 79 | One (1) -100A,TPN, 25KA,MCCB |
| 80 | One(1)- Digital Ammeter with selector switch |
| 81 | One(1) set of –100/5A, 15VA, CL1.0. CTs |
| 82 | One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. |
| 83 | Three (3) - Outgoing Feeder (For one Auxilliary Pumps MCCP , 1 no Battery Bank with charger & 1no spare) each comprising of |
| 84 | One (1) -63A,TPN, 25KA,MCCB |
| 85 | One(1)- Digital Ammeter with selector switch |
| 86 | One(1) set of –63/5A, 15VA, CL1.0. CTs |
| 87 | One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. |
| 88 | Two (2) - Outgoing Feeders (for 1 no. Feeder Panel for External lighting & 1no. spare) comprising of |
| 89 | One (1) - 63 A,FP, 25KA,MCCB with 63 Amp TP contactor, over load trip, Programmable timer for automatic switching ON and OFF of external lighting, Auto/ Manual selector switch, Auxilliary Contactor, ON/OFF push button and indication along with control fuse etc as required. |
| 90 | One(1) set– Digital Ammeter with selector switch |
| 91 | One(1) set–63/5A , 15VA , CL 1.0, CT |
| 92 | One(1) Set- ON/OFF Indicating lamp with control fuse/ MCB |
| 93 | Two (2) - Outgoing Feeders (for 1 no. Feeder Panel for LED Glow signage board lighting & 1no. spare) comprising of |
| 94 | One (1) - 32 A,FP, 10KA,MCB with 40 Amp TP contactor, over load trip, Programmable timer for automatic switching ON and OFF of external lighting, Auto/ Manual selector switch, Auxilliary Contactor, ON/OFF push button and indication along with control fuse etc as required. |
| 95 | One(1) set– Digital Ammeter with selector switch |
| 96 | One(1) set–32/5A , 15VA , CL 1.0, CT |
| 97 | One(1) Set- ON/OFF Indicating lamp with control fuse/ MCB |
| 98 | Three (3) - Outgoing Feeder for (1 no. HT Panel Room, Rest room etc. L+PDB & 2 no. spares) each comprising of |
| 99 | One (1) 32 Amp. 10 KA DP MCB |
| 100 | PANEL AS ABOVE |
| 101 | Pump Room Panel |
| 102 | One (1)Incomer from MDB - 100 Amp, TPN 25 KA, MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter,Digitaal ammeter and selector switch. |
| 103 | One(1) set of –100/5A , 15VA, CL1.0. CTs |
| 104 | Busbar - 160 Amp Al busbar with SC rating of 36 KA suitable for operation at 415 Volt, 50 Hz, 3 Phase supply. |
| 105 | OUTGOING FEEDERS:- |
| 106 | Two (2) - Outgoing Feeder (For one no. 5 tonne EOT Crane Control panel& 1no. spare) each comprising of |
| 107 | One (1) -63A,TPN, 25KA,MCCB |
| 108 | One(1)- Digital Ammeter with selector switch |
| 109 | One(1) set of –63/5A, 15VA, CL1.0. CTs |
| 110 | One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. |
| 111 | Five (5) - Outgoing Feeder for (1 no. EOT Lighting, 1 no. Starter room L+PDB, 1no. Exhaust system, 1 no. for starter room & 1 no. spare) each comprising of |
| 112 | One (1) 32 Amp. 10 KA FP MCB |
| 113 | PANEL AS ABOVE |
| 114 | Feeder Pillar for External Lighting |
| 115 | Supplying installation testing commissioning of double door (outdoor) feeder pillar fabricated out of 2 mm thick CRCA sheet duly painted, 100 Amp Al busbar with neutral bus including cc/ brick foundation as required including following internal fixtures. |
| 116 | One (1) - 63A,TPN, 25KA,MCCB Incomer |
| 117 | One(1) set of –63 /5A , 15VA , CL 1.0, CT |
| 118 | One Set ON/OFF Indicating lamp with control fuse/ MCB. |
| 119 | 6 Nos - 16 Amp, 10 kA TP MCB Outgoing |
| 120 | 1 No - 16 Amp DP MCB with 6/16 Amp socket outlet with 10 Amp modular switch and 1 No- Bracket Holder with 6 Amp Modular switch. |
| 121 | PANEL AS ABOVE |
| 122 | SITC of 48 V, 150AH Maintenance free VRLA battery (Set of 4 nos. of 12V Battery) |
| 123 | SITC of 48 V Float-cum-Boost Battery Charger & DC Distribution Board for Control Room |
| 124 | Incomer: 63Amp, 10kA Double Pole DC MCCB- 1nos. |
| 125 | Bus bar: 100 Amp, Copper Busbar |
| 126 | Outgoing: 25Amp, Double Pole DCMCB - 12 nos. |
| 127 | CT: 25/1A,CL-1 for metering CTs- 3 nos. |
| 128 | Voltmeter: 0-300V DC - 1nos. |
| 129 | Ammeter: 0-300A DC - 1nos. |
| 130 | Indicator: LED type phase indicating lamps with control fuses - 1set |
| 131 | E. LT Cable, Control Cable, End Termination & Jointing Kit |
