Tender For Repair To Z.P. Prashala At Sonari Tal.Paranda As Per Boq. 1 Removing Cement Tiles, Or Marble Or Polishedshahabad Floor Or Dado Without Bed Concrete Including Stacking The Materials As Directed With All Leads, Lifts Etc. Complete 2 Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall Leads, Lifts Etc. Complete. 3 Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceandstacking The Debris Upto A Distance Of 50 Metres Or Spreading In The Compound And Cleaning The Site Etc. Complete. 4 Excavation For Foundation In Earth, Soil Of All Types, Sand, Gravel And Soft Murum, Including Removingtheexcavatedmaterialuptoadistanceof50m.Beyondthebuildingareaand Stackingandspreadingasdirected, Dewatering, Preparingthebedforthefoundationand Necessary Back Filling, Ramming, Watering Including Shoring And Strutting Etc. Complete. ( Lift Upto 1.5 M. ) By Mechanical Means 5 Excavationforfoundationinhardmurum Includingremovingtheexcavatedmaterialupto Distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, Dewatering, Preparingthebedforthefoundationandnecessarybackfilling, Ramming, Wateringincludingshoringandstruttingetc.Complete. ( Liftupto1.50M ) Bymechanical Means 6 Providingandlayingcastinsitu / Readymixcementconcreteinm-10Oftrap / Granite / Quartzite / Gneissmetalforfoundationandbeddingincludingbailingoutwater, Steel Centering, Formwork, Laying / Pumping, Compacting, Roughening Them If Special Finish Is To Be Provided, Finishingifrequiredandcuringcomplete, Withfullyautomaticmicroprocessor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete.With Fine Aggregate ( Crushed Sand Vsi Grade ) 7 Providing And Laying In Situ / Ready Mixcement Concretem-20Of Trap / Granite / Quartzite / Gneiss Metalforr.C.C.Work Infoundationslikeraft, Stripfoundations, Grillageand Footingsofr.C.C.Columnsandsteelstanchions Etc.Includingbailingoutwater, Steel Centeringformwork, Laying / Pumpingcoverblocks, Compactionandcuring Roughening The Surface If Special Finish Is To Be Provided ( Excluding Reinforcement And Structural Steel ) Etc. Complete, With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 8 Providingandlayingcastinsitu / Readymixcementconcretem-20Oftrap / Granite / Quartzite / Gneiss Metal For R.C.C. Columns As Per Detailed Designs And Drawing Or As Directed Including Steel Centering, Formwork, Cover Blocks, Laying / Pumping, Compaction Finishing The Formed Surfaces With Cement Mortar 1:3 Of Sufficient Minimum Thickness To Give A Smooth And Even Surface Or Roughening If Special Finish Is To Be Provided And Curing Etc. Complete, ( Excluding Reinforcement And Structural Steel ) .With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 9 Providingandlayingcastinsitu / Readymixcementconcretem-20Oftrap / Granite / Quartzite / Gneiss Metal For R.C.C. Beams And Lintels As Per Detailed Designs And Drawings Or Asdirectedincludingsteelcentering, Formwork, Coverblocks, Laying / Pumping, Compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. Complete. ( Excluding Reinforcement And Structural Steel ) . With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 10 Providingandlayingcastinsitu / Readymixcementconcreteinm-20Oftrap / Granite / Quartzite / Gneiss Metal For R.C.C.Coping To Plinth Or Parapet And Sill Of Doors And Windows Moulded As Per Detailed Drawings Or Chamfered As Approved By The Engineer Including Steel Centering, Formwork, Coverblocks, Laying / Pumping, Compacting, Curing, Finishingand Rougheningthemifspecialfinishistobeprovidedandcuringcomplete. ( Excluding Reinforcementandstructuralsteel ) .Withfullyautomaticmicroprocessorbasedplcwith Scadaenabledreversibledrumtypemixer / Concretebatchmixplant ( Panmixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 11 Providing Secondclassburntbrickmasonrywithconventional / I.S.Typebricksincement Mortar 1:6 In Foundations And Plinth Of Inner Walls / In Plinth External Walls Including Bailing Out Water Manually , Striking Joints On Unexposedfaces, Raking Out Joints On Exposedfaces And Watering Etc. Complete. 