|
| 1 | Providing and fixing C.Isluice valves (with cap) completewith bolts, nuts, rubber incertion etc. (the tail pieces if required will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. |
| 2 | ii) 100 mm dia. PN- 1.6 |
| 3 | ii) 150 mm dia. PN- 1.6 |
| 4 | Providing and fixing C.I. non-return valve of approved quality asperCPWD specification and direction of the Engineer - in - charge.(i) 80mm nominal bore |
| 5 | ii) 100 mm nominal bore |
| 6 | iii) 150 mm nominal bore |
| 7 | Providing and fitting fixing of 3 pole power contactors Type ML(standard coil voltageAC-3 Duty, 415 V, 50 Hz, Motor Rating AC-3 Duty, 415 V, 50 Hz, 3Ph) of L&T Makeas per direction of Engineer - in - charge. |
| 8 | a) Type ML2 AC3 Rating(A) 32, AC1 Rating(A) 40, Aux Contacts 2NO+2NC Cat No.SS90701 |
| 9 | Supplying and fitting fixing of 3 pole power contactorsof ML3 Type, 40 amps rating, cat No.ss90721 suitable for 3 PH fully Automatic Star Delta starter of L&T Makeas per direction of the Engineer - in - charge. |
| 10 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter(3 ph, 50 Hz, 415V) in steel sheet enclosures with contractors and timer etc. complete suitable for submersible pump L&T, BCH , ABB make as per specification and direction of the Engineer - in - charge. |
| 11 | ii)35 HP/26 kw Relay range within 20-32 +10% |
| 12 | 50 HP/37 kw Relay range within 28-42 + 10% |
| 13 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge. |
| 14 | (ii) 100 amps |
| 15 | Rewinding of Motor suitable V.T. pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 16 | ii)25 - 30 HP |
| 17 | iv) 50-65 HP |
| 18 | v) 75 - 90HP |
| 19 | Repair and maintenance of 20/22.5HPMotor suitable for 10000 GPH capacity submersible pump set by complete dismantling in/c providing & fitting fixing of PVC (IS: 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 20 | Repair and maintenance of 10 Hp/12.5 HP Motor suitable for 5000 GPH capacity submersible pumpset by complete dismantling in/c providing & fitting fixing of PVC (IS : 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer- in -charge. |
| 21 | Repair and maintenance of 15 Hp/17.5 HP Motor suitable for 7500 GPH capacity submersible pumpset by complete dismantling in/c providing & fitting fixing of PVC (IS : 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer- in -charge. |
| 22 | Repair and maintenance of 30 HP Motor suitable for 15,000 GPH capacity submersible pumpset by complete dismantling in/c providing & fitting fixing of PVC (IS : 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer- in -charge. |
| 23 | Repair and maintenance of 35/40 HP Motor suitable for 20,000 GPH capacity submersible pumpset by complete dismantling in/c providing & fitting fixing of PVC (IS : 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer- in -charge. |
| 24 | Repair and maintenance of submessible Motor suitable for submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electrograde copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 25 | ii) 1.0 HP Motor suitable for 1000 GPH capacity submerssible pumpset |
| 26 | iv) 2.0 HP Motor suitable for 2000 GPH capacity submerssible pumpset |
| 27 | Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and eassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 28 | iii) 3.0-5.0 HP |
| 29 | iv)7.5 - 10 HP |
| 30 | Providing and instsllation of 10,000 GPH X 76 mtrs.head water lubricated vertical submersible pumpkirloskar/ WPL / KSB / Duke / Texmo make ). With maximum 8(eight) stages coupled with required wet and non - over loading submersible motor suitable for 340=440 Volts, 3 Phase, 50 Hz, AC supply and star delta method of starting as per direction of the Engineer in charge. |
| 31 | Providing and instsllation of 7500 GPH X 76 mtrs.head water lubricated vertical submersible pump(kirloskar/ WPL / KSB / Duke / Texmo make ). With maximum 7(seven) stages coupled with required wet and non - over loading submersible motor suitable for 340-440 Volts, 3 Phase, 50 Hz, AC supply and star delta method of starting as per direction of the Engineer in charge. |
| 32 | Providing and instsllation of 5000 GPH X 76 mtrs.head water lubricated vertical submersible pumpkirloskar/ WPL / KSB / Duke / Texmo make ). With maximum 8(eight) stages coupled with required wet and non - over loading submersible motor suitable for 340=440 Volts, 3 Phase, 50 Hz, AC supply and star delta method of starting as per direction of the Engineer in charge. |