| 132 | Supplying, laying & testing of following size of PVC insulated XLPE shethed / striparmoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. |
| 133 | Supply ,Laying ,Testing and Commissioning(SLTC) of 3.5 core x 150 sqmm Aluminum armoured cable. |
| 134 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for3.5 core x 150 sqmm Aluminum armoured cable. |
| 135 | Supply ,Laying ,Testing and Commissioning(SLTC) of 3.5 core x 70 sqmm Aluminum armoured cable. |
| 136 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for3.5 core x 70 sqmm Aluminum armoured cable. |
| 137 | Supply ,Laying ,Testing and Commissioning(SLTC) of 3.5 core x 25 sqmm Aluminum armoured cable. |
| 138 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for3.5 core x 25 sqmm Aluminum armoured cable. |
| 139 | Supply ,Laying ,Testing and Commissioning(SLTC) of 4 core x 16 sqmm Aluminum armoured cable |
| 140 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for4 core x 16 sqmm Aluminum armoured cable |
| 141 | Supply ,Laying ,Testing and Commissioning(SLTC) of 4 core x 10 sqmm Aluminum armoured cable |
| 142 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for4 core x 10 sqmm Aluminum armoured cable |
| 143 | Supply ,Laying ,Testing and Commissioning(SLTC) of 4 core x 6 sqmm Aluminum armoured cable |
| 144 | Supply ,Laying ,Testing and Commissioning(SLTC) of end termination with brass compression gland and aluminium lugs suitable for4 core x 6 sqmm Aluminum armoured cable |
| 145 | Supply ,Laying ,Testing and Commissioning(SLTC) with end termination of 3 core x 2.5 sqmm copper armoured cable |
| 146 | Control Cable |
| 147 | Supplying, laying & testing of following size of PVC insulated XLPE shethed / striparmoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walls / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. |
| 148 | Supply ,Laying ,Testing and Commissioning(SLTC) of 4C, 2.5sqmm, CU armoured FRLS cable through cable trench inside Panel Room |
| 149 | Supply ,Laying ,Testing and Commissioning(SLTC) of 7C, 2.5sqmm, CU armoured FRLS cable through cable trench inside Panel Room |
| 150 | Supply ,Laying ,Testing and Commissioning(SLTC) of 10C, 2.5sqmm, CU conductor, armored, FRLS PVCsheathed Cablethrough cable trench inside Panel Room |
| 151 | Supply ,Laying ,Testing and Commissioning(SLTC) of 1C, 16sqmm, copper conductor, armored, FRLS PVC sheathed Cable through cable trench inside Panel Room |
| 152 | Lightning Protection System, Earthing System & Cable Tray |
| 153 | Lightning Protection System |
| 154 | Providing and fixing of lightning conductor finial, made of 25 mm dia 1000 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 155 | Supply & Jointing of GI tape at base of finial. |
| 156 | Supply & Fixing of GI tape of size20mm X 3mm flat horizontal run direction. |
| 157 | Supply & Fixing of GI tape of size20mm X 3mm flat vertical run direction. |
| 158 | Earthing System |
| 159 | Supply, Installation, testing & Commissioning of Copper plate Earthing (600x600x3mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 160 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. |
| 161 | Providing and fixing 25 mm X 5 mm dia copper strip on wall/surface or in recess for connection etc. as required. |
| 162 | Providing and fixing 4.0 mm dia cu wire on surface or in recess for loop earthing as required. |
| 163 | Supply, Installation, testing & Commissioning of Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 164 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground & open surface as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). |
| 165 | Supplying and laying 6 SWG G.I. wire at existing trench & open surface for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 166 | Cable tray |
| 167 | Supply & installation of following size Ladder typeCable tray with horizontal & vertical bends, reducers, Tee\"s,Cross over, supports, brackets and other accessories as required confirming to IS/IEC-61537.The Cable Ladder shall be made of 1.5mm thick sheet steel upto 600mm.The cable Ladder shall be galvanized for corrosion protection confirming toDIN EN 10346 / ISO 1461 .The cable ladder should be tested for safe working load of minimum 70 Kg/ Mtr with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of 30x15mmm size suitable for fixing the cable clamps the space between the rungs shall be 300mm. etc. complete as required per specifications & approved by the Engineer Incharge. |
