Bids Are Invited For Supply Of Ct Pt For Pds At Nmdc Steel Limited 1600054073 Current Transformer, Ratio−300 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec T.Ratio / Alf / Isf<=10, Insuation Class: B, Core-1 7.5 Va Class: 0.5 Core-2: 7.5 Va Class: 5P20.T.Ratio / Alf / Isf=20; For Drawing, Refer Annexure-I. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 2 1600047852 Current Transformer, Ratio−300 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec T.Ratio / Alf / Isf<=10, Insuation Class: B, Core-1 15 Va Class: 0.5 Core-2: 15 Va Class: 5P20.T.Ratio / Alf / Isf=20; For Drawing, Refer Annexure-I. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 3 1600054072 Current Transformer, Ratio−300 / 1 A , Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1 Class: Ps Rct: <=5 Ohm, Vk :325V Ie At Vk / 2 <= 30Ma.; For Drawing, Refer Annexure-I. Standard Is 16227 ( Part2 ) :2016, Iec 61869- 2:2012 / Is 2705, Application: 6.6Kv Ais No 3 4 1600056788 Current Transformer, Ratio−400 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec T.Ratio / Alf / Isf<=10, Insuation Class: B, Core-1 7.5 Va Class: 0.5 Core-2: 7.5 Va Class: 5P20.T.Ratio / Alf / Isf=20; For Drawing, Refer Annexure-I. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 Technical Specification 5 1600047851 Current Transformer, Ratio−250 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20 .; For Drawing, Refer Annexure-I. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 9 6 1600047058 Current Transformer, Ratio−200 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20, Core-2 7.5 Va Class: 0.5 T.Ratio / Alf / Isf<=10, ; For Drawing, Refer Annexure-Ii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 7 1600047057 Current Transformer, Ratio−200 / 1-1 A, Type: Wound Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1: 15 Va Class: 0.5, T.Ratio / Alf / Isf=10, Core-2 15 Va Class: 5P20 T.Ratio / Alf / Isf<=20, ; For Drawing, Refer Annexure-Ii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 8 1600047054 Current Transformer, Ratio−200 / 1, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1 Class: Ps Rct: <= 5Ohm, Vk :325V Ie At Vk / 2 <= 30Ma.; For Drawing, Refer Annexure-Ii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 9 1600047053 Current Transformer, Ratio−125 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10, Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Ii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 Technical Specification 10 1600047051 Current Transformer, Ratio−50 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 9 11 1600047050 Current Transformer, Ratio−50 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 10 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 10 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 12 1600047850 Current Transformer, Ratio−100 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Ii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 6 13 1600047849 Current Transformer, Ratio−950 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 14 1600047847 Current Transformer, Ratio−700 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 No 3 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais 15 1600047846 Current Transformer, Ratio−750 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 16 1600047845 Current Transformer, Ratio−800 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure- V. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 6 17 1600047844 Current Transformer, Ratio−1200 / 1-1 A, Type: Wound, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 18 1600047841 Current Transformer, Ratio−2500 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 Current Transformer, Ratio-2500 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp, Hsv: 12Kv, Stc: 40Ka For 3 Sec, Insuation Class: B, Core-1 Class: Ps, Rct: <= 14Ohm, Vk >=325V, 19 1600047839 Ie At Vk / 2 <= 30Ma, Core-2: Class: Ps, Rct: <= 14Ohm, Vk >=325V, Ie At Vk / 2 <= 30Ma.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 Technical Specification 20 1600047049 Current Transformer, Ratio−2000 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 1 Sec Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 21 1600047048 Current Transformer, Ratio-2000 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp, Hsv: 12Kv, Stc: 40Ka For 3 Sec, Insuation Class: B, Core-1 Class: Ps, Rct: <= 14Ohm, Vk >=325V, Ie At Vk / 2 <= 30Ma, Core-2: Class: Ps, Rct: <= 14Ohm, Vk >=325V, Ie At Vk / 2 <= 30Ma.; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 22 1600047771 Current Transformer, Ratio-3150 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp, Hsv: 12Kv, Stc: 40Ka For 3 Sec, Insuation Class: B, Core-1 Class: Ps, Rct: <= 14Ohm, Vk >=325V, Ie At Vk / 2 <= 30Ma, Core-2: Class: Ps, Rct: <= 14Ohm, Vk >=325V, Ie At Vk / 2 <= 30Ma.; For Drawing, Refer Annexure-Vi. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 6 23 1600047770 Current Transformer, Ratio-3150 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp, Hsv: 12Kv, Stc: 40Ka For 3 Sec, Insuation Class: B, -Type: Window Insuation Class: B Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 9 Current Transformer, Ratio−1250 / 1-1 A, Type: Window, Resin Cast, Indoor, 24 1600047769 Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec Insuation Class: B, Core-1 Class: Ps Rct: <= 5Ohm, Vk :325V Ie At Vk / 2 <= 30Ma Core-2: Class: Ps Rct: <= 5Ohm, Vk :325V Ie At Vk / 2 <= 30Ma . ; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 25 1600047768 Current Transformer, Ratio−1250 / 1-1 A, Type: Window, Resin Cast, Indoor, Il: 12 / 28 / 75 Kvp Hsv: 12Kv Stc: 40Ka For 3 Sec T.Ratio / Alf / Isf<=10, Insuation Class: B, Core-1 7.5 Va Class: 0.5, T.Ratio / Alf / Isf<=10 Core-2: 7.5 Va Class: 5P20, T.Ratio / Alf / Isf=20; For Drawing, Refer Annexure-Iv. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 3 26 1600047767 Current Transformer, Ratio−600-300 / 1-1 A, Type-Window, Resin Cast, Indoor, Ref: Cr393 Il: 28 / 75 Kvp Hsv: 12Kv Str: 40Ka For 3 Sec Insuation Class: B, Core-1: 300 / 1A, 7.5 Va / 0.5, T.Ratio / Alf / Isf<=10 600 / 1 A, 7.5 Va / 0.5 Core-2: 300 / 1A, 7.5 Va / 5P20, 600 / 1 A, 7.5 Va / 5P20, T.Ratio / Alf / Isf=20; For Drawing Refer Annexure-Vii. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 6.6Kv Ais No 6 27 1600048329 Current Transformer, Resin Cast, Indoor, Ratio 300 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 2R-3C-185;, Type:2 ; For Drawing, Refer Annexure-Ix. Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 Current Transformer, Resin Cast, Indoor, Ratio 300 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, 28 1600048447 Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 1R-3C-240;, Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 Technical Specification 29 1600048446 Current Transformer, Resin Cast, Indoor, Ratio 350 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5, Isf<10; Core- Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Cable: 2R-3C-300;Ins. Level:0.72 / 3 / 10Kvp, Ins. Class B, Stc ( Min. ) :40 Ka / 1 Sec; Type:2; For Drawing, Refer Annexureix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 30 1600050121 Current Transformer, Resin Cast, Indoor, Ratio 450 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Rsec At 75 Deg Celcius <=3 Ohm, Insulation Level 3 Kv, Hsv:0.66 Kv, Un, 50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore , Cable: 2R-3C-300;, Type:2; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 31 1600050119 Current Transformer, Resin Cast, Indoor, Ratio 600 / 1-1 A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 2R-3C-185, Type:2, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 32 1600053808 Current Transformer, Resin Cast, Indoor, Ratio 800 / 1-1A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20;Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore , Cable: Nil, Type:5; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 33 1600053807 Current Transformer, Resin Cast, Indoor, Ratio 800 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 3R-1C-630 With Sa, Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 34 1600054083 Current Transformer, Resin Cast, Indoor, Ratio 800 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore, Cable : 3R-3C-300, Type:4, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 35 1600053805 Current Transformer, Resin Cast, Indoor, Ratio 1000 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core-Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm Cable: 2R-1C630, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 36 1600053804 Current Transformer, Resin Cast, Indoor, Ratio 1250 / 1-1A; Core-I: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm;Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore, Cable: Nil, Type:5; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 37 1600054010 Current Transformer, Resin Cast, Indoor, Ratio 1250 / 1-1A; Core-I: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm;Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 3R-3C-300, Type :4, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 38 1600054009 Current Transformer, Resin Cast, Indoor, Ratio 1250 / 1-1A; Core-I: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 3R-1C-630, Type :1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 39 1600054007 Current Transformer, Resin Cast, Indoor, Ratio 1250 / 1-1-1A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20;Core-Iii Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore, Cable: 1R-1C-630 Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 40 1600054005 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20, Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore;Cable: Nil, Type:5, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, 41 1600048328 Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 3R-3C-630 Type:4, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 Technical Specification 42 1600048327 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1-1 A; Core-I: 7.5 Va Cl 0.5; Core- Ii 7.5Va Cl 5P20; Core-Iii: Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm, Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore Cable: 3R-1C-630. Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 43 1600054003 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1 A; Core-I:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; . Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore;Cable: 3R-1C-630 . Type:1, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 44 1600054002 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1 A; Core-I:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; . Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore; Cable:2R-3C-300. Type:2, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 45 1600054000 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1 A; Core-I:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; . Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore; Cable:2R-1C-630. Type:3, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 46 1600053999 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1 A; Core-I:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; . Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; Primary:Pass Bar Through Bore; Cable: 3R-3C-300. Type:4, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis No 3 47 1600047842 Current Transformer, Resin Cast, Indoor, Ratio 2000 / 1-1 A; Core-I:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3Ohm; Core-Ii:Ps, Min Vk ≥325V, Img=30Ma At Vk / 2, Rct<=3 Ohm; . Insulation Level:0.66 / 3Kv, Insulation Class: E, Freq:50 Hz, Stc ( Min. ) :40Ka For 1 Sec; No 3 Primary:Pass Bar Through Bore; Cable:9R-1C-630 . Type:5, ; For Drawing, Refer Annexure-Ix . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 2705, Application: 33Kv Gis 48 1600047736 Single Ph , Single Pole Pt , Resin Cast, Indoor, Type- Earthed Ratio6600 / R3 / 110 / R3 / 110 / 3V, 7.2 / 20 / 60 Kvp, V.F. : 1.2 Cont. & 1.9 For 8 Hrs. Freq-50 Hz, Phase1, Insulation Class-B Wdg.I- Output&Cl- 50Va , Cl- 0.5 / 3P Wdg.Ii- Output&Cl- 50Va, Cl-3P.; For Drawing, Refer Annexure-Viii . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 3150, Application: 6.6Kv Ais No 3 49 1600047733 Single Ph , Single Pole Pt , , Resin Cast, Indoor, Type- Earthed Ratio11000 / R3 / 110 / R3 / 110 / 3V, 7.2 / 20 / 60 Kvp, V.F. : 1.2 Cont. & 1.9 For 8 Hrs. Freq-50 Hz, Phase1, Insulation Class-B Wdg.I- Output&Cl- 50Va , Cl- 0.5 / 3P Wdg.Ii- Output&Cl- 50Va, Cl-3P.; For Drawing, Refer Annexure-Viii . Standard Is 16227 ( Part2 ) :2016, Iec 61869-2:2012 / Is 3150, Application: 11Kv Ais Total Quantity : 177