12 Providing Secondclassburntbrickmasonrywithconventional / I.S.Typebricksincement Mortar1:6Insuperstructureincludingstrikingjoints, Rakingoutjoints, Wateringandscaffolding Etc. Complete 13 Providing And Fixing In Position Tmt - Fe - 500 Bar Reinforcement Of Various Diameters Forr.C.C.Pilecaps, Footings, Foundations, Slabs, Beamscolumns, Canopies, Staircase, Newels, Chajjas, Lintelspardis, Copings, Fins, Archesetc.Asperdetaileddesigns, Drawingsand Schedules. Including Cutting, Bending, Hooking The Bars, Binding With Wires Or Tack Welding And Supporting As Required Complete. 14 Filling In Plinth And Floors With Contractorsmaterial / Brought From Outside And Approved By Engineerincharge Inlayersof15cm To20cmincludingwateringandcompactionetc.Complete. 15 Providinginternalcementplaster12mm Thickinsinglecoatincementmortar1:5Without Neeru Finish To Concrete Or Brick Surfaces, In All Positions Including Scaffolding And Curing Etc.Complete. 16 Providing Internal Cement Plaster 20Mm Thick Insingle Coats In Cement Mortar 1:5Withoutneeru Finish, To Concrete, Brick Surface, In All Positions Including Scaffolding And Curing Etc. Complete 17 Providing Sand Faced Plaster Externally In Cement Mortar Using Approved Screened Sand, In All Positionsincludingbasecoatof15mmthickincementmortar1:4Usingwaterproofing Compound At 1Kilogramper Cement Bag Curing The Same For Not Less Than 2 Days And Keeping Thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm Thickin Cementmortar1:4Finishingthesurfacebytakingoutgrainsandcuringforfourteendays Scaffolding Etc.Complete. 18 Providing And Fixing Steel Window C.R.C. Sheet As Per I.S. 1513 : 1986. Gauge Sect. 65 X 40 X 25 Mm Shutter Single Sheet Of 24 Gauge Single Leaf Joinedby Fusion Welding At Appropriate Points With Vertical Grooves Of 15 Mm Wide And 15 Mm Deep At A Distance Of 45 Mm. The First Andlastribshouldbe60mmawayfromverticaledgeoftheshutter.Theshuttershallbe Welded, With Angle To From The Periphery Of The Shutter. At The Center Of The Frame There Shall Beangleweldedtobifurcatetheframeintosegmentswithtwoleafshuttersquare12mm Square Guard Bars At 120 Mm Center With All Accessories 19 Providing And Fixing M.S. Grill Door 24 Kilogram / Square Metre Of Various Size As Per Detailed Drawings Without Hot Dip Coating, Iron Fixtures And Fastenings And 3 Coats Of Oil Painting Etc. 20 Providing And Laying Rough Shahabad Stone Flooring 25Mm To 30Mm Thick And Of Required Width In Plain / Diamond Pattern On A Bed Of 1:6 C.M. Including Cement Float, Striking Joints, Pointing In Cement Mortar 1:3 Curing And Cleaningetc. Complete. 21 Providing And Laying Vitrified Matt Fininsh Tileshaving Size 590 Mm To 605 Mm X To 605 Mm Of8to10mmthicknessandconfirmingis.15622-2006 ( Groupbla ) Ofapprovedmake, Shadeandpatternforflooringinrequiredpositionlaidonabedof1:4Cementmorar Including Neat Cement Float, Filling Joints, Curing And Cleaning Etc. Complete. 22 Providing And Laying Vitrified Matt Finish Tileshaving Size 590 Mm To 605 Mm X To 605 Mm Of8to10mmthicknessandconfirmingis.15622-2006 ( Groupbla ) Ofapprovedmake, Shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4Cementmortar Including Neat Cement Float, Filling Joints, Curing And Cleaning Etc. Complete. 