| 168 | 450 mm width 50 mm height (2 mm thickness) |
| 169 | 200 mm width 50 mm height (2 mm thickness) |
| 170 | G. Hi Wall Split AC |
| 171 | SITC of 1.50 TR Split A/C with high wall mounted unit including stabiliser (copper wound), insulated copper pipe, outdoor stand, drain pipe including all necessary accessories (BEE 5 Star rated ) |
| 172 | H. External Light Fittings |
| 173 | Supplying, installation testing and commissioning of following type external light fixtures with all accessories as required. |
| 174 | 08 mtr high galvanised Octagonal pole in shape shall be designed to withstand the maximum wind speed as per IS 875. The top loading i.e. area and the weight of fixtures are to be considered to calculate maximum deflection of the pole and the same shall meet the requirement of BSEN 40-3-3:2003. Octagonal Poles made from HT Steel Conforming to grade S355 & having thicknessof 3.1mm.Top dia 70mm & Bottom dia 155mm single sharp welding with base plate dimension250x250x16 mm & Base Plate must be Fe 410 conforming to IS 2062, foundation bolts must EN 8 grade terminal box with provision for connection of earth & neutral on 5mm thick fiber plate which will be kept in side the pole for termination of cable & wire,The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding with round Bracket Suitable for installing 1Nos70 W Bajaj Cat: ENXT P 84L WH PO PC SD MT or Equivalent of Crompton/ Phillips LED IP66 Street Light as required.Warrenty - 5 years onLED luminaire and Warrenty should be given by Manufacturer. |
| 175 | 70 Watt Outdoor LED Luminaires Street Light (6500 lumen)Bajaj(CAT No: ENXT P 84L WH PO PC SD MT) / Equivalent of PHILIPS/ Crompton connected to 32 MM Dia 800 mm GI bend pipe fixed on Wall or column with GI Clamps, internal wiring & hard ware etc. as required. |
| 176 | 40 Watt Gate Light (Make: Bajaj Arian Plus CAT No: BGCTNP40W LED WH/WW or equivalent of Philips/ Crompton) along with loose wire box, connectors with one 10A MCB as required suitable for operation on 240 Volt AC supply as required. |
| 177 | I. Conduits & HDPE Pipes |
| 178 | Supply, delivery and laying of following sizes of 2mm thick PVC Conduit concealed in wall/ column/ roof slab of the building alongwith other accessories and 18 swg GI wire complete for Electrical Wiring/Telephone / TV & Data cable wiring as required and as per direction of Engineer-in-charge. |
| 179 | 20mm dia |
| 180 | 25mm dia |
| 181 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 182 | 50 mm dia (for Gate crossing) |
| 183 | 200 mm dia (for Road crossing) |
| 184 | J. Miscellaneous |
| 185 | Supply & laying of 11KV Grade best quality Rubber Mat. |
| 186 | Endura type 700 Lumen/10W LED Bulkhead wall fitting Crompton (CAT No: LBHE 10 CDL )/ Equivalent of PHILIPS/Bajaj/ Wipro. |
| 187 | Supplying and fixing 3 nos GI fire bucket of 9 ltr capacity with suitable pedastal arrangement for sub-station yard etc as reqd. |
| 188 | Supplying 11 kV hand gloves as reqd. |
| 189 | Supplying of First aid box as approved by St.John Ambulance Brigade/Indian Red Cross Society and confirming to IS 2217/ 1963. |
| 190 | S/F of Shock Treatment chart duly glazed mounted on Aluminum Frame with sheet glass as required. |
| 191 | Supplying of Caution Boards manufactured out of 16 SWG, MS sheet of 450mmx 300mm size duly painted white and having `MAN ON LINE\" and \"DO NOT SWITCH ON\" written in Red complete with hanging arrangement as required and& approved by the Engineer Incharge. |
| 192 | Supply, fixing & testing of indoor type fire extinguiser of suitable grade/composition as per the direction of Engineer-in-Charge |
| 193 | Supply, fixing & testing of 9 ltrs. foam type fire extinguiser |
| 194 | Supply, fixing & testing of 4.5 ltrs. CO2 type fire extinguiser |
| 195 | Supply, fixing & testing of 9 kg dry powder type fire extinguiser |
| 196 | Supply & fixing 3nos of fire bucket with GI stand & GI Canopy (4 buckets/stand) |