23 Providing Andfixing Colourcoatedzincalume ( R ) Az150 ( Min150gms / Sq.Mt.Totalon Each Side ) Profiled Sheets For Roofing. The Feed Material Is Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness ( Bmt ) ( 0.5 Mm Tct ) , Hi-Strength Steel With Min.550 Mpa Yield Strength, Metallichotdipcoatedwithaluminium-Zincalloy ( 55%Aluminium 43.4%Zinc 1.6% Silicon ) With Colorbond ( R ) Steel Quality Super Durable Polyester Paint Coat ( With Inorganicpigment ) .Thepaintshallhaveatotalcoatingthicknessofnominal35um, Comprising Of Nominal 25 Um Exterior Coat On Top Surface And Nominal 10 Um Reverse Coat On Back Surface. Profile Sheet Shall Have Nom. 950-1050 Mm Effective Cover Width And Nominal 25-30 Mm Deep Ribs With Subtle Square Fluting In The Five Pan At Nominal 180-250 Mm Center- To-Center.The Endribshallbedesignedforanti-Capillarygroove.Andreturnleg.Thefeed Material Should Have Coil Manufacturers Product Details Marked A Regular Interval. Including Fasteners With Min. Fastened With Min. 25 Um Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw Etc. Complete. ( Weight Of Profile 4.52 Kilogram / Square Metre ) 24 Providing And Fabricating Structural Steel Work In Rolled Sections Like Joists, Channels, Angles, Teesetc.Asperdetaileddesignanddrawingsorasdirectedincludingcutting, Fabricating, Hoisting, Erecting, Fixinginpositionmakingriveted / Bolted / Weldedconnectionswithout Connecting Plates, Braces Etc. Andincluding One Coat Of Anticorrosive Paint Andover Ittwo Coats Of Oil Painting Of Approved Quality And Shade Etc. Complete. 25 Providing And Applying Two Coats Of Lead / Zinc Base Oil Paint / Bituminious Paint Of Approved Colourtonewstructuralsteelworkandironworkinbuildingsincludingscaffoldingif Necessary, Cleaning And Preparing The Surface Etc.Complete. ( Excluding Primer Coat ) . 26 Providing And Applying Two Coats Of Exteriorweather Shield Paint Of Approved Manufacture Andofapprovedcolourtotheplasteredsurfacesincludingcleaning, Preparingtheplaster Surface , Applying Primer Coat , Scaffolding If Necessary, And Watering The Surface For Two Days Etccomplete.Note: Foritem Number 15 To 18 Prior Approval Of Superintending Engineer Will Be Necessary 27 Providing And Applying Washable Oil-Bound Distemper Of Approvedcolour Andshade To Old Andnewsurfaces In Two Coats Including Scaffolding, Preparing The Surfaces. ( Excluding The Primer Coat. ) Etc. Complete. 28 Providingandfixingboarddisplayinginformation, SuchasNameofwork, Tendercost, Name Of Contractor, Work Completion And Liability Period Etc, Having Rectangular Shape Of 1.20M X 0.90M Size Made Out 18 Gauge ( 1.25Mm ) Thick Mild Steel Sheet Painted With One Coat Of Zinc Chromate Stoving Primer And Two Coats Of Enamel Paint On Front Side And Grey Stove Enamel On Back Side And Border / Messages / Symbols Etc. With Approved Colour Shade Paint Complete, On M.S.Angle Of Size 35 X 35 X 3 Mm Frame With Properly Cross Braced M.S. Angles Of Size 35Mmx35mmx3mm Duly Painted Including Two M.S. Angle Iron Posts Of Size 65 Mm X 65 Mm X 6 Mm, 3.65 M Long Painted With Alternate Black And White Bands Of 25 Cm Width Including All Fixtures Etc.And Fixing The Boards In 1:4:8 Concrete Block Of Size 60 Cm X 60 Cm X75cmincluding, Excavation, Refilling, Transportation, Andlabouretccomplete.Spec. Number As Directed By Engineer In Charge 29 Charges For Testing Of Material In Vilgilance & Quality Control Laboratory Etc Complete For Concrete Compressive Stength ( Set Of 3 Cubes ) 30 For Metal Sieve Analysis 31 Ceramic Tiles / Vitrified Tileswater Absorption, Modules Of Rapture ( Set Of 6 Tiles ) 32 Royalty Charges For Supply Of Soil 40Mm / 80Mm Metal ( Hand